$69.50
Tax included
×
Product Enquiry
Labtron LTM-A18 Portable Turbidity Meter
World's First Climate Tech Platform | Free Delivery in India | Global Shipping

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase
| Country of Origin | UK |
|---|---|
| Resolution | 0.01 (0 to 100 NTU) / 0.1 (100 to 999 NTU) / 1 (999 to 1100 NTU) |
| Accuracy | ±2% (0 to 500 NTU) / ±3% (501 to 1100 NTU) |
| Brand | Labtron |
| Net Weight | 300 g |
| Operating Temperature | 0°C to 60°C |
| Interface | USB |
| Battery | 1 × 9 V |
| Detector | Silicon Photodiode |
| Memory | Stores up to 100 data sets |
| Model | LTM-A18 |
| Stray Light | Less than 0.02 NTU |
| Gross Weight | 1.2 Kg |
| Type of Product | Turbidity Meter |
| Light Source Type | Infrared-emitting diode |
| Overall Dimension | 180 × 85 × 70 mm |
| Measuring range (NTU) | 0 to 1100 NTU |
| Packing Dimension | 325 × 140 × 270 mm |
| Calibration Standards | 0.02 / 10.00 / 200 / 500 / 1000 or user-defined |
| Light Source Wavelength | 850 nm |
| Power Off Function Type | Manual or Automatic |
| Auto Power Off Time Out | 15 minutes |
| Sample Vial Dimension | 60 (Height) × 25 (Diameter) mm |
Portable Turbidity Meter LTM-A18 offers a measurement range of 0 to 1100 NTU. It provides multi-point calibration using formazin standards and supports four selectable turbidity units (NTU, FNU, EBC, ASBC). The meter offers two modes: single measurement mode and continuous measurement mode. Its infrared-emitting diode and silicon photodiode detector ensure high accuracy. Our meter utilizes the ISO 7027 nephelometric method, which ensures precision and consistency in turbidity measurement.
Applications:
Portable Turbidity Meter LTM-A18 is used in water quality monitoring, environmental testing, and industrial processes to measure turbidity and ensure product quality. It is also applied in the food and beverage, pharmaceutical, and wastewater treatment industries.
Standard Accessories:
Review sent
Your review cannot be sent

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase
| Country of Origin | UK |
|---|---|
| Resolution | 0.01 (0 to 100 NTU) / 0.1 (100 to 999 NTU) / 1 (999 to 1100 NTU) |
| Accuracy | ±2% (0 to 500 NTU) / ±3% (501 to 1100 NTU) |
| Brand | Labtron |
| Net Weight | 300 g |
| Operating Temperature | 0°C to 60°C |
| Interface | USB |
| Battery | 1 × 9 V |
| Detector | Silicon Photodiode |
| Memory | Stores up to 100 data sets |
| Model | LTM-A18 |
| Stray Light | Less than 0.02 NTU |
| Gross Weight | 1.2 Kg |
| Type of Product | Turbidity Meter |
| Light Source Type | Infrared-emitting diode |
| Overall Dimension | 180 × 85 × 70 mm |
| Measuring range (NTU) | 0 to 1100 NTU |
| Packing Dimension | 325 × 140 × 270 mm |
| Calibration Standards | 0.02 / 10.00 / 200 / 500 / 1000 or user-defined |
| Light Source Wavelength | 850 nm |
| Power Off Function Type | Manual or Automatic |
| Auto Power Off Time Out | 15 minutes |
| Sample Vial Dimension | 60 (Height) × 25 (Diameter) mm |
Portable Turbidity Meter LTM-A18 offers a measurement range of 0 to 1100 NTU. It provides multi-point calibration using formazin standards and supports four selectable turbidity units (NTU, FNU, EBC, ASBC). The meter offers two modes: single measurement mode and continuous measurement mode. Its infrared-emitting diode and silicon photodiode detector ensure high accuracy. Our meter utilizes the ISO 7027 nephelometric method, which ensures precision and consistency in turbidity measurement.
Applications:
Portable Turbidity Meter LTM-A18 is used in water quality monitoring, environmental testing, and industrial processes to measure turbidity and ensure product quality. It is also applied in the food and beverage, pharmaceutical, and wastewater treatment industries.