PR Electronics 3100 Series Isolating Signal Converter Current Input Current Output 0 - 20.5 mA 16.8, 31.2 V dc Supply ATEX 3103

Category Signal Conditioner Brand PR Electronics Condition New

Specifications

Country of Origin Denmark
Brand PR Electronics
Model 3103
IP Rating IP20
Mount Type DIN Rail
Series 3100
Maximum Operating Temperature 70°C
Minimum Operating Temperature -25°C
Terminal type Screw
Output Range 0 → 20.5 mA
Input Range 0 → 20.5 mA
Supply Voltage 16.8, 31.2V dc
Hazardous Area Certification ATEX
Input Signal Type Current
Standards/Approvals EAC, RoHS, UL
PR 3103 isolated signal repeater for the isolation and 1 1 conversion of standard current signals. Designed for galvanic isolation of current signals to SCADA systems or PLC equipment

Key Features

  • Offers high basic accuracy of 0.05% across signal ranges.
  • Operates on supply voltages of 16.8 V dc and 31.2 V dc.
  • Designed for DIN rail mounting with screw terminal connections.
  • Functions effectively in temperature ranges from -25°C to 70°C.
  • Features 2.5 kVAC isolation for excellent noise immunity and prevention of ground loops.
  • Includes LED status indicators for device health and error signaling.
  • Supports DIP-switch programming with pre-calibrated input/output ranges.
  • Complies with EAC, RoHS, UL standards for industrial applications.

Product Description

PR Electronics 3103 Isolated Signal Repeater is part of the 3100 Series designed for precise isolation and 1:1 conversion of standard current signals. It excels at providing galvanic isolation of current signals to SCADA systems or PLC equipment, ensuring signal integrity and protection against interference. This device operates with a supply voltage of 16.8 V dc and 31.2 V dc, supporting input and output current ranges of 0 to 20.5 mA.

The 3100 Series devices are compact Signal Conditioners with a slim 6 mm housing, offering exceptional performance and electromagnetic compatibility (EMC) immunity suitable for indoor and outdoor industrial environments. They are designed to withstand wide ambient temperature variations from -25°C to +70°C, making them ideal for locations with fluctuating conditions.

Equipped with advanced microprocessor technology, the PR 3103 ensures high base accuracy of 0.05% throughout available signal ranges. It features a low temperature coefficient of less than 0.01% per °C and long-term accuracy better than 0.1% over three years without requiring recalibration. Installation is straightforward via DIN rail mounting with screw terminals, allowing both vertical and horizontal orientation without air gap separation.

Its galvanic isolation rating of 2.5 kVAC provides robust noise immunity and effectively prevents ground loops, enhancing measurement reliability. The device is protected against over-voltage and incorrect polarity wiring, ensuring safe and error-free installation. A front LED indicator displays device status and alerts to setup or hardware errors.

Programmed using DIP switches, the 3103 model offers pre-calibrated input/output ranges that can be changed by simply toggling switches and power cycling - eliminating the need for manual recalibration. Select versions also enable HART programming for enhanced configurability.

High precision isolation and conversion of current signals. Exceptional electromagnetic noise immunity and protection. Wide operating temperature range for versatile industrial use. Easy and error-proof installation with DIN rail and screw terminals.

Certified for use in ATEX Ex zone 2 and IECEx Zone 2 hazardous locations. Robust build quality with compliance to EAC, RoHS, and UL standards. Low power consumption with microprocessor efficiency. Suitable for automation, control, monitoring, and signal conditioning applications in electrical, industrial, and manufacturing environments.

PR Electronics 3103 offers a reliable solution for galvanic isolation and signal conditioning in SCADA and PLC-based systems, enhancing process measurement accuracy and industrial automation safety. It fits applications spanning electrical automation, instrumentation, process control, and hazardous area signal transmission.

Explore more from the PR Electronics 3100 Series isolating signal converters at EnvMart to optimize your electrical and automation projects with industry-grade precision and safety.

PR Electronics 3100 Series Isolating Signal Converter Current Input Current Output 0 - 20.5 mA 16.8, 31.2 V dc Supply ATEX 3103
Looking to purchase in bulk?
  • Purchase item in bulk quantity
  • Get best price for your business

Comments (0)

No customer reviews for the moment.

Frequently Asked Questions

The PR Electronics 3103 supports an input and output current range of 0 to 20.5 mA.

This unit operates on supply voltages of 16.8 V dc and 31.2 V dc.

The maximum operating temperature for the 3103 is 70°C.

It is designed for DIN rail mounting with screw terminal connections, allowing for both vertical and horizontal orientation.

The PR Electronics 3103 is certified for use in ATEX Ex zone 2 and IECEx Zone 2 hazardous locations.

This model features a galvanic isolation rating of 2.5 kVAC, providing excellent noise immunity and preventing ground loops.

The device complies with EAC, RoHS, and UL standards for industrial applications.

It is designed for the isolation and 1:1 conversion of standard current signals to SCADA systems or PLC equipment.

The 3103 can be programmed using DIP switches, allowing for pre-calibrated input/output ranges to be changed easily without manual recalibration.

The minimum operating temperature for the 3103 is -25°C.

The 3103 includes features such as a low temperature coefficient of less than 0.01% per °C and LED status indicators for device health and error signaling.

This model has a compact housing with a slim width of 6 mm, suitable for space-constrained installations.

Related Products

Other Products from this brand

Recently Viewed Products

$236.02
$228.93 Save 3%
Tax included
Quantity
Delivery Time Delivered within 0-3 days
  • Global Payments 140+ CountriesGlobal Payments 140+ Countries
  • Global Shipping Fedex/UPS/DHL/Aramex/
BlueDart/Delhivery/DP WorldGlobal Shipping Fedex/UPS/DHL/Aramex/ BlueDart/Delhivery/DP World
  • 24/7 Customer Support Email/Chat/Telephonic Support24/7 Customer Support Email/Chat/Telephonic Support
$236.02
$228.93
Tax included