Eaton FRCdM Series Residual Current Circuit Breaker 40A 3+N-Pole 30mA Type B 500A Breaking 179531 FRCDM-40/4/003-G/BFQ

Category Residual Current Circuit Breaker Brand Eaton Condition New

Specifications

Country of Origin Czech Republic
Range FRCdM
Brand Eaton
Height 80mm
Model 179531 FRCDM-40/4/003-G/BFQ
Depth 70.5mm
Width 76mm
Mount Type DIN Rail
Current Rating 40A
Series FRCdM
Terminal type Screw
Breaking Capacity 500A
Number of Poles 3+N
Standards/Approvals EN 45545-2, IEC/EN 61008, IEC 61373
Rated DC Voltage 220V dc
Tripping Characteristics Type B
Tripping Mechanism Electromagnetic
Trip Sensitivity 30mA
Earth Leakage Protection Type Type B
System Monitoring Preventive information / warning before the RCD trips in case of leakage currents

Key Features

  • Designed to prevent electric shocks and reduce risk of electrical fires.
  • Includes digital monitoring for early detection of leakage currents.
  • Type B tripping characteristics suitable for AC and DC residual current detection.
  • Mounts easily on DIN rail with two latching positions for flexible installation.
  • Thermally stable to withstand normal and high temperature conditions.
  • Complies with EN 45545-2, IEC/EN 61008, IEC 61373 standards.
  • Compact dimensions of 80mm height, 76mm width, and 70.5mm depth.
  • Breaking capacity of 500A supports industrial applications.

Product Description

Eaton 179531 FRCDM-40/4/003-G/BFQ Residual Current Circuit Breaker from the FRCdM series is engineered for advanced earth leakage protection in industrial and commercial electrical systems. Rated for 40A current and a trip sensitivity of 30mA, this 3+N pole device offers dependable safeguarding against electrical shocks and fire hazards.

The unit features Type B tripping characteristics, enabling detection of AC pulsating, DC residual, and smooth DC residual currents up to 1 kHz, making it versatile for applications with variable frequency drives and digital loads. It has an electromagnetic tripping mechanism ensuring precise and timely disconnections in fault conditions.

Designed for ease of installation, the circuit breaker mounts on a DIN rail with two selectable latching positions allowing optimal fitment in control panels. The device includes screw terminals for secure wiring connections and possesses an IP20 rating which guarantees protection against touch and foreign objects larger than 12 mm.

This residual current device is thermally stable and can operate reliably in temperatures ranging from -25°C to +60°C, making it robust for harsh industrial environments. The compact size facilitates integration into existing electrical setups without requiring excessive space.

Compliant with international standards such as EN 45545-2, IEC/EN 61008, and IEC 61373, this Eaton RCD meets stringent safety and performance requirements. Its breaking capacity of 500A supports high fault current interruptions. Additionally, continuous system monitoring provides preventive warnings before the RCD trips, enhancing system reliability.

Provides protection against electric shock and fire risks through sensitive earth leakage detection. Compatible with complex loads including variable frequency drives due to Type B tripping. Easy DIN rail mounting with dual latch positions for flexible installations.

Thermally stable design withstands high temperatures and electrical fire conditions. Compact form factor with screw terminal connections for secure wiring. Complies with multiple international safety and performance standards.

Digital monitoring capability alerts to leakage before tripping occurs. Breaking capacity of 500A suitable for heavy-duty industrial use.

This residual current circuit breaker is ideal for use in industrial automation, electrical distribution, manufacturing plants, and commercial electrical systems requiring advanced leakage protection. Ensure safety and reliability with Eaton FRCdM series devices.

Browse more Residual Current Circuit Breakers and other electrical protection devices at EnvMart for your industrial and commercial needs.

Eaton FRCdM Series Residual Current Circuit Breaker 40A 3+N-Pole 30mA Type B 500A Breaking 179531 FRCDM-40/4/003-G/BFQ
Looking to purchase in bulk?
  • Purchase item in bulk quantity
  • Get best price for your business

Comments (0)

No customer reviews for the moment.

Frequently Asked Questions

This model has a current rating of 40A, making it suitable for various industrial and commercial applications.

It features Type B tripping characteristics, which allows it to detect AC pulsating, DC residual, and smooth DC residual currents up to 1 kHz.

The breaking capacity of this unit is 500A, which supports high fault current interruptions in industrial settings.

It operates reliably within a temperature range of -25°C to +60°C, making it suitable for harsh environments.

This unit mounts easily on a DIN rail and features two selectable latching positions for flexible installation in control panels.

It utilizes screw terminals for secure wiring connections, ensuring reliable electrical contact.

It complies with several international standards, including EN 45545-2, IEC/EN 61008, and IEC 61373, ensuring safety and performance.

The dimensions of this model are 80mm in height, 76mm in width, and 70.5mm in depth, allowing for compact installation.

It includes digital monitoring capabilities that provide preventive warnings before the RCD trips in case of leakage currents.

This model is ideal for use in industrial automation, electrical distribution, manufacturing plants, and commercial electrical systems requiring advanced leakage protection.

It has a configuration of 3+N poles, making it versatile for various electrical systems.

It provides Type B earth leakage protection, suitable for detecting a wide range of leakage currents, including those from variable frequency drives.

Related Products

Other Products from this brand

$1,237.35
$1,200.23 Save 3%
Tax included
Quantity
Delivery Time Delivered within 0-3 days
  • Global Payments 140+ CountriesGlobal Payments 140+ Countries
  • Global Shipping Fedex/UPS/DHL/Aramex/
BlueDart/Delhivery/DP WorldGlobal Shipping Fedex/UPS/DHL/Aramex/ BlueDart/Delhivery/DP World
  • 24/7 Customer Support Email/Chat/Telephonic Support24/7 Customer Support Email/Chat/Telephonic Support
$1,237.35
$1,200.23
Tax included