| Country of Origin | UK |
|---|---|
| Temperature Accuracy | ±1°C |
| Brand | Labtron |
| Temperature Resolution | 0.1°C |
| Temperature range | 0 to 105°C / 32 to 221°F |
| TDS Accuracy | ±1% F.S. |
| Model | LBCM-A14 |
| Power Requirements | DC 9V / using AC adapter / AC 220V / 50Hz |
| Weight | 1.5 KG |
| Type of Product | Conductivity Meter |
| Temperature Coefficient | 0.0 to 10.0% per °C |
| Cell Constant | K equal to 0.1 / 1 / 10 |
| Conductivity Accuracy | ±1% F.S. |
| Conductivity Resolution | 0.001 / 0.1 / 1 µS/cm |
| TDS Factor | 0.01 to 1.00 (default 0.5) |
| Dimensions (L × W × H) | 210 x 205 x 75 mm |
| Conductivity Measurement Range | 0.01-20.0 / 200.0 / 2000 µS/cm / 20.00 / 200.0 mS/cm |
| Conductivity Calibration Solutions | 10 µS/cm / 84 µS/cm / 1413 µS/cm / 12.88 mS/cm / 111.8 mS/cm |
| Conductivity Calibration Points | 1 to 3 points |
| Temperature Compensation Range & Mode | Manual or automatic / 0 to 100°C / 32 to 212°F |
| TDS Measurement Range | 0 to 10.00 / 100.0 / 1000 ppm / 10.00 / 100 ppt (Max 200 ppt) |
| TDS Calibration Points | 3 points |
| Temperature Calibration Points | 1 point |
Benchtop Conductivity Meter LBCM-A14 with 1 to 3 points push button conductivity calibration, automatically recognizes calibration standards. With the setup menu, it sets 6 parameters, including calibration points, temperature units, and others. The large LCD display shows settings and measurement values. Temperature calibration by manual method improves the accuracy of the conductivity meter.
Applications:
Used to test conductivity, TDS values of different types of liquids such as pure, hard/low conductivity water, distilled water. Also used in water purification labs, water testing and management plants, and water processing and packaging units for quality and research purposes.
Standard Accessories:
Optional Accessories:
Review sent
Your review cannot be sent

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase
| Country of Origin | UK |
|---|---|
| Temperature Accuracy | ±1°C |
| Brand | Labtron |
| Temperature Resolution | 0.1°C |
| Temperature range | 0 to 105°C / 32 to 221°F |
| TDS Accuracy | ±1% F.S. |
| Model | LBCM-A14 |
| Power Requirements | DC 9V / using AC adapter / AC 220V / 50Hz |
| Weight | 1.5 KG |
| Type of Product | Conductivity Meter |
| Temperature Coefficient | 0.0 to 10.0% per °C |
| Cell Constant | K equal to 0.1 / 1 / 10 |
| Conductivity Accuracy | ±1% F.S. |
| Conductivity Resolution | 0.001 / 0.1 / 1 µS/cm |
| TDS Factor | 0.01 to 1.00 (default 0.5) |
| Dimensions (L × W × H) | 210 x 205 x 75 mm |
| Conductivity Measurement Range | 0.01-20.0 / 200.0 / 2000 µS/cm / 20.00 / 200.0 mS/cm |
| Conductivity Calibration Solutions | 10 µS/cm / 84 µS/cm / 1413 µS/cm / 12.88 mS/cm / 111.8 mS/cm |
| Conductivity Calibration Points | 1 to 3 points |
| Temperature Compensation Range & Mode | Manual or automatic / 0 to 100°C / 32 to 212°F |
| TDS Measurement Range | 0 to 10.00 / 100.0 / 1000 ppm / 10.00 / 100 ppt (Max 200 ppt) |
| TDS Calibration Points | 3 points |
| Temperature Calibration Points | 1 point |
Benchtop Conductivity Meter LBCM-A14 with 1 to 3 points push button conductivity calibration, automatically recognizes calibration standards. With the setup menu, it sets 6 parameters, including calibration points, temperature units, and others. The large LCD display shows settings and measurement values. Temperature calibration by manual method improves the accuracy of the conductivity meter.
Applications:
Used to test conductivity, TDS values of different types of liquids such as pure, hard/low conductivity water, distilled water. Also used in water purification labs, water testing and management plants, and water processing and packaging units for quality and research purposes.
Standard Accessories:
Optional Accessories:
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Review sent
Your review cannot be sent
Labtron LBCM-A14 Benchtop Conductivity Meter
Comments (0)
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent