Single Beam Atomic Absorption Spectrophotometer 190-900nm

₹1
Tax included
Quantity

Specifications

Brand Shamboo scientific
Resolution Min 3 lines (279.5 & 279.8 peak and Valley )
Bandwidth 0.1|0.2|0.4|1nm(4 step auto switching)
Instrument Type Single Beam Reflection Achromatic Optics System
Photometric Range 0-125%| -0.1-3.00A
Detection limit (Cu) 0.004 g/ml max
Safety measures Flame fuel gas| power assisted gas abnormal pressure protection Gas Leak check| prevention of gas release when flame dies out| prevention of flashback through pressure monitoring.
Working Temperature range 10~300C
Concentration standard curve| standard addition| interpolation
Spray Chamber Anticorrosion material
Gas Control Automatic control & optimization flow/pressure)
Monochromator Aberration Corrected Czerny-Turner
Dispersion elements Grating system 1200 line/mm characterization area 40mm 2 Scintillation wavelength 250nm
WL Range 190-900
WL Accuracy 0.2
WL Repeatability 0.1 nm max
HCL housing Standard 4 lamp turret .( 1for measurement | 3 in warm-up mode) Option -6 Lamp / 8 Lamp Turret .
Static Baseline Drift (Cu) +-0.003A/30min
Dynamic BaselineDrif (Cu) +-0.006A/30min
BACKGROUND CORRECTION High speed self-reversal (BGC-SR) method High speed D2 lamp method (BGC-D2)
Characteristic Concentration (Cu) 0.025 g/ml max
Burner Air cooled Titanium
Times of repetitive Measurement 1-30 times| Average Value of A&C
Dimension & Weight (Flame) 700420550 mm| 103 kg(approx.)
Power (Main unit with(Flame) AC 220 V 10%| 50 Hz without sharp fluctuations.
Working Humidity range 40%~85%

Key Features

  • Advance technology for intelligent stray light measure and correction Original Optical Noise Reduction & Automatic measurement and stray light dynamic detected without any reference materials and incremental cost. It improves instruments optical performance, optical precision, linear range and background correction effectively
  • Develop internal lamp control technology. It makes normal hallow cathode lamps self-absorption background correction possible without and in?uence to instrument's stability. Meanwhile it will prolong working life of the lamps. Normal hallow cathode lamps are highly economical than special lamps
Reference AAFSL Category Atomic Absorption Spectroscopy

Product Details

We present a wide range of Quality Equipment required in day-to-dayfunction of aChemical Laboratory to Advanced Instruments used for QualityAssurance/Control and Research.Our Atomic Absorption Spectrophotometer offers a State-of-the-arttechnology bundled with manyfeatures as a complete economical
  • Original''Hg lamp-regent'' gradient measurement. we established an exact mathematical model. to estimate single beam linear and balancespeci?cation. This technology provided a fast and economic method for instrument self testing system. It also established a brand new method to improve instrument's detection Performance.
  • Original''Hg lamp-regent'' gradient measurement. we established an exact mathematical model to estimate single beam linear and balancespeci?cation. This technology provided a fast and economic method for instrument self testing system. It also established a brand new method to improve instrument's detection Performance

Other Products from this Brand