| Brand | Labtron |
|---|---|
| Power | 220V ± 10% / 50 Hz / 250 W |
| Pressure | ± 0.02 MPa |
| Model | LHLC-B10 |
| Flow Rate Range | 0.001 - 9.999 mL/min |
| Flow Rate Precision | ± 5% |
| High Pressure Pump | High Pressure Gradient Pump |
| Quantitative Repeatability | RSD 6 ≤ 0.2% |
| Size (W × H × D) | 520 × 420 × 160 mm |
| UV Detector Wavelength Range | 190 - 680 nm |
| UV Detector Flow Cell | 8 μL |
| UV Detector Baseline Noise | ≤ ± 2 × 10⁻⁵ AU (Methyl alcohol / 1 mL/min / 254 nm / 20℃) |
| UV Detector Limit of Detection | ≤ 2 × 10⁻⁹ g/mL (Naphthalene methyl alcohol solvent) |
| Peak Operating Pressure | 45 MPa / Stainless steel pump |
| Flow Rate Repeatability | RSD ≤ 0.1% |
| UV Detector Wavelength Error | ≤ ± 1 nm |
| UV Detector Wavelength Repeatability | 0.2 nm |
| UV Detector Drift | ≤ 5 × 10⁻⁴ AU/h (Methyl alcohol / 1 mL/min / 254 nm / 20℃) |
| Automatic Injector Sample Value | Maximum 2 mL / 6 × 25 equal to 150 units |
| Automatic Injector Sample Volume | 0 - 1 mL / adjustable |
| Automatic Injector Sample Residual | Less than 0.02% |
| Column Oven Temperature Control | Room temperature ± 5℃ - 80℃ |
| Column Oven Constant Temperature Accuracy | ± 1℃ |
| Column Oven Constant Temperature Precision | ≤ 0.1℃ |
| Column Oven Temperature Setting Resolution Ratio | 0.1℃ |
| Quantitative Analysis | RSD 6 ≤ 0.2% |
| Sample Residual | ≤ 0.01% |
| Gradient Error | ≤ 0.01% |
HPLC System is equipped with an advanced high-pressure injection technique. The detector features a 24-bit AD transducer, ensuring low noise, low drift, and high sensitivity. This system allows for convenient sample input volume adjustment and is designed with a dual piston reciprocating pump and a series pump for consistent and stable flow.
Applications
This gradient HPLC system is widely used in medicine analysis, protein content detection in food, environmental analysis, oil and chemical analysis, and scientific research studies.
Review sent
Your review cannot be sent

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase
| Brand | Labtron |
|---|---|
| Power | 220V ± 10% / 50 Hz / 250 W |
| Pressure | ± 0.02 MPa |
| Model | LHLC-B10 |
| Flow Rate Range | 0.001 - 9.999 mL/min |
| Flow Rate Precision | ± 5% |
| High Pressure Pump | High Pressure Gradient Pump |
| Quantitative Repeatability | RSD 6 ≤ 0.2% |
| Size (W × H × D) | 520 × 420 × 160 mm |
| UV Detector Wavelength Range | 190 - 680 nm |
| UV Detector Flow Cell | 8 μL |
| UV Detector Baseline Noise | ≤ ± 2 × 10⁻⁵ AU (Methyl alcohol / 1 mL/min / 254 nm / 20℃) |
| UV Detector Limit of Detection | ≤ 2 × 10⁻⁹ g/mL (Naphthalene methyl alcohol solvent) |
| Peak Operating Pressure | 45 MPa / Stainless steel pump |
| Flow Rate Repeatability | RSD ≤ 0.1% |
| UV Detector Wavelength Error | ≤ ± 1 nm |
| UV Detector Wavelength Repeatability | 0.2 nm |
| UV Detector Drift | ≤ 5 × 10⁻⁴ AU/h (Methyl alcohol / 1 mL/min / 254 nm / 20℃) |
| Automatic Injector Sample Value | Maximum 2 mL / 6 × 25 equal to 150 units |
| Automatic Injector Sample Volume | 0 - 1 mL / adjustable |
| Automatic Injector Sample Residual | Less than 0.02% |
| Column Oven Temperature Control | Room temperature ± 5℃ - 80℃ |
| Column Oven Constant Temperature Accuracy | ± 1℃ |
| Column Oven Constant Temperature Precision | ≤ 0.1℃ |
| Column Oven Temperature Setting Resolution Ratio | 0.1℃ |
| Quantitative Analysis | RSD 6 ≤ 0.2% |
| Sample Residual | ≤ 0.01% |
| Gradient Error | ≤ 0.01% |
HPLC System is equipped with an advanced high-pressure injection technique. The detector features a 24-bit AD transducer, ensuring low noise, low drift, and high sensitivity. This system allows for convenient sample input volume adjustment and is designed with a dual piston reciprocating pump and a series pump for consistent and stable flow.
Applications
This gradient HPLC system is widely used in medicine analysis, protein content detection in food, environmental analysis, oil and chemical analysis, and scientific research studies.
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Review sent
Your review cannot be sent
Labtron LHLC-B10 HPLC System
Comments (0)
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent