Burkert 8041 Series Insertion Flow Controller with Frequency, Relay, Analogue Output, 400 mm Pipe Diameter, 36V dc 552779

Category Flow Controller Brand Bürkert Condition New

Specifications

Country of Origin France
Accuracy +/- 2% of measured value from 1 - 10m/s (Teach-In)
Measuring range 0.2 - 10m/s
Brand Burkert
Material PPA housing, stainless steel insertion finger and electrodes (316L/1.4404),PEEK (FDA quality) electrode holder, FKM seals (FDA quality)
Output signal 4-20mA, programmable pulse output, relays to 250V/3A (N/O or N/C according to application need)
Model 552779
Mount Type Insertion
Ingress Protection IP65 cable glands
Series 8041
Maximum Operating Temperature 60°C
Fluid temperature -20°C to 150°C
Display Screen 10-LED Bargraph
Minimum Operating Temperature -10°C
Control Output Frequency, Relay, Analogue
Fluid pressure up to PN16, depending on type of installation flow adaptor used
Terminal type Cable Gland
Maximum Supply Voltage 36V dc
Maximum Pipe Diameter 400mm

Key Features

  • Equipped with frequency, relay, and analogue control outputs for versatile applications.
  • 10-LED bargraph display screen provides clear visual status indication.
  • Insertion mounting type designed for easy installation in large diameter pipes.
  • Operates within temperature range from -10°C minimum to 60°C maximum supply voltage at 36V dc.
  • Fluid temperature tolerance from -20°C to 150°C supports high temperature applications.
  • Accuracy of ±2% within measuring range of 0.2 to 10 m/s ensures reliable performance.
  • Constructed with PPA housing, stainless steel 316L insertion finger and electrodes, PEEK FDA-grade electrode holder, and FKM FDA-grade seals.
  • Ingress protection rating of IP65 with cable glands for robust industrial environments.

Product Description

Burkert 552779 Insertion Flow Controller 8041 Series precisely measures liquid flow with robust construction and versatile outputs. Designed specifically for pipes up to 400 mm in diameter, this device is suitable for demanding industrial applications including Clean-In-Place (CIP) systems, industrial washing machines, and heating or cooling systems.

The controller supports multiple output types including frequency, relay contacts, and analogue signals to interface easily with control and monitoring systems. The built-in 10-LED bargraph display allows for quick, at-a-glance flow status observation.

Featuring a high-grade PPA housing combined with stainless steel insertion fingers and electrodes made of 316L (1.4404), it offers excellent chemical resistance and durability. The electrode holder is made of FDA-approved PEEK, while the seals feature FDA-grade FKM, ensuring compliance for food and pharmaceutical industry processes.

The device operates on a supply voltage range from 18 to 36V dc, with a maximum operating temperature of 60°C for the unit’s electronics and fluid temperature tolerance up to 150°C. Its insertion mounting design facilitates installation without pipe modification. Accuracy is ±2% within a measuring range of 0.2 to 10 m/s, adaptable via Teach-In.

Ingress protection is rated at IP65, with cable gland terminals designed to withstand industrial environments. The unit can handle fluid pressures up to PN16, depending on the installation adaptor used.

Frequency, relay, and analogue control output options for flexible system integration. Suitable for high temperature liquid flow measurement in industrial processes. FDA-compliant materials support applications in food and pharmaceutical industries.

Durable stainless steel and PPA construction ensure longevity. Simple insertion mounting minimizes installation disruption. Accurate flow measurement with ±2% accuracy and broad velocity range. Ingress protection of IP65 for reliable operation in harsh environments.

Manufactured in France under rigid quality standards. Use cases include CIP systems, heating and cooling installations, and industrial washing machines. Explore more Flow Controllers and sensors by Burkert and related automation control gear at EnvMart for your industrial and laboratory requirements.

Burkert 8041 Series Insertion Flow Controller with Frequency, Relay, Analogue Output, 400 mm Pipe Diameter, 36V dc 552779
Looking to purchase in bulk?
  • Purchase item in bulk quantity
  • Get best price for your business

Comments (0)

No customer reviews for the moment.

Frequently Asked Questions

The measuring range of this model is from 0.2 to 10 m/s.

It provides frequency, relay contacts, and analogue outputs, including a programmable pulse output and relays rated up to 250V/3A.

The accuracy is ±2% of the measured value within the range of 1 to 10 m/s.

This unit is designed for insertion in pipes with a maximum diameter of 400 mm.

The maximum operating temperature for the electronics is 60°C.

It features a PPA housing, stainless steel 316L insertion finger and electrodes, a PEEK FDA-grade electrode holder, and FKM FDA-grade seals.

The fluid temperature tolerance ranges from -20°C to 150°C.

This model uses an insertion mounting type, allowing for easy installation without pipe modification.

The ingress protection rating is IP65, which provides protection against dust and water ingress.

The minimum operating temperature is -10°C.

It is suitable for applications such as Clean-In-Place (CIP) systems, industrial washing machines, and heating or cooling systems.

The supply voltage range is from 18 to 36V dc.

Related Products

Other Products from this brand

$1,785.70
$1,732.13 Save 3%
Tax included
Quantity
Delivery Time Delivered within 0-3 days
  • Global Payments 140+ CountriesGlobal Payments 140+ Countries
  • Global Shipping Fedex/UPS/DHL/Aramex/
BlueDart/Delhivery/DP WorldGlobal Shipping Fedex/UPS/DHL/Aramex/ BlueDart/Delhivery/DP World
  • 24/7 Customer Support Email/Chat/Telephonic Support24/7 Customer Support Email/Chat/Telephonic Support
$1,785.70
$1,732.13
Tax included