Previous
Next
Share
Free Delivery in India | Lowest Global Shipping Charges
24/7 Customer Support
24/7 Customer Support

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

24/7 Customer Support
Save up to 28% with GST Input

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

Lowest Price Challenge
# Lowest Price Challenge

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Lowest Price Challenge
100% Original Products

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase

Hanna Spare ORP Electrode for Testers - HI73120

Category ORP Electrodes Brand Hanna Condition New

Specifications

Country of Origin India
Measurement Range ±2000 mV
Body Material polypropylene
Model HI73120
Temperature Sensor no
Max. Pressure 0.1 bar
Connector Type Pin
Reference Cell Type Single, Ag/AgCl
Tip / Shape Platinum pin
Temperature Operating Range -5 to 50 °C
Amplifier no
Recommended Use Field applications, general purpose
Compatibility HI98120 ORP Tester
Junction Type Cloth
Electrode Type Spare ORP Electrode
Product Condition New
MPN HI73120
Electrolyte Type Gel
Temperature Operating Range (F) 23 to 122 °F

Key Features

HI73120 Spare ORP Electrode for Testers designed for compatibility with HI98120 ORP Tester, featuring a robust polypropylene body and platinum pin tip for reliable ORP measurements in industrial and laboratory environments.

  • Easy-fit cartridge design ensures simple and secure installation.
  • Polypropylene body provides enhanced durability for field applications.
  • Features a watertight seal with dual O-rings for reliable operation.
  • Measurement range supports ORP values up to ±2000 mV.
  • Cloth junction and gel electrolyte minimize maintenance needs.
  • Single Ag/AgCl reference cell for stable readings.
  • Applicable for field and general-purpose usage.

Product Description

HI73120 Spare ORP Electrode for Testers is designed for seamless compatibility with the HI98120 ORP Tester, making it an ideal replacement electrode for accurate oxidation-reduction potential measurements. With a rugged polypropylene body and platinum pin tip, this easy-fit cartridge locks securely in place and ensures repeatable results in both field and general laboratory applications.

The easy-install design incorporates two O-rings to provide a watertight seal, maximizing durability in harsh or wet environments. The HI73120 operates within a wide ORP range of ±2000 mV and a temperature range of -5 to 50°C, supporting professional water analysis, industrial process monitoring, and routine laboratory testing. The cloth junction and gel electrolyte system enable reliable, maintenance-friendly performance, while the single Ag/AgCl reference cell ensures stable measurement stability throughout usage.

  • Cartridge-style spare ORP electrode suitable for HI98120 ORP Tester.
  • Durable polypropylene housing withstands challenging field environments.
  • Platinum pin tip provides precise and responsive ORP detection.
  • Dual O-ring seal ensures watertight integrity.
  • Gel-filled, maintenance-free electrolyte with a cloth junction design.
  • Stable Ag/AgCl single reference cell increases reading consistency.
  • Supports a measurement range up to ±2000 mV for comprehensive testing applications.
  • Designed for quick and secure replacement in industrial, water treatment, and laboratory settings.

This electrode is suited for industrial, environmental, water treatment, and laboratory applications requiring reliable, easy-to-replace ORP sensors. For more options regarding laboratory accessories, electrodes, and water quality analysis solutions, explore the Sensors and Laboratory Instruments categories on EnvMart.

Comments (0)

Frequently Asked Questions

The HI73120 ORP Electrode is designed for seamless compatibility with the HI98120 ORP Tester, making it an ideal replacement for accurate ORP measurements.

The electrode features a durable polypropylene body and a platinum pin tip, ensuring reliable performance in both industrial and laboratory settings.

The HI73120 electrode has an easy-fit cartridge design that allows for simple and secure installation, making replacement quick and hassle-free.

The HI73120 ORP Electrode supports a measurement range of up to ±2000 mV, suitable for various testing applications.

Yes, the HI73120 electrode is designed with a rugged polypropylene body, making it suitable for challenging field environments and reliable performance.

The electrode features a gel-filled, maintenance-free electrolyte with a cloth junction design, minimizing maintenance needs while ensuring reliable performance.

The HI73120 ORP Electrode operates effectively within a temperature range of -5 to 50°C, suitable for various environmental conditions.

The dual O-ring seal provides a watertight integrity, enhancing the durability of the electrode in harsh or wet environments.

The HI73120 electrode is ideal for industrial, environmental, water treatment, and laboratory applications requiring reliable ORP measurements.

You can purchase the HI73120 ORP Electrode directly through our website. For further inquiries, feel free to contact our support team.

Related Products

$92.42
$89.65 Save 3%
Tax included
Quantity
Delivery Time Delivered within 0-3 days
  • Genuine Products   
  • Global Shipping 
  • Secured Payments
$92.42
$89.65
Tax included