Previous
Next
Share
Free Delivery in India | Lowest Global Shipping Charges
24/7 Customer Support
24/7 Customer Support

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

24/7 Customer Support
Save up to 28% with GST Input

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

Lowest Price Challenge
# Lowest Price Challenge

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Lowest Price Challenge
100% Original Products

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase

Labtron LICS-A20 Ion Chromatograph System

SKU ADBUS Category Ion Chromatography Brand Labtron

Specifications

Brand Labtron
Net Weight 26 kg
Model LICS-A20
Gross Weight 32 Kg
Temperature Stability ≤ 0.05℃/h
Pump Type High-pressure and low-pulse two-piston tandem advection pump
Maximum Pressure 30MPa
Pump Flow Rate 0.001 to 9.999mL/min
Alarm system Pressure Alarm / Liquid Leakage Alarm / and Washing Liquid Alarm
External Dimension (W × L × H) 360 × 500 × 560 mm
Detector Temperature range Ambient +5℃ to 60℃
Pump Flow Accuracy ≤ 0.1%
Pump Flow Precision ≤ 0.1%
Pump Maximum Pressure 42MPa
Detector Baseline Noise ≤ 0.0002μS/cm
Detector Baseline Drift ≤ 0.001μS
Eluent Concentration Range 0.1 to 100mM
Eluent Concentration Increment 0.1mM
Eluent Flow Rate 0.1 to 5.0mL/min
Minimum Pressure 5MPa
Accuracy Of Gradient 0.0015
Vacuum Degasser Degree -70kPa
Degasser Internal Volume 300μL
Degasser Max Flow Rate 10mL/min
Degassing Efficiency 1.0mL/min 90%
Degassing Volume 7.5mL
Flow Path Chemically inert / metal-free PEEK flow paths
Pump Pressure Ripple ≤ 0.5%
External Diameter of The Tube 1/16"
Valve Control Mode Stepper Motor
Valve Power Supply 24V (DC)
Column Heater Temperature Range Ambient + 5 to 60 ℃
Column Heater Temperature Accuracy ±0.1℃
Columns Supported 2 / 3 / 4 / and 5 mm I.D.
Analytical Column Size 250 mm
Guard Column Size 50 mm
Conductivity Detector Type Auto-range conductivity
Conductivity Detector Cell Volume ≤ 0.8μL
Conductivity Detection Range 0 to 50000μS/cm
Conductivity Detector Resolution ≤ 0.0020nS/cm
Detector Output Voltage (V) -6000 to +6000mv(adjustable)
Detector Electronic Noise 0.02nS
Detector Temperature Accuracy ±0.01℃
Detector Temperature Compensation 1.7 %/℃
Detector Maximum Pressure 10.0MPa
Detector Instrument Linearity ≥ 0.999
Detector Quantitative Repeatability ≤ 0.2%
Detector Qualitative Repeatability ≤ 0.5%
Minimum Detectability Concentration Clˉ ≤ 0.0001ug/mL / Li⁺ ≤ 0.0001ug/mL
Suppressor Type Self-Regeneration electrolytic micromembrane suppressor
Suppressor Maximum Pressure 6.0MPa
Non-Suppressed Chromatography Yes/support
Suppressor Void Volume Less than40μL (4mm) / Less than15μL (2mm)
Suppressor Power Supply 150W
Generator Eluent Types KOH/NaOH/LiOH/MSA

Key Features

  • Various alarms for protection against operational issues
  • Auto-range conductivity detector expands signal range
  • Gas-liquid separator for removing bubble impact
  • High-performance auto-sampler enhances injection control
  • Start-up and warm-up procedures can be pre-set
  • Vacuum degasser for testing stability
  • Real-time monitoring ensures timely consumable replacement

Product Description

Ion chromatograph system LICS-A20 offers a pump flow rate of 0.001 to 9.999 mL/min with an eluent flow rate of 0.1 to 5.0 mL/min. It features a built-in eluent generator for equal or gradient elution. Capable of performing suppression or non-suppression conductivity detection. The software features a baseline deduction function and filtering algorithm to effectively eliminate baseline drift. Our system is intelligent, stable, and accurate in performance.

Applications:

Our ion chromatograph system can be used to detect fluoride and chloride in coal tar, ammonium in photoresists, bromate and bromide in drinking water, anions in engine coolants, lithium battery electrolytes, etc.

Standard Accessories:

  • 1 Ion chromatograph host
  • 1 High-pressure double plunger advection pump
  • 1 Conductivity detector
  • 1 Anion column
  • 1 Anion guard column
  • 1 Anion suppressor
  • 1 Cation column
  • 1 Cation guard column
  • 1 Cation suppressor
  • 1 Chromatography software
  • 1 Column heater
  • 1 PEEK flow path
  • 1 Online gas-liquid separator
  • 1 Spare parts kits
  • 1 Vacuum degassing pump
  • 1 Sand core filtration device
  • 100 0.22um syringe filters
  • 1 Built-in anion eluent generator
  • 1 Autosampler
  • 1 Leakage sensor
  • 1 Gas-liquid separator.

