| Country of Origin | UK |
|---|---|
| Power Consumption | 48 to 72 W |
| Brand | Labtron |
| Power Supply | 100 to 240V / 50/60 Hz |
| Model | LDIN-B11 |
| Tank Capacity | 40 L |
| Type of Product | Water Purification System |
| Water Output Rate | 90 L/hr |
| Inlet Water Pressure | 0.15 to 0.5 MPa |
| RO Water Conductivity | 1 to 5 µS/cm |
| DI Water Conductivity | Less than 0.1 µS/cm |
| DI Water Resistivity | 10 to 16 MΩ·cm at 25°C |
| DI Water Total Organic Carbon (TOC) | Less than 30 ppb |
| UP Water Resistivity | 18.25 MΩ·cm at 25°C |
| Inlet Water Temperature | 5 to 40°C |
| UP Water Heavy Metal Ion | Less than 0.01 ppb |
| UP Water TOC | Less than 3 ppb |
| UP Water Bacteria | Less than 1 CFU/ml (with terminal filter) |
| UP Water Particulate Matter | Less than 1/ml (Greater than 0.1 microns) |
| UP Water Pyrogen (Endotoxin) | Less than 0.001 EU/ml |
| UP Water Ribonuclease (RNase) | Less than 1 pg/ml |
| UP Water Deoxyribonucleases (DNase) | Less than 5 pg/ml |
| Main Machine Dimension | 450 × 470 × 550 mm |
| Auxiliary Chassis Dimension | 470 × 500 × 870 mm |
| Main Machine Packaging Dimension | 550 × 630 × 750 mm |
| Auxiliary Chassis Packaging Dimension | 550 × 550 × 960 mm |
| Main Machine Net Weight | 30 kg |
| Auxiliary Chassis Net Weight | 50 kg |
| Main Machine Gross Weight | 40 kg |
| Auxiliary Chassis Gross Weight | 60 kg |
Deionized Water System LDIN-B11 delivers a flow rate of 90 liters per hour, ensuring efficient high-volume water production. It operates with inlet water pressures of 0.15 to 0.5 MPa, adapting to different water supply conditions. The system functions optimally in temperatures between 5 and 40°C, offering flexibility in different environments. Equipped with a KDF device, it removes chlorine and heavy metals, extending consumable life. Ideal for applications requiring ultra-pure water, such as molecular biology, drug development, and cell culture.
Applications:
Our Deionized Water System LDIN-B11 supports applications like ultra-pure water preparation for laboratories, pharmaceuticals, electronics cleaning, chemical analysis, medical devices, and research requiring high water purity.
Optional Accessories:
Review sent
Your review cannot be sent

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase
| Country of Origin | UK |
|---|---|
| Power Consumption | 48 to 72 W |
| Brand | Labtron |
| Power Supply | 100 to 240V / 50/60 Hz |
| Model | LDIN-B11 |
| Tank Capacity | 40 L |
| Type of Product | Water Purification System |
| Water Output Rate | 90 L/hr |
| Inlet Water Pressure | 0.15 to 0.5 MPa |
| RO Water Conductivity | 1 to 5 µS/cm |
| DI Water Conductivity | Less than 0.1 µS/cm |
| DI Water Resistivity | 10 to 16 MΩ·cm at 25°C |
| DI Water Total Organic Carbon (TOC) | Less than 30 ppb |
| UP Water Resistivity | 18.25 MΩ·cm at 25°C |
| Inlet Water Temperature | 5 to 40°C |
| UP Water Heavy Metal Ion | Less than 0.01 ppb |
| UP Water TOC | Less than 3 ppb |
| UP Water Bacteria | Less than 1 CFU/ml (with terminal filter) |
| UP Water Particulate Matter | Less than 1/ml (Greater than 0.1 microns) |
| UP Water Pyrogen (Endotoxin) | Less than 0.001 EU/ml |
| UP Water Ribonuclease (RNase) | Less than 1 pg/ml |
| UP Water Deoxyribonucleases (DNase) | Less than 5 pg/ml |
| Main Machine Dimension | 450 × 470 × 550 mm |
| Auxiliary Chassis Dimension | 470 × 500 × 870 mm |
| Main Machine Packaging Dimension | 550 × 630 × 750 mm |
| Auxiliary Chassis Packaging Dimension | 550 × 550 × 960 mm |
| Main Machine Net Weight | 30 kg |
| Auxiliary Chassis Net Weight | 50 kg |
| Main Machine Gross Weight | 40 kg |
| Auxiliary Chassis Gross Weight | 60 kg |
Deionized Water System LDIN-B11 delivers a flow rate of 90 liters per hour, ensuring efficient high-volume water production. It operates with inlet water pressures of 0.15 to 0.5 MPa, adapting to different water supply conditions. The system functions optimally in temperatures between 5 and 40°C, offering flexibility in different environments. Equipped with a KDF device, it removes chlorine and heavy metals, extending consumable life. Ideal for applications requiring ultra-pure water, such as molecular biology, drug development, and cell culture.
Applications:
Our Deionized Water System LDIN-B11 supports applications like ultra-pure water preparation for laboratories, pharmaceuticals, electronics cleaning, chemical analysis, medical devices, and research requiring high water purity.
Optional Accessories:
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Review sent
Your review cannot be sent
Labtron LDIN-B11 Deionized Water System
Comments (0)
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent