| Brand | Labtron |
|---|---|
| Model | LHLC-A11 |
| Pressure Range | ≤ 0.5 MPa (0 - 42 MPa) |
| Flow Rate Range | 0.001 - 9.999 mL / min (0.001 mL / min increments) |
| Flow Rate Precision | RSD Less than 0.06 % |
| Qualitative Analysis | RSD 6 ≤ 0.1 % (naphthalene methyl alcohol solvent) |
| Mixing Accuracy | ± 1 % |
| Mixing Precision | ± 0.2 % |
| High Pressure Pump | Two sets of pump |
| Pulsation | ≤ 0.1 MPa (flow rate 1 mL / min / Pressure 5 - 10 MPa) |
| Quantitative Repeatability | RSD 6 ≤ 0.3 % (naphthalene methyl alcohol solvent) |
| Flow Rate Setting Error | Ss ≤ 2 % (1 mL / min water / 5 - 10 MPa / room temperature) |
| Size (W × H × D) | 450 × 300 × 160 mm |
| UV Detector Wavelength Range | 190 - 680 nm |
| UV Detector Flow Cell | 8 μL |
| UV Detector Spectrum Band Width | 8 nm |
| UV Detector Baseline Noise | ≤ ± 0.25 × 10⁻⁵ AU (empty cell) |
| UV Detector Wavelength Accuracy | ± 1 nm |
| UV Detector Baseline Drift | ≤ ± 0.4 × 10⁻⁴ AU (empty cell) |
| UV Detector Wavelength Precision | Less than 0.1 nm |
| UV Detector Limit of Detection | 3 × 10⁻⁹ g / mL (naphthalene methyl alcohol solvent) |
| UV Detector Size (W × H × D) | 450 × 300 × 160 mm |
| Air Tightness of the Pump | Pressure 42 MPa / 10 min time / Pressure drop Less than 0.5 MPa |
HPLC Gradient System is equipped with 2 sets of high-pressure constant-current pumps and a UV detector. Its microprocessor reciprocating plunger pump offers functions like high working pressure and low pulse rate, providing stable and precise performance. This gradient HPLC model is suitable for both conventional analysis and micro-flow analysis, making it versatile for a range of analytical needs.
Applications
This HPLC system has applications in the fields of biochemistry, chemistry, pharmacology, and is used for chemical analysis, poison analysis, protein food detection, medicine testing, and polymer and environmental analysis.
Review sent
Your review cannot be sent

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase
| Brand | Labtron |
|---|---|
| Model | LHLC-A11 |
| Pressure Range | ≤ 0.5 MPa (0 - 42 MPa) |
| Flow Rate Range | 0.001 - 9.999 mL / min (0.001 mL / min increments) |
| Flow Rate Precision | RSD Less than 0.06 % |
| Qualitative Analysis | RSD 6 ≤ 0.1 % (naphthalene methyl alcohol solvent) |
| Mixing Accuracy | ± 1 % |
| Mixing Precision | ± 0.2 % |
| High Pressure Pump | Two sets of pump |
| Pulsation | ≤ 0.1 MPa (flow rate 1 mL / min / Pressure 5 - 10 MPa) |
| Quantitative Repeatability | RSD 6 ≤ 0.3 % (naphthalene methyl alcohol solvent) |
| Flow Rate Setting Error | Ss ≤ 2 % (1 mL / min water / 5 - 10 MPa / room temperature) |
| Size (W × H × D) | 450 × 300 × 160 mm |
| UV Detector Wavelength Range | 190 - 680 nm |
| UV Detector Flow Cell | 8 μL |
| UV Detector Spectrum Band Width | 8 nm |
| UV Detector Baseline Noise | ≤ ± 0.25 × 10⁻⁵ AU (empty cell) |
| UV Detector Wavelength Accuracy | ± 1 nm |
| UV Detector Baseline Drift | ≤ ± 0.4 × 10⁻⁴ AU (empty cell) |
| UV Detector Wavelength Precision | Less than 0.1 nm |
| UV Detector Limit of Detection | 3 × 10⁻⁹ g / mL (naphthalene methyl alcohol solvent) |
| UV Detector Size (W × H × D) | 450 × 300 × 160 mm |
| Air Tightness of the Pump | Pressure 42 MPa / 10 min time / Pressure drop Less than 0.5 MPa |
HPLC Gradient System is equipped with 2 sets of high-pressure constant-current pumps and a UV detector. Its microprocessor reciprocating plunger pump offers functions like high working pressure and low pulse rate, providing stable and precise performance. This gradient HPLC model is suitable for both conventional analysis and micro-flow analysis, making it versatile for a range of analytical needs.
Applications
This HPLC system has applications in the fields of biochemistry, chemistry, pharmacology, and is used for chemical analysis, poison analysis, protein food detection, medicine testing, and polymer and environmental analysis.
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Review sent
Your review cannot be sent
Labtron LHLC-A11 HPLC System
Comments (0)
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent