$69.50
Tax included
×
Product Enquiry
Labtron LCIS-A22 Chemiluminescence Imaging System
World's First Climate Tech Platform | Free Delivery in India | Global Shipping

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase
| Resolution | 6.05 Megapixels / 2750 × 2200 |
|---|---|
| Display | 10.1 inch touch screen display |
| Brand | Labtron |
| Dimension | 560 × 480 × 780 mm + 380 × 350 × 490 mm |
| Light Source | LED Epi-White light × 2 / UV-Transilluminator (302 nm) / White-LED Transilluminator |
| Model | LCIS-A22 |
| SOFTWARE | Image acquisition and analysis software |
| Gross Weight | 39 kg |
| Lens | F0.8 motorized lens |
| Dynamic Range | 4 order of magnitude |
| Pixel Density | 16-bit (65536 Grey scales) |
| Readout Noise | Less than 5.5e- RMS |
| Pixel Size | 4.54 × 4.54 µm |
| Quantum Efficiency | ≥ 75% |
| Filter Wheel | 8 Sockets Filter Wheel |
| Dark Current | 0.0003 e/p/s |
| Standard Filter | 590 nm filter |
| Max Image Area | 260 × 210 mm |
| Cooling Temperature | -30°C |
| CCD Sensor Size | 12.49 × 9.99 mm |
Chemiluminescence Imaging System LCIS-A22 is an advanced integrated device featuring a 10.1-inch touch screen display, designed for imaging chemiluminescence gels with exceptionally high quantum efficiency. It is equipped with a 12.49 × 9.99 mm CCD sensor, 6.05 MP resolution, F0.8 motorized lens, and a -30˚C cooling temperature to enhance sensitivity and reduce noise during long exposure times. The 16-bit (65536 Grey Scales) CCD camera allows detection of weaker signals with higher sensitivity and a wider linear range. This system is optimized for RNA, DNA, protein, and chemiluminescence imaging, ensuring precise and efficient documentation.
Applications
Chemiluminescence Imaging System is widely used in genetic engineering, biotechnology, and molecular biology to obtain high-quality images of DNA/RNA bands. It is also applicable in protein detection, ELISA plate reading, and chemiluminescence analysis for research and diagnostic purposes.
Optional Accessories
Chemiluminescence Image System Software
Review sent
Your review cannot be sent

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase
| Resolution | 6.05 Megapixels / 2750 × 2200 |
|---|---|
| Display | 10.1 inch touch screen display |
| Brand | Labtron |
| Dimension | 560 × 480 × 780 mm + 380 × 350 × 490 mm |
| Light Source | LED Epi-White light × 2 / UV-Transilluminator (302 nm) / White-LED Transilluminator |
| Model | LCIS-A22 |
| SOFTWARE | Image acquisition and analysis software |
| Gross Weight | 39 kg |
| Lens | F0.8 motorized lens |
| Dynamic Range | 4 order of magnitude |
| Pixel Density | 16-bit (65536 Grey scales) |
| Readout Noise | Less than 5.5e- RMS |
| Pixel Size | 4.54 × 4.54 µm |
| Quantum Efficiency | ≥ 75% |
| Filter Wheel | 8 Sockets Filter Wheel |
| Dark Current | 0.0003 e/p/s |
| Standard Filter | 590 nm filter |
| Max Image Area | 260 × 210 mm |
| Cooling Temperature | -30°C |
| CCD Sensor Size | 12.49 × 9.99 mm |
Chemiluminescence Imaging System LCIS-A22 is an advanced integrated device featuring a 10.1-inch touch screen display, designed for imaging chemiluminescence gels with exceptionally high quantum efficiency. It is equipped with a 12.49 × 9.99 mm CCD sensor, 6.05 MP resolution, F0.8 motorized lens, and a -30˚C cooling temperature to enhance sensitivity and reduce noise during long exposure times. The 16-bit (65536 Grey Scales) CCD camera allows detection of weaker signals with higher sensitivity and a wider linear range. This system is optimized for RNA, DNA, protein, and chemiluminescence imaging, ensuring precise and efficient documentation.
Applications
Chemiluminescence Imaging System is widely used in genetic engineering, biotechnology, and molecular biology to obtain high-quality images of DNA/RNA bands. It is also applicable in protein detection, ELISA plate reading, and chemiluminescence analysis for research and diagnostic purposes.
Optional Accessories
Chemiluminescence Image System Software
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Review sent
Your review cannot be sent
Labtron LCIS-A22 Chemiluminescence Imaging System
Comments (0)
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent