Labtron LICS-A22 Ion Chromatograph System
World's First Climate Tech Platform | Free Delivery in India | Global Shipping

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase
| Brand | Labtron |
|---|---|
| Power Supply | DC 220 V / 60 Hz DC 24V |
| Power | 150 W |
| Net Weight | 48 kg |
| Sampling mode | Full quantitative loop sampling |
| Pipe Material | Plastic |
| Model | LICS-A22 |
| Gross Weight | 73 kg |
| Control System | ARM STM32 series of 32 bit embedded |
| Maximum Pressure | 20 MPa 35 MPa (PEEK) |
| Control Mode | By Stepper motor |
| Flow range | 0.001 to 9.999 ml/min |
| External Dimension | 500 × 500 × 760 mm |
| Pressure Display Accuracy | ≤ 0.1 MPa |
| Dimension (L×W×H) | 400 × 540 × 260 mm |
| Communication Mode | RS232 |
| Flow Stability | (0.2 to 0.5) ml/min ≤ 3% / (0.5 to 1.0) ml/min ≤ 2% / Greater than 1.0 ml/min ≤ 2% |
| Quantitative Repeatability | ≤ 1.0 % |
| Pressure Pulse | ≤ 0.5% |
| Eluent Concentration Range | 0.1 to 100 mM |
| Minimum Pressure | 5 MPa |
| Degassing Efficiency | 10 ml/min 90% |
| Detection Mode (Conductivity Detector) | Bipolar conductivity detection |
| Cell Volume (Conductivity Detector) | ≤ 0.8 μL |
| Detection Range (Conductivity Detector) | 0 to 45000 μS/cm |
| Output Voltage (Conductivity Detector) | -6000 to +6000 mV (adjustable) |
| Controlling Temperature Accuracy (Conductivity Detector) | ± 0.01°C |
| Maximum Pressure (Conductivity Detector) | 10 MPa |
| Linear Range (Conductivity Detector) | ≥ 103 |
| Instruments Linearity (Conductivity Detector) | ≥ 0.999 |
| Plastic Flow Path (Flow System) | Made up of PEEK Material |
| Six Way Valve (Flow System) | PEEK Material pressure 5000 psi / independent automatic collection and flow function |
| Ion Chromatographic Pump Type | High pressure and low pulse double plunger tandem advection pump |
| Numerical Control and Electromagnetic Injection Maximum Pressure | 35 MPa |
| Contact Material of Rotor | PEEK |
| Column Heater Operating Temperature Range | Room temperature 20°C to 60°C (68 to 140°F) |
| Column Heater Controlling Temperature Accuracy | ± 0.01°C |
| Column Heater Allowable Deviation of Column Heater Temp | ± 2°C |
| Column Heater Temperature Stability | ≤ 1°C/h |
| Thermal Buffer for Eluent Temperature Range | 25 to 40°C (77 to 104°F) |
| Type (Degassing Device) | Built-in Low Pressure |
| Vacuum Degree (Degassing Device) | (-) 70 kPa |
| Max Flow Rate (Degassing Device) | 10 ml/min |
| Internal Volume (Degassing Device) | 30 μL |
| Type (Conductivity Detector) | Temperature Control and Bipolar Conductivity Detector |
| Operating Temperature (Conductivity Detector) | Room Temperature 5 to 60°C ( 41 to 140°F) |
| Qualitative Repeatability | ≤ 1.0 % |
| Eluent Type | KOH/NaOH |
| Concentration Increment | 0.1 mM |
| Flow Rate Change | 0.1 to 3.0 ml/min |
| Auto Sampler Display | 7 inch touch control / color LCD display |
| Injection mode | X-Y-Z three axis operational mode |
| Number of injection units | 2 ml × 120 units |
| Repeat injection | 1 to 5 times (optional) |
| Injection Volume | 25 to 500 µl |
| Sample syringe Capacity | 5 ml maximum |
| Circulation time | ≤ 6 minutes |
| Injection accuracy | ≤ 0.5 % |
| Residual sample | ≤ 0.05 % |
| Embedded | LQFP100 |
Ion chromatograph system LICS-A22 with cation and anion dual channel design, independently operates and simultaneously detects both channels without disturbing each other. The temperature-controlled bipolar conductivity detector improves the detection performance and stability of the instrument. The system is comprised of an auto sampler, anion, and cation suppressor.
Applications:
Used to detect small molecules (in the form of anion, cation) in water testing & processing plants, food, chemical and dye industry, mining, metallurgy, and other fields.
