| Brand | Labtron |
|---|---|
| Net Weight | 26 kg |
| Model | LICS-A20 |
| Gross Weight | 32 Kg |
| Temperature Stability | ≤ 0.05℃/h |
| Pump Type | High-pressure and low-pulse two-piston tandem advection pump |
| Maximum Pressure | 30MPa |
| Pump Flow Rate | 0.001 to 9.999mL/min |
| Alarm system | Pressure Alarm / Liquid Leakage Alarm / and Washing Liquid Alarm |
| External Dimension (W × L × H) | 360 × 500 × 560 mm |
| Detector Temperature range | Ambient +5℃ to 60℃ |
| Pump Flow Accuracy | ≤ 0.1% |
| Pump Flow Precision | ≤ 0.1% |
| Pump Maximum Pressure | 42MPa |
| Detector Baseline Noise | ≤ 0.0002μS/cm |
| Detector Baseline Drift | ≤ 0.001μS |
| Eluent Concentration Range | 0.1 to 100mM |
| Eluent Concentration Increment | 0.1mM |
| Eluent Flow Rate | 0.1 to 5.0mL/min |
| Minimum Pressure | 5MPa |
| Accuracy Of Gradient | 0.0015 |
| Vacuum Degasser Degree | -70kPa |
| Degasser Internal Volume | 300μL |
| Degasser Max Flow Rate | 10mL/min |
| Degassing Efficiency | 1.0mL/min 90% |
| Degassing Volume | 7.5mL |
| Flow Path | Chemically inert / metal-free PEEK flow paths |
| Pump Pressure Ripple | ≤ 0.5% |
| External Diameter of The Tube | 1/16" |
| Valve Control Mode | Stepper Motor |
| Valve Power Supply | 24V (DC) |
| Column Heater Temperature Range | Ambient + 5 to 60 ℃ |
| Column Heater Temperature Accuracy | ±0.1℃ |
| Columns Supported | 2 / 3 / 4 / and 5 mm I.D. |
| Analytical Column Size | 250 mm |
| Guard Column Size | 50 mm |
| Conductivity Detector Type | Auto-range conductivity |
| Conductivity Detector Cell Volume | ≤ 0.8μL |
| Conductivity Detection Range | 0 to 50000μS/cm |
| Conductivity Detector Resolution | ≤ 0.0020nS/cm |
| Detector Output Voltage (V) | -6000 to +6000mv(adjustable) |
| Detector Electronic Noise | 0.02nS |
| Detector Temperature Accuracy | ±0.01℃ |
| Detector Temperature Compensation | 1.7 %/℃ |
| Detector Maximum Pressure | 10.0MPa |
| Detector Instrument Linearity | ≥ 0.999 |
| Detector Quantitative Repeatability | ≤ 0.2% |
| Detector Qualitative Repeatability | ≤ 0.5% |
| Minimum Detectability Concentration | Clˉ ≤ 0.0001ug/mL / Li⁺ ≤ 0.0001ug/mL |
| Suppressor Type | Self-Regeneration electrolytic micromembrane suppressor |
| Suppressor Maximum Pressure | 6.0MPa |
| Non-Suppressed Chromatography | Yes/support |
| Suppressor Void Volume | Less than40μL (4mm) / Less than15μL (2mm) |
| Suppressor Power Supply | 150W |
| Generator Eluent Types | KOH/NaOH/LiOH/MSA |
Ion chromatograph system LICS-A20 offers a pump flow rate of 0.001 to 9.999 mL/min with an eluent flow rate of 0.1 to 5.0 mL/min. It features a built-in eluent generator for equal or gradient elution. Capable of performing suppression or non-suppression conductivity detection. The software features a baseline deduction function and filtering algorithm to effectively eliminate baseline drift. Our system is intelligent, stable, and accurate in performance.
Applications:
Our ion chromatograph system can be used to detect fluoride and chloride in coal tar, ammonium in photoresists, bromate and bromide in drinking water, anions in engine coolants, lithium battery electrolytes, etc.
Standard Accessories:
Review sent
Your review cannot be sent

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase
| Brand | Labtron |
|---|---|
| Net Weight | 26 kg |
| Model | LICS-A20 |
| Gross Weight | 32 Kg |
| Temperature Stability | ≤ 0.05℃/h |
| Pump Type | High-pressure and low-pulse two-piston tandem advection pump |
| Maximum Pressure | 30MPa |
| Pump Flow Rate | 0.001 to 9.999mL/min |
| Alarm system | Pressure Alarm / Liquid Leakage Alarm / and Washing Liquid Alarm |
| External Dimension (W × L × H) | 360 × 500 × 560 mm |
| Detector Temperature range | Ambient +5℃ to 60℃ |
| Pump Flow Accuracy | ≤ 0.1% |
| Pump Flow Precision | ≤ 0.1% |
| Pump Maximum Pressure | 42MPa |
| Detector Baseline Noise | ≤ 0.0002μS/cm |
| Detector Baseline Drift | ≤ 0.001μS |
| Eluent Concentration Range | 0.1 to 100mM |
| Eluent Concentration Increment | 0.1mM |
| Eluent Flow Rate | 0.1 to 5.0mL/min |
| Minimum Pressure | 5MPa |
| Accuracy Of Gradient | 0.0015 |
| Vacuum Degasser Degree | -70kPa |
| Degasser Internal Volume | 300μL |
| Degasser Max Flow Rate | 10mL/min |
| Degassing Efficiency | 1.0mL/min 90% |
| Degassing Volume | 7.5mL |
| Flow Path | Chemically inert / metal-free PEEK flow paths |
| Pump Pressure Ripple | ≤ 0.5% |
| External Diameter of The Tube | 1/16" |
| Valve Control Mode | Stepper Motor |
| Valve Power Supply | 24V (DC) |
| Column Heater Temperature Range | Ambient + 5 to 60 ℃ |
| Column Heater Temperature Accuracy | ±0.1℃ |
| Columns Supported | 2 / 3 / 4 / and 5 mm I.D. |
| Analytical Column Size | 250 mm |
| Guard Column Size | 50 mm |
| Conductivity Detector Type | Auto-range conductivity |
| Conductivity Detector Cell Volume | ≤ 0.8μL |
| Conductivity Detection Range | 0 to 50000μS/cm |
| Conductivity Detector Resolution | ≤ 0.0020nS/cm |
| Detector Output Voltage (V) | -6000 to +6000mv(adjustable) |
| Detector Electronic Noise | 0.02nS |
| Detector Temperature Accuracy | ±0.01℃ |
| Detector Temperature Compensation | 1.7 %/℃ |
| Detector Maximum Pressure | 10.0MPa |
| Detector Instrument Linearity | ≥ 0.999 |
| Detector Quantitative Repeatability | ≤ 0.2% |
| Detector Qualitative Repeatability | ≤ 0.5% |
| Minimum Detectability Concentration | Clˉ ≤ 0.0001ug/mL / Li⁺ ≤ 0.0001ug/mL |
| Suppressor Type | Self-Regeneration electrolytic micromembrane suppressor |
| Suppressor Maximum Pressure | 6.0MPa |
| Non-Suppressed Chromatography | Yes/support |
| Suppressor Void Volume | Less than40μL (4mm) / Less than15μL (2mm) |
| Suppressor Power Supply | 150W |
| Generator Eluent Types | KOH/NaOH/LiOH/MSA |
Ion chromatograph system LICS-A20 offers a pump flow rate of 0.001 to 9.999 mL/min with an eluent flow rate of 0.1 to 5.0 mL/min. It features a built-in eluent generator for equal or gradient elution. Capable of performing suppression or non-suppression conductivity detection. The software features a baseline deduction function and filtering algorithm to effectively eliminate baseline drift. Our system is intelligent, stable, and accurate in performance.
Applications:
Our ion chromatograph system can be used to detect fluoride and chloride in coal tar, ammonium in photoresists, bromate and bromide in drinking water, anions in engine coolants, lithium battery electrolytes, etc.
Standard Accessories:
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Review sent
Your review cannot be sent
Labtron LICS-A20 Ion Chromatograph System
Comments (0)
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent