| Measurement Range | 0.1 to 240 mg N |
|---|---|
| Brand | Labtron |
| Power Supply | 220 V AC ± 10% / 50 Hz |
| Power | 2 kW |
| Function | Distillation and titration function based on classic Kjeldahl nitrogen determination method |
| Model | LKA-C11 |
| Reproducibility | Average value relative error ≤ ± 0.5% |
| Analysis Time | 5 to 10 min/sample |
| Weight | 38 Kg |
| Pump | 4 KNF pumps |
| Recovery Rate | ≥ 99.5% |
| Sample | Solid ≤ 5 g/sample / Liquid ≤ 20 mL/sample |
| Dimension (W × D × H) | 455 × 391 × 730 mm |
| Data Storage Capacity | 1000 groups |
| Burette Volume | 2.0 µl/step |
| Condensate Water Consumption | 1.5 L/min |
| Automatic Function | Receiving cup cleaning / alkali pipeline cleaning / boric acid pipeline cleaning / acid washing / and steam bottle evacuation |
Fully-Automatic Kjeldahl Analyzer LKA-C11 is a compact and fully automated unit, equipped with distillation and titration functions based on the classic Kjeldahl nitrogen determination method. It offers a measuring range of 0.1 to 240 mg N with 5 to 10 minutes per sample of analysis time. With a 2.0 µl/step burette volume, 5g of solid sample, and 20 ml of liquid sample capacity, it features pre-installed cleaning functions, including receiving cup cleaning, alkali pipeline cleaning, boric acid pipeline cleaning, acid washing, and steam bottle evacuation. Designed with 4 KNF pumps for dosing and measuring liquid volume, it offers real-time detection of distilled liquid temperature and high titration accuracy. Equipped with an external titration cup, integrated printer, and the latest core control system, it also has data storage capacity for 1000 groups.
Applications:
Fully-Automatic Kjeldahl Analyzer is used for the determination of ammonia nitrogen, protein determination, nitrogen content, nitric nitrogen, phenols, volatile acids, cyanides, alcohol content, etc. across food processing, feed production, tobacco, animal husbandry, soil fertility, environmental monitoring, medicine, agriculture, scientific research, teaching, quality supervision, and more.
Review sent
Your review cannot be sent

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase
| Measurement Range | 0.1 to 240 mg N |
|---|---|
| Brand | Labtron |
| Power Supply | 220 V AC ± 10% / 50 Hz |
| Power | 2 kW |
| Function | Distillation and titration function based on classic Kjeldahl nitrogen determination method |
| Model | LKA-C11 |
| Reproducibility | Average value relative error ≤ ± 0.5% |
| Analysis Time | 5 to 10 min/sample |
| Weight | 38 Kg |
| Pump | 4 KNF pumps |
| Recovery Rate | ≥ 99.5% |
| Sample | Solid ≤ 5 g/sample / Liquid ≤ 20 mL/sample |
| Dimension (W × D × H) | 455 × 391 × 730 mm |
| Data Storage Capacity | 1000 groups |
| Burette Volume | 2.0 µl/step |
| Condensate Water Consumption | 1.5 L/min |
| Automatic Function | Receiving cup cleaning / alkali pipeline cleaning / boric acid pipeline cleaning / acid washing / and steam bottle evacuation |
Fully-Automatic Kjeldahl Analyzer LKA-C11 is a compact and fully automated unit, equipped with distillation and titration functions based on the classic Kjeldahl nitrogen determination method. It offers a measuring range of 0.1 to 240 mg N with 5 to 10 minutes per sample of analysis time. With a 2.0 µl/step burette volume, 5g of solid sample, and 20 ml of liquid sample capacity, it features pre-installed cleaning functions, including receiving cup cleaning, alkali pipeline cleaning, boric acid pipeline cleaning, acid washing, and steam bottle evacuation. Designed with 4 KNF pumps for dosing and measuring liquid volume, it offers real-time detection of distilled liquid temperature and high titration accuracy. Equipped with an external titration cup, integrated printer, and the latest core control system, it also has data storage capacity for 1000 groups.
Applications:
Fully-Automatic Kjeldahl Analyzer is used for the determination of ammonia nitrogen, protein determination, nitrogen content, nitric nitrogen, phenols, volatile acids, cyanides, alcohol content, etc. across food processing, feed production, tobacco, animal husbandry, soil fertility, environmental monitoring, medicine, agriculture, scientific research, teaching, quality supervision, and more.