Hanna Electrode Storage Solution, 500 mL, Laboratory Grade, HI70300L

Category Storage Solutions Brand Hanna Condition New

Specifications

Country of Origin India
Package Contents 1 Bottle of 500 mL Electrode Storage Solution
Brand Hanna
Model HI70300L
Certificate of Analysis No
Recommended Use pH and ORP electrodes
Application Electrode maintenance, laboratory, industrial, research
Volume 500 mL
Packaging Airtight bottle with tamper-proof seal
Quality Control Lot number and expiration date
Product Condition New
MPN HI70300L
Solution Type Electrode Storage Solution

Key Features

Hanna HI70300L Electrode Storage Solution is a 500 mL laboratory-grade solution for maintaining pH and ORP electrodes in optimal condition.

  • Specially formulated for the storage of pH and ORP electrodes.
  • Maintains glass membrane hydration to ensure precise measurements.
  • Prevents microbial growth and reduces osmotic effects on reference electrolyte.
  • Enhances electrode lifespan and performance when used regularly.
  • Packaged in an airtight bottle with a tamper-proof seal for solution integrity.
  • Includes lot number and expiration date for quality assurance and traceability.
  • Ideal for rehydrating electrodes after cleaning or extended storage.
  • Suitable for laboratory, environmental, and scientific research applications.

Product Description

Hanna HI70300L Electrode Storage Solution, 500 mL, is a laboratory-grade reagent specifically prepared to maintain the reliability and performance of pH and ORP electrodes. Keeping the glass membrane of electrodes hydrated and the reference junction clear is critical for ensuring accurate and fast measurements in laboratory and industrial environments.

This specialized storage solution is designed to minimize microbial growth and prevent adverse effects due to diffusion and osmotic pressure. Never store pH or ORP electrodes in distilled or deionized water, as this can reduce the sensor lifespan. After using cleaning solutions, soak the electrodes in HI70300L for at least one hour before measurements to rehydrate and maximize accuracy.

  • Special formulation to minimize microbial growth and osmotic or diffusion effects between the solution and inner reference electrolyte.
  • Maintains optimal hydration of the glass membrane and reference junction of pH/ORP electrodes.
  • Provides a stable environment to enhance electrode lifespan.
  • Packaged in a 500 mL air-tight, tamper-proof bottle for laboratory use.
  • Clearly labeled with expiration date and lot number for quality control.
  • Ideal for laboratories, environmental monitoring, scientific research, and industrial process control where pH or ORP measurement is critical.
  • Recommended for rehydration after cleaning or prolonged dry storage.
  • Should not be substituted with distilled or deionized water for storage.

Each bottle of HI70300L has a five-year expiration period from the manufacturing date (unopened). This ensures quality and effectiveness for reliable laboratory and field applications. Explore our full range of laboratory chemicals and solutions under Storage Solutions and Hanna on EnvMart.

Comments (0)

Frequently Asked Questions

The Hanna HI70300L is specifically formulated to maintain the hydration of pH and ORP electrodes, ensuring accurate measurements and extending their lifespan.

After cleaning, soak the electrodes in HI70300L for at least one hour to rehydrate them before taking measurements.

No, storing electrodes in distilled or deionized water can reduce their lifespan. Use HI70300L instead for optimal performance.

The HI70300L solution has a five-year expiration period from the manufacturing date when unopened, ensuring its effectiveness.

HI70300L is specifically designed for pH and ORP electrodes, making it ideal for those types of sensors.

By maintaining optimal hydration and minimizing microbial growth, HI70300L enhances the lifespan and accuracy of electrodes.

The solution is packaged in a 500 mL airtight, tamper-proof bottle to ensure solution integrity and quality.

Yes, HI70300L is suitable for laboratory, environmental, and scientific research applications where pH or ORP measurement is critical.

Store HI70300L in a cool, dry place, and ensure the bottle is tightly sealed to maintain solution integrity.

If the HI70300L solution has expired, it is recommended to dispose of it and purchase a new bottle to ensure reliable performance.