Optional Accessories:
Review sent
Your review cannot be sent

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase
| Brand | Labtron |
|---|---|
| Power Supply | DC 220 V / 60 Hz DC 24V |
| Power | 150 W |
| Net Weight | 48 kg |
| Sampling mode | Full quantitative loop sampling |
| Pipe Material | Plastic |
| Model | LICS-A22 |
| Gross Weight | 73 kg |
| Control System | ARM STM32 series of 32 bit embedded |
| Maximum Pressure | 20 MPa 35 MPa (PEEK) |
| Control Mode | By Stepper motor |
| Flow range | 0.001 to 9.999 ml/min |
| External Dimension | 500 × 500 × 760 mm |
| Pressure Display Accuracy | ≤ 0.1 MPa |
| Dimension (L×W×H) | 400 × 540 × 260 mm |
| Communication Mode | RS232 |
| Flow Stability | (0.2 to 0.5) ml/min ≤ 3% / (0.5 to 1.0) ml/min ≤ 2% / Greater than 1.0 ml/min ≤ 2% |
| Quantitative Repeatability | ≤ 1.0 % |
| Pressure Pulse | ≤ 0.5% |
| Eluent Concentration Range | 0.1 to 100 mM |
| Minimum Pressure | 5 MPa |
| Degassing Efficiency | 10 ml/min 90% |
| Detection Mode (Conductivity Detector) | Bipolar conductivity detection |
| Cell Volume (Conductivity Detector) | ≤ 0.8 μL |
| Detection Range (Conductivity Detector) | 0 to 45000 μS/cm |
| Output Voltage (Conductivity Detector) | -6000 to +6000 mV (adjustable) |
| Controlling Temperature Accuracy (Conductivity Detector) | ± 0.01°C |
| Maximum Pressure (Conductivity Detector) | 10 MPa |
| Linear Range (Conductivity Detector) | ≥ 103 |
| Instruments Linearity (Conductivity Detector) | ≥ 0.999 |
| Plastic Flow Path (Flow System) | Made up of PEEK Material |
| Six Way Valve (Flow System) | PEEK Material pressure 5000 psi / independent automatic collection and flow function |
| Ion Chromatographic Pump Type | High pressure and low pulse double plunger tandem advection pump |
| Numerical Control and Electromagnetic Injection Maximum Pressure | 35 MPa |
| Contact Material of Rotor | PEEK |
| Column Heater Operating Temperature Range | Room temperature 20°C to 60°C (68 to 140°F) |
| Column Heater Controlling Temperature Accuracy | ± 0.01°C |
| Column Heater Allowable Deviation of Column Heater Temp | ± 2°C |
| Column Heater Temperature Stability | ≤ 1°C/h |
| Thermal Buffer for Eluent Temperature Range | 25 to 40°C (77 to 104°F) |
| Type (Degassing Device) | Built-in Low Pressure |
| Vacuum Degree (Degassing Device) | (-) 70 kPa |
| Max Flow Rate (Degassing Device) | 10 ml/min |
| Internal Volume (Degassing Device) | 30 μL |
| Type (Conductivity Detector) | Temperature Control and Bipolar Conductivity Detector |
| Operating Temperature (Conductivity Detector) | Room Temperature 5 to 60°C ( 41 to 140°F) |
| Qualitative Repeatability | ≤ 1.0 % |
| Eluent Type | KOH/NaOH |
| Concentration Increment | 0.1 mM |
| Flow Rate Change | 0.1 to 3.0 ml/min |
| Auto Sampler Display | 7 inch touch control / color LCD display |
| Injection mode | X-Y-Z three axis operational mode |
| Number of injection units | 2 ml × 120 units |
| Repeat injection | 1 to 5 times (optional) |
| Injection Volume | 25 to 500 µl |
| Sample syringe Capacity | 5 ml maximum |
| Circulation time | ≤ 6 minutes |
| Injection accuracy | ≤ 0.5 % |
| Residual sample | ≤ 0.05 % |
| Embedded | LQFP100 |
Ion chromatograph system LICS-A22 with cation and anion dual channel design, independently operates and simultaneously detects both channels without disturbing each other. The temperature-controlled bipolar conductivity detector improves the detection performance and stability of the instrument. The system is comprised of an auto sampler, anion, and cation suppressor.
Applications:
Used to detect small molecules (in the form of anion, cation) in water testing & processing plants, food, chemical and dye industry, mining, metallurgy, and other fields.