Comments (0)

Related Products

$69.50
Tax included
Quantity
Delivery Time Delivered within 0-3 days
  • Genuine Products   
  • Global Shipping 
  • Secured Payments
Previous
Next
Share
Free Delivery in India | Lowest Global Shipping Charges
24/7 Customer Support
24/7 Customer Support

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

24/7 Customer Support
Save up to 28% with GST Input

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

Lowest Price Challenge
# Lowest Price Challenge

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Lowest Price Challenge
100% Original Products

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase

Labtron LICS-A20 Ion Chromatograph System

SKU ADBUS Category Ion Chromatography Brand Labtron

Specifications

Brand Labtron
Net Weight 26 kg
Model LICS-A20
Gross Weight 32 Kg
Temperature Stability ≤ 0.05℃/h
Pump Type High-pressure and low-pulse two-piston tandem advection pump
Maximum Pressure 30MPa
Pump Flow Rate 0.001 to 9.999mL/min
Alarm system Pressure Alarm / Liquid Leakage Alarm / and Washing Liquid Alarm
External Dimension (W × L × H) 360 × 500 × 560 mm
Detector Temperature range Ambient +5℃ to 60℃
Pump Flow Accuracy ≤ 0.1%
Pump Flow Precision ≤ 0.1%
Pump Maximum Pressure 42MPa
Detector Baseline Noise ≤ 0.0002μS/cm
Detector Baseline Drift ≤ 0.001μS
Eluent Concentration Range 0.1 to 100mM
Eluent Concentration Increment 0.1mM
Eluent Flow Rate 0.1 to 5.0mL/min
Minimum Pressure 5MPa
Accuracy Of Gradient 0.0015
Vacuum Degasser Degree -70kPa
Degasser Internal Volume 300μL
Degasser Max Flow Rate 10mL/min
Degassing Efficiency 1.0mL/min 90%
Degassing Volume 7.5mL
Flow Path Chemically inert / metal-free PEEK flow paths
Pump Pressure Ripple ≤ 0.5%
External Diameter of The Tube 1/16"
Valve Control Mode Stepper Motor
Valve Power Supply 24V (DC)
Column Heater Temperature Range Ambient + 5 to 60 ℃
Column Heater Temperature Accuracy ±0.1℃
Columns Supported 2 / 3 / 4 / and 5 mm I.D.
Analytical Column Size 250 mm
Guard Column Size 50 mm
Conductivity Detector Type Auto-range conductivity
Conductivity Detector Cell Volume ≤ 0.8μL
Conductivity Detection Range 0 to 50000μS/cm
Conductivity Detector Resolution ≤ 0.0020nS/cm
Detector Output Voltage (V) -6000 to +6000mv(adjustable)
Detector Electronic Noise 0.02nS
Detector Temperature Accuracy ±0.01℃
Detector Temperature Compensation 1.7 %/℃
Detector Maximum Pressure 10.0MPa
Detector Instrument Linearity ≥ 0.999
Detector Quantitative Repeatability ≤ 0.2%
Detector Qualitative Repeatability ≤ 0.5%
Minimum Detectability Concentration Clˉ ≤ 0.0001ug/mL / Li⁺ ≤ 0.0001ug/mL
Suppressor Type Self-Regeneration electrolytic micromembrane suppressor
Suppressor Maximum Pressure 6.0MPa
Non-Suppressed Chromatography Yes/support
Suppressor Void Volume Less than40μL (4mm) / Less than15μL (2mm)
Suppressor Power Supply 150W
Generator Eluent Types KOH/NaOH/LiOH/MSA

Key Features

  • Various alarms for protection against operational issues
  • Auto-range conductivity detector expands signal range
  • Gas-liquid separator for removing bubble impact
  • High-performance auto-sampler enhances injection control
  • Start-up and warm-up procedures can be pre-set
  • Vacuum degasser for testing stability
  • Real-time monitoring ensures timely consumable replacement

Product Description

Ion chromatograph system LICS-A20 offers a pump flow rate of 0.001 to 9.999 mL/min with an eluent flow rate of 0.1 to 5.0 mL/min. It features a built-in eluent generator for equal or gradient elution. Capable of performing suppression or non-suppression conductivity detection. The software features a baseline deduction function and filtering algorithm to effectively eliminate baseline drift. Our system is intelligent, stable, and accurate in performance.

Applications:

Our ion chromatograph system can be used to detect fluoride and chloride in coal tar, ammonium in photoresists, bromate and bromide in drinking water, anions in engine coolants, lithium battery electrolytes, etc.

Standard Accessories:

  • 1 Ion chromatograph host
  • 1 High-pressure double plunger advection pump
  • 1 Conductivity detector
  • 1 Anion column
  • 1 Anion guard column
  • 1 Anion suppressor
  • 1 Cation column
  • 1 Cation guard column
  • 1 Cation suppressor
  • 1 Chromatography software
  • 1 Column heater
  • 1 PEEK flow path
  • 1 Online gas-liquid separator
  • 1 Spare parts kits
  • 1 Vacuum degassing pump
  • 1 Sand core filtration device
  • 100 0.22um syringe filters
  • 1 Built-in anion eluent generator
  • 1 Autosampler
  • 1 Leakage sensor
  • 1 Gas-liquid separator.

Comments (0)

$69.50
Tax included
Quantity
Delivery Time Delivered within 0-3 days
  • Genuine Products   
  • Global Shipping 
  • Secured Payments
$69.50
Tax included