Legrand DX3 Series Residual Current Device 20A 1-Pole 30 mA Type AC 230V ac 4 111 59

Category Residual Current Device Brand Legrand Condition New

Specifications

Country of Origin France
Range DX
Brand Legrand
Model 4 111 59
Connection Type Screw / Screw
Mount Type DIN Rail
Current Rating 20A
Series DX3
Number of Poles 1
Rated AC Voltage 230V ac
Tripping Characteristics Type AC
Trip Sensitivity 30mA
Break Time Instantaneous
AC type Detect AC components faults
Legrand MCB2P, 20A Curve CBrand Legrand

Key Features

  • This device has a current rating of 20A with a single pole configuration.
  • It features a trip sensitivity of 30 mA for enhanced safety.
  • Mounting is designed for DIN rail installations.
  • Uses Type AC tripping characteristics suitable for AC fault detection.
  • Complies with IEC 61009-1, IEC 61008-1, IEC 60947-2 standards ensuring high quality and safety.
  • Offers instantaneous break time for rapid fault disconnection.
  • Rated for operation at 230V AC voltage.
  • Designed for both industrial and residential electrical installations.

Product Description

Legrand 4 111 59 Residual Current Device (RCD) from the DX3 Series is a high-quality 20A, 1-Pole device with 30 mA trip sensitivity and Type AC tripping characteristic rated for 230V AC operation. It is built to provide efficient and reliable protection for electrical circuits by detecting AC fault currents effectively, making it suitable for industrial, commercial, and residential applications.

This RCD is designed for DIN rail mounting, facilitating easy integration with existing electrical panels and switchboards. It features a screw-type connection to ensure a secure and stable electrical interface. The device has an instantaneous break time, which ensures a rapid response to electrical faults for enhanced electrical safety.

Manufactured to meet rigorous standards including IEC 61009-1, IEC 61008-1, IEC 60947-2, IEC 60898-1, and VDE certifications, the device guarantees compliance with international safety and performance criteria. Additionally, the RCD supports use of traditional supply busbars with a breaking capacity of 10 kA, providing robustness in demanding electrical environments.

The Legrand DX3 Series RCD offers a compact form factor spanning four modules, making it a versatile choice for various electrical protection needs. This product is ideal for applications that require reliable fault detection and enhanced electrical safety monitoring.

This RCD has a current rating of 20A with one pole for single-phase applications. The 30 mA trip sensitivity ensures protection against earth leakage currents. Type AC tripping characteristic is suitable for detecting AC fault currents only.

DIN rail mounting provides ease of installation and compatibility with standard panels. Instantaneous break time facilitates fast disconnection during faults. Meets multiple safety standards for industrial and residential installations.

Uses screw connections for secure wiring. Meets a breaking capacity of 10 kA for demanding electrical environments.

Choose the Legrand DX3 Series Residual Current Device for dependable electrical protection, designed for industrial, residential, and commercial usage. Explore our wide range of electrical protection products to find the perfect fit for your application needs.

Legrand DX3 Series Residual Current Device 20A 1-Pole 30 mA Type AC 230V ac 4 111 59
Looking to purchase in bulk?
  • Purchase item in bulk quantity
  • Get best price for your business

Comments (0)

No customer reviews for the moment.

Frequently Asked Questions

This Residual Current Device has a current rating of 20A.

It features a trip sensitivity of 30 mA, which provides enhanced safety by detecting earth leakage currents.

This model is designed for DIN rail mounting, allowing for easy integration into existing electrical panels.

It utilizes Type AC tripping characteristics, which are suitable for detecting AC fault currents.

The device is rated for operation at 230V AC voltage.

It offers an instantaneous break time for rapid disconnection during electrical faults.

It uses screw-type connections, ensuring a secure and stable electrical interface.

The RCD complies with multiple standards including IEC 61009-1, IEC 61008-1, and IEC 60947-2, ensuring high quality and safety.

This model has a single pole configuration, making it suitable for single-phase applications.

It supports a breaking capacity of 10 kA, making it suitable for demanding electrical environments.

This Residual Current Device is suitable for industrial, commercial, and residential applications, providing reliable electrical protection.

The country of origin for this Residual Current Device is France.

Related Products

Other Products from this brand

$587.50
$569.87 Save 3%
Tax included
Quantity
Delivery Time Delivered within 0-3 days
  • Global Payments 140+ CountriesGlobal Payments 140+ Countries
  • Global Shipping Fedex/UPS/DHL/Aramex/
BlueDart/Delhivery/DP WorldGlobal Shipping Fedex/UPS/DHL/Aramex/ BlueDart/Delhivery/DP World
  • 24/7 Customer Support Email/Chat/Telephonic Support24/7 Customer Support Email/Chat/Telephonic Support
$587.50
$569.87
Tax included