Previous
Next
Share
Free Delivery in India | Lowest Global Shipping Charges
24/7 Customer Support
24/7 Customer Support

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

24/7 Customer Support
Save up to 28% with GST Input

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

Lowest Price Challenge
# Lowest Price Challenge

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Lowest Price Challenge
100% Original Products

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase

Serinus 31 Carbon Dioxide (CO2) Analyser

SKU AAAEP Category Gas Analyzer Brand Acoem

Specifications

Country of Origin India
Warranty As per Manufacturer

Key Features

  • Extended measurement ranges
  • External AC powered pump (capable of operating 3 analysers, excluding NOX)
  • Internal long life, low power maintenance free pump (Max 6 watts)
  • Dual filter (particulate), High pressure zero/span valves, Rack slides
  • TCP/IP network port •

Product Description

The Serinus 31 carbon dioxide (CO2) analyser uses non-dispersive infrared (IR) gas correlation spectroscopy to provide accurate, stable, and repeatable measurements of gaseous CO2.The Serinus 31 can be configured to operate in absolute or differential mode providing flexibility within the analyser, making it well suited for ambient CO2 measurements in addition to applications such as dilution extractive stack monitoring.APPROVALSSimilar in design to the Serinus 30 Carbon Monoxide analyser,this instrument has the following approvals: US EPA approval (RFCA0509174) EN approval (TV 936/21221977/D) Non Dispersive I.R. Spectrometry method EN1426 Russian approval (56262-14) French approval LSCQA Ukraine approval (12/3/B/24/295-17) Chinese Pattern Approval (JJF1364-2012) Korean approval NIER (AACMS-2017-02)BENEFITSThe Serinus range of analysers has been designed using ourexperience and knowledge gained from operating large airquality monitoring networks for nearly 50 years. The resultis instruments that integrate seamlessly into continuousmonitoring networks. Guaranteed performance with a 2 year warranty Superior remote instrument control, diagnostic viewing &calibration minimise on-site maintenance requirements Comprehensive data logging & remote viewing of over 200operational parameters Versatile interfacing through RS232, USB, Bluetooth, analog &digital I/O & optional TCP/IP Easier setup through an intuitive menu system with QuickMenu, advanced GUI & a large keypad with tactile keys Instant display of operational status using illuminated trafficlights on the front panel Removable flash memory stores 10 years of data, includingup to 12 individual parameters & event logs. Operationalparameters can also be transferred to memory for easyretrieval Install latest firmware updates via the USB flash memory drive Easily program, view, download & email data using Bluetoothconnectivity combined with the Serinus Remote app from theGoogle Play store 12 VDC internal voltages for enhanced operator safety Standard components across the Serinus range reduces thecost of spare parts, accessories & consumables Rack slide design makes accessing internal components &removing the analyser from a rack cabinet easy Choose either an external sample pump suitable for use bymultiple analysers or the optional low power internal pump forgreater sample versatility Lower power demand & ability to operate over a widetemperature range reduce AQMS power usage.DATA LOGGING 8 GB removable USB flash memory drive that stores the internaldata logger, event log, automatic/manual configuration backupand automatic/manual parameter list save Internal data logger (can log up to 12 of 200+ parameters) Logger interval (1 second to 24 hours) Storage capacity ~ 10 years (set to 1 minute interval).OPTIONS & ACCESSORIES Internal Sample Dryer TCP/IP Network Port Dual Sample (particulate) Filter High Pressure Span (for direct cylinder calibration) High Pressure Zero (for direct cylinder calibration) Test Lamp (for PMT diagnostics) Metric Fitting Kit (to connect 6 mm tube to rear ports) 19 Rack Mount Kit External Pump (240 or 110 VAC) External Charcoal Scrubber Annual Maintenance Kit Trace Level Option High Level Option Printed User Manual (a soft copy of the user manual is supplied onthe ACOEM Ecotech resources USB stick with each analyser).COMMUNICATION #1 RS232 port (supports all protocols*) #2 RS232 port (supports all protocols* and multidrop) USB port (Advanced protocol only) Bluetooth (Advanced protocol only) TCP/IP network port (optional, supports all protocols*).*Available protocols: Modbus (RTU/TCP), Bayern Hessen, EC9800 or AdvancedCOMMUNICATION ANALOG & DIGITAL I/O PORT: 3 x analog outputs (current or voltage), 12 bit resolution userdefinable range (between two user specified points)Current range: 0 - 20 mA, 2 - 20 mA or 4 - 20 mAVoltage range: 0 - 5 V, 0 - 10 V (voltage offset of 0 V, 0.25 V or 0.5 V) 3 x analog inputs (scalable), 0 - 5 V, 16 bit resolution 8 x logic level digital control inputs 8 x open collector digital status outputs.
  • Printed manual – electronic manual supplied with analyser
  • Bluetooth connectivity combined with the Ecotech Serinus® Remote Android App makes it even easier to program, maintain, download and email data without touching the instrument.

Comments (0)

Frequently Asked Questions

The Serinus 31 CO2 Analyser features extended measurement ranges, an external AC powered pump, an internal low power maintenance-free pump, dual particulate filters, high pressure zero/span valves, and a TCP/IP network port.

It uses non-dispersive infrared (IR) gas correlation spectroscopy to provide accurate and stable measurements of gaseous CO2.

The Serinus 31 comes with a warranty as per the manufacturer's terms, ensuring reliable performance.

Yes, it can be configured to operate in absolute or differential mode, making it suitable for both ambient CO2 measurements and dilution extractive stack monitoring.

It features an internal data logger that can log up to 12 of over 200 parameters, with a storage capacity of approximately 10 years at a 1-minute interval.

Yes, it is designed to integrate seamlessly into continuous monitoring networks, benefiting from nearly 50 years of experience in air quality monitoring.

The analyser supports multiple communication options including RS232, USB, Bluetooth, and an optional TCP/IP network port.

The rack slide design allows for easy access to internal components, making maintenance straightforward.

The internal pump operates at a maximum of 6 watts, and the analyser is designed for lower power demand, enhancing energy efficiency.

For further inquiries or support, please contact our customer service team or visit our website for additional resources.

Related Products

$11.59
Tax included
Quantity
Delivery Time Delivered within 0-3 days
  • Genuine Products   
  • Global Shipping 
  • Secured Payments
$11.59
Tax included