Serinus Cal 1000
Quantity
Specifications
Weight | 18.2 kg |
---|---|
Operating voltage | 100 - 240 V VAC 50 / 60 Hz (autoranging) |
Power Consumption | 165 VA maximum (typical at start-up) 95 VA after warm-up |
Response time | Less Than 5 seconds |
Pressure | Maximum altitude 3000 m above sea level |
Linearity | Within 0.15 % of full scale |
Zero drift | Less Than 0.6 % per year |
Dilution gas inputs | 1 standard 100 - 200 kPa (g) (2 optional) |
Source gas inputs | 4 standard 100 - 200 kPa (g) (8 optional) |
Dilution mass flow controller | 10 SLPM 0 Deg 1 ATM (std) 1 SLPM 2 SLPM 5 SLPM or 20 SLPM (optional) 2nd MFC (optional) |
Source mass flow controller | 50 SCCM 0 Deg 1 ATM (std) 10 SCCM 20 SCCM 100 SCCM 500 SCCM or 1 SLPM 2 SLPM (optional) 2nd MFC (optional) |
Flow accuracy (constant temp) | Within 1 % of full scale |
Flow repeatability | Within 0.15 % of full scale |
Operating gas pressure | 100 - 200 kPa |
Output manifold | 4 output ports standard |
Dilution ratio | Variable 10 1 to 2000 1 (std configuration) |
Case dimensions rack length | 597 mm (23.5 inch) (front to rear) |
Total length (with latch release) | 638 mm (25.1 inch) |
Chassis width | 418 mm (16.5 inch) |
Front panel width | 429 mm (16.9 inch) |
Chassis height | 163 mm / uses 4RU (6.4 inch) |
Front panel height | 175 mm (6.9 inch) |
Operating conditions ambient temperature range | 0 - 45 C (32 - 104 F) 20 - 35 C for optimum performance |
Key Features
- Performs single and multi-point calibrations using the Serinus Calibrators precision mass flow controllers, for the utmost confidence in the results
- Performs calibration manually through user interface or remotely via RS232, USB networks or digital inputs
Product Details
The Serinus Cal 1000 performs gas dilution calibrations and is used in conjunction with regulatory traceable gases and a zero-air generator.The most cost-effective solution, the Serinus Cal 1000 allows the most up-to-date calibrations technology to be available to all.
- Designed and developed with wide-ranging customer input for easy, intuitive, accurate use