Specifications

Weight 20.5 kg
Operating voltage 100 - 240 V VAC 50 / 60 Hz (autoranging)
Repeatability Less Than 1 % short term (24 hours) 5 % long term at constant temperature & humidity
Power Consumption 165 VA maximum (typical at start-up) 95 VA after warm-up
Response time Less Than 5 seconds
Pressure Maximum altitude 3000 m above sea level
Linearity Within 0.15 % of full scale
Flow Rate Variable dependent on Dilution Mass Flow Controller installed
Zero drift Less Than 0.6 % per year
Dilution gas inputs 1 standard 100 - 200 kPa (g) (2 optional)
Source gas inputs 4 standard 100 - 200 kPa (g) (8 optional)
Dilution mass flow controller 10 SLPM 0 Deg 1 ATM (std) 1 SLPM 2 SLPM 5 SLPM or 20 SLPM (optional) 2nd MFC (optional)
Source mass flow controller 50 SCCM 0 Deg 1 ATM (std) 10 SCCM 20 SCCM 100 SCCM 500 SCCM or 1 SLPM 2 SLPM (optional) 2nd MFC (optional)
Flow accuracy (constant temp) Within 1 % of full scale
Flow repeatability Within 0.15 % of full scale
Operating gas pressure 100 - 200 kPa
Output manifold 4 output ports standard
Dilution ratio Variable 10 1 to 2000 1 (std configuration)
Case dimensions rack length 597 mm (23.5 inch) (front to rear)
Total length (with latch release) 638 mm (25.1 inch)
Chassis width 418 mm (16.5 inch)
Front panel width 429 mm (16.9 inch)
Chassis height 163 mm / uses 4RU (6.4 inch)
Front panel height 175 mm (6.9 inch)
Operating conditions ambient temperature range 0 - 45 C (32 - 104 F) 20 - 35 C for optimum performance
Output concentration 3 ppb to 5000 ppb

Key Features

  • All the calibration ability and ease of use found in the Serinus Cal 1000
  • Internal ozone generator produces 3 ppm to 5 ppm of ozone