Previous
Next
Share
Free Delivery in India | Lowest Global Shipping Charges
24/7 Customer Support
24/7 Customer Support

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

24/7 Customer Support
Save up to 28% with GST Input

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

Lowest Price Challenge
# Lowest Price Challenge

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Lowest Price Challenge
100% Original Products

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase

Oil in Water Monitor For Hydrocarbons

SKU AAKMG Category Water Analyzer Brand Potence Condition New

Specifications

Power Requirement 100240 VAC 50/60 Hz| 1.3 A max 1 phase| neutral or hot (inrush current not to exceed 40 A max)
Applications Steam condensate| boiler feed water| cooling water| intake protection| dam sumps| process optimization
Principle Ultraviolet fluorescence
Hydrocarbons Diesel| fuel oil| crude oil| gasoline| jet fuel| lubricating oils| phenol| heat transfer fluids| aromatic chemicals

Key Features

  • UV Fluorescence Low ppb – 6000 ppm (dependent on oil Solubility in water) 32-122°F(0-50°C) Configurable early, high system, Cell condition, High Temperature 4-20mA isolated, selectable loop or instrument powered Optional: HART

Product Description

The TD-120 Oil in Water Monitor is resistant to dirty or turbid water influences that typically impact UV absorption or light scatter instrument measurementsallowing hydrocarbons, fuels, lubricating oils, heat transfer fluids, and crude oil to be measured at low ppm/ppb levels. Turner Designs Hydrocarbon Instruments has been theworld leader in oil in water monitoring for more than 20years. The TD-120 Oil in Water Monitor was developedbased on our extensive real-world experience and offersUV fluorescence technology with industry leading features.The TD-120 is available with either a standard care packageor custom care package to match the needs of your siteconditions and application. The customer care packagesinclude calibration to known standards or calibration toyour target hydrocarbon, using sample analysismakingyour installation and start-up process trouble free. TheTD-120 is ideal for detection of oil leaks and spills for heatexchangers, boilers, and membrane systems as well asoptimization of water treatment systems.With low detection limits and greatly extended detectionrange, the TD-120 provides the necessary tools andease ofuse to meet todays complex oil in water needsUV FluorescenceLow ppb 6000 ppm (dependent on oil Solubility in water)32-122F(0-50C) Configurable early, high system, Cell condition, High Temperature4-20mA isolated, selectable loop or instrument powered Optional: HART UV FluorescenceLow ppb 6000 ppm (dependent on oil Solubility in water)32-122F(0-50C) Configurable early, high system, Cell condition, High Temperature4-20mA isolated, selectable loop or instrument powered Optional: HART
Oil in Water Monitor For Hydrocarbons
Looking to purchase in bulk?
  • Purchase item in bulk quantity
  • Get best price for your business

Comments (0)

No customer reviews for the moment.

Frequently Asked Questions

The detection range is from low parts per billion (ppb) to 6000 parts per million (ppm), depending on the solubility of the oil in water.

It can detect various hydrocarbons including diesel, fuel oil, crude oil, gasoline, jet fuel, lubricating oils, phenol, heat transfer fluids, and aromatic chemicals.

The operating temperature range is between 32°F to 122°F (0°C to 50°C).

It requires a power supply of 100-240 VAC at 50/60 Hz, with a maximum current of 1.3 A for a single phase.

It uses ultraviolet fluorescence as its measurement principle, which allows it to detect hydrocarbons effectively even in challenging conditions.

It is suitable for applications such as steam condensate, boiler feed water, cooling water, intake protection, dam sumps, and process optimization.

Yes, it is configurable for early and high system alerts, cell condition monitoring, and high-temperature applications.

It provides a 4-20 mA isolated output, with options for selectable loop or instrument powering, and can include HART communication.

Installation requirements include ensuring proper power supply and configuring the unit according to site conditions and application needs.

The care packages include calibration to known standards or calibration to target hydrocarbons using sample analysis, tailored to site conditions.

Yes, it is designed to be resistant to influences from dirty or turbid water that typically affect UV absorption or light scatter measurements.

Related Products

$63.45
$1.27 Save 98%
Tax included
Quantity
Delivery Time Delivered within 0-3 days
  • Global Payments 140+ CountriesGlobal Payments 140+ Countries
  • Global Shipping Fedex/UPS/DHL/Aramex/
BlueDart/Delhivery/DP WorldGlobal Shipping Fedex/UPS/DHL/Aramex/ BlueDart/Delhivery/DP World
  • 24/7 Customer Support Email/Chat/Telephonic Support24/7 Customer Support Email/Chat/Telephonic Support
$63.45
$1.27
Tax included