$69.50
Tax included
×
Product Enquiry
Labtron LMWQM-A10 Multi-parameter Water Quality Monitor
World's First Climate Tech Platform | Free Delivery in India | Global Shipping

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase
| Country of Origin | UK |
|---|---|
| Temperature Accuracy | ±0.3 °C |
| Brand | Labtron |
| Power Supply | 186 to 240V / 50/60Hz AC |
| Temperature Resolution | 0.1 °C |
| Temperature range | 0 to 60 °C |
| pH Range | 0.00 to 14.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.1 pH |
| TDS Accuracy | ±1.5% F.S |
| TDS Resolution | 1 mg/L |
| Model | LMWQM-A10 |
| Ambient Temperature (ºC) | 5 to 40 °C | Relative humidity Less than 90% RH |
| Type of Product | Water Quality Monitors |
| Conductivity Accuracy | ±2% F.S |
| Conductivity Resolution | 1 µS/cm |
| Dimensions (L×W×H) | 470 × 250 × 675 mm |
| Residual Chlorine/Chlorine Dioxide Range | 0.00 to 5.00 mg/L |
| Residual Chlorine/Chlorine Dioxide Resolution | ±0.01 mg/L |
| Residual Chlorine/Chlorine Dioxide Accuracy | ±0.05 mg/L or 5% |
| Low Range Turbidity (Laser Method) Range | 0 to 20 NTU |
| Low Range Turbidity (Laser Method) Resolution | 0.001 NTU |
| Low Range Turbidity (Laser Method) Accuracy | ±0.02 NTU or 2% |
| Conductivity Range (Optional) | 0 to 2000 µS/cm (Other ranges available) |
| TDS Range (Optional) | 0 to 1500 mg/L |
| Current Output (Optional) | 4-20 mA (4 channels optional) |
| Relay Output (Optional) | 4-way load AC 220V 10A |
| Monitor Resolution | 1024 × 600 |
Multi-parameter Water Quality Monitor LMWQM-A10 measures residual chlorine from 0.00 to 5.00 mg/L precisely. It features turbidity detection from 0 to 20 NTU, offering a resolution of 0.001 NTU. The device operates within a temperature range of 0 to 60 °C, ensuring reliable performance in diverse environments. Designed for continuous real-time monitoring, it uses advanced sensor technology for intelligent operation and remote reporting. This monitor excels in water treatment, industrial processes, and environmental monitoring, offering consistent, reliable results.
Applications:
Our Multi-parameter Water Quality Monitor LMWQM-A10 ensures optimal water quality in plants, tap stations, and health monitoring. It also supports industrial water processes with reliable performance in demanding environments.
Review sent
Your review cannot be sent

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase
| Country of Origin | UK |
|---|---|
| Temperature Accuracy | ±0.3 °C |
| Brand | Labtron |
| Power Supply | 186 to 240V / 50/60Hz AC |
| Temperature Resolution | 0.1 °C |
| Temperature range | 0 to 60 °C |
| pH Range | 0.00 to 14.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.1 pH |
| TDS Accuracy | ±1.5% F.S |
| TDS Resolution | 1 mg/L |
| Model | LMWQM-A10 |
| Ambient Temperature (ºC) | 5 to 40 °C | Relative humidity Less than 90% RH |
| Type of Product | Water Quality Monitors |
| Conductivity Accuracy | ±2% F.S |
| Conductivity Resolution | 1 µS/cm |
| Dimensions (L×W×H) | 470 × 250 × 675 mm |
| Residual Chlorine/Chlorine Dioxide Range | 0.00 to 5.00 mg/L |
| Residual Chlorine/Chlorine Dioxide Resolution | ±0.01 mg/L |
| Residual Chlorine/Chlorine Dioxide Accuracy | ±0.05 mg/L or 5% |
| Low Range Turbidity (Laser Method) Range | 0 to 20 NTU |
| Low Range Turbidity (Laser Method) Resolution | 0.001 NTU |
| Low Range Turbidity (Laser Method) Accuracy | ±0.02 NTU or 2% |
| Conductivity Range (Optional) | 0 to 2000 µS/cm (Other ranges available) |
| TDS Range (Optional) | 0 to 1500 mg/L |
| Current Output (Optional) | 4-20 mA (4 channels optional) |
| Relay Output (Optional) | 4-way load AC 220V 10A |
| Monitor Resolution | 1024 × 600 |
Multi-parameter Water Quality Monitor LMWQM-A10 measures residual chlorine from 0.00 to 5.00 mg/L precisely. It features turbidity detection from 0 to 20 NTU, offering a resolution of 0.001 NTU. The device operates within a temperature range of 0 to 60 °C, ensuring reliable performance in diverse environments. Designed for continuous real-time monitoring, it uses advanced sensor technology for intelligent operation and remote reporting. This monitor excels in water treatment, industrial processes, and environmental monitoring, offering consistent, reliable results.
Applications:
Our Multi-parameter Water Quality Monitor LMWQM-A10 ensures optimal water quality in plants, tap stations, and health monitoring. It also supports industrial water processes with reliable performance in demanding environments.
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Review sent
Your review cannot be sent
Labtron LMWQM-A10 Multi-parameter Water Quality Monitor
Comments (0)
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent