Filling Machine
Serinus 30 Carbon Monoxide Analyser
Quantity
5/5
Free Delivery in India | Lowest Global Shipping Charges
- Genuine Products
- Global Shipping
- Secured Payments
Save up to 28% with GST Input
Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries
100% Original Products
Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase
Serinus 30 Carbon Monoxide Analyser
Specifications
Power | 100 - 240 VAC| 50 - 60 Hz (autoranging) |
---|---|
Weight | 17.8 kg |
Dimensions | 429 x 175 x 638 mm |
Range | 0 to 200 ppm (autoranging) |
Temperature range | 0 to 40 C |
Power Consumption | 260 VA (max at start-up) 150 VA (nominal) |
Response time | 60 seconds to 95 % |
Linearity | Less Than 1 % of full scale (0 - 50 ppm) |
Noise | Less Than 0.02 ppm or 0.2 % of concentration reading whichever is greater |
Zero drift | 24 hours Less Than 0.1 ppm 7 days Less Than 0.1 ppm |
Lower detectable limit | Less Than 0.04 ppm |
Precision | 0.1 ppm or 0.1 % of reading whichever is greater |
Span drift | 7 days Less Than 0.5 % of reading or 0.1 ppm whichever is greater |
Concentration units | mg/m3 | g/m3 | ng/m3 | ppm| ppb or ppt |
STP reference | 0 C| 20 C| 25 C at 101.3 kPa |
Sample flow rate | 1000 cc/min |
Rack Spacing | 3.5 RU |
Key Features
- Bulk Quantities Available
Product Details
The Serinus 30 carbon monoxide (CO)analyser delivers precise and reliableperformance at excellent value. It usesproven NDIR gas filter correlationtechnology to measure CO in ambient air(LDL < 40 ppb, range 0 to 200 ppm).APPROVALS US EPA approval (RFCA0509174) EN approval TV (0000040203-02) EN approval MCERTS (MC100166/07) Australian Standard (AS 3580.7.1-2011) Russian approval (56262-14) French approval LSCQA Ukraine approval (12/3/B/24/295-17) Chinese Pattern Approval (JJF1364-2012) Korean approval NIER (AACMS-2017-02)BENEFITSThe Serinus range of analysers have been designed using ourexperience and knowledge gained from operating large air qualitymonitoring networks for more than 40 years. The result, instrumentsthat integrate seamlessly into continuous monitoring networks. Reliable performance complemented with a two year warranty Minimise time spent on site performing maintenance throughsuperior remote instrument control, diagnostic viewing andcalibration Comprehensive data logging and remote viewing of over 200operational parameters Versatile interfacing through RS232, USB, Bluetooth, analog anddigital I/O and optional TCP/IP Easy setup through an intuitive menu system, advanced GUI and alarge alphanumeric keypad with tactile keys Instant status indication via illuminated instrument status lightbuttons on the front panel Removable flash memory stores ~10 years of data, including up to12 individual parameters and event logs. Operational parameterscan also be transferred to memory for easy retrieval Latest firmware updates can easily be installed using the USBflash memory drive Programming, viewing, downloading and emailing of data ismade even simpler using Bluetooth connectivity combined withthe Ecotech Serinus Remote Android App Built-in digital display measuring values and having function ofmeasuring values transferred to graphical trend display Enhanced operator safety through the use of 12 VDC internalvoltages Reduced cost of spare parts, accessories and consumable itemsthrough extensive use of standard components across theSerinus range Rack slide design makes accessing internal components andremoving the analyser from a rack cabinet easy AQMS power usage can be reduced due to the instruments lowpower demand and its ability to operate over a widetemperature range.DATA LOGGING 8 GB removable USB flash memory drive that stores the internaldata logger, event log, automatic/manual configuration backupand automatic/manual parameter list save Internal data logger (can log up to 12 of 200+ parameters) Logger interval (1 second to 24 hours) Storage capacity ~ 10 years (set to 1 minute interval).OPTIONS & ACCESSORIES TCP/IP Network Port Dual Sample (particulate) Filter High Pressure Span (for direct cylinder calibration) High Pressure Zero (for direct cylinder calibration) Internal DC Pump (long life, low power, minimal maintenance) Integrated CO2 Sensor (range: 0 - 2000 ppm, accuracy: 2 %) Metric Fitting Kit (to connect 6 mm tube to rear ports) 19 Rack Mount Kit External Pump (240 or 110 VAC) Annual Maintenance Kit Printed User Manual (a soft copy of the user manual is suppliedon the ACOEM Ecotech resources USB stick with each analyser).COMMUNICATION #1 RS232 port (supports all protocols*) #2 RS232 port (supports all protocols* and multidrop) USB port (Advanced protocol only) Bluetooth (Advanced protocol only) TCP/IP network port (optional, supports all protocols*).*Available protocols: Modbus (RTU/TCP), Bayern Hessen, EC9800 or AdvancedCOMMUNICATION ANALOG & DIGITAL I/O PORT: 3 x analog outputs (current or voltage), 12 bit resolution userdefinable range (between two user specified points)Current range: 0 - 20 mA, 2 - 20 mA or 4 - 20 mAVoltage range: 0 - 5 V, 0 - 10 V (voltage offset of 0 V, 0.25 V or 0.5 V) 3 x analog inputs (scalable), 0 - 5 V, 16 bit resolution 8 x logic level digital control inputs 8 x open collector digital status outputs.
Other products from this brand
Nephelometer
Nephelometer
Nephelometer
Recommended Products
Gas Analyzer
Gas Analyzer
Gas Analyzer
Gas Analyzer
Gas Analyzer
Quantity
24/7 Customer Support
Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries
# Lowest Price Challenge
If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon