$69.50
Tax included
×
Product Enquiry
Labtron LGC-B14 Gas Chromatography System
World's First Climate Tech Platform | Free Delivery in India | Global Shipping

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase
| Brand | Labtron |
|---|---|
| Power Supply | AC220V ±10% / 50Hz |
| Memory | 20 sample test modes |
| Model | LGC-B14 |
| Amplifier | Logarithmic amplifier |
| Gross Weight | 80 Kg |
| Detector Type | Hydrogen Flame Ionization Detector (FID) |
| Detection limit | ≤ 3 × 10⁻¹² g/s (Sample - n-hexadecane) |
| Heating Temperature | 60 °C/min |
| Display function | Baseline signal display |
| Oven Temperature Range | RT + 5 °C to 400 °C |
| Dynamic Range | 10⁷ |
| Packaging Dimension (W × D × H) | 735 × 725 × 835 mm |
| Oven Temperature accuracy | ± 0.1 °C |
| Sample Injector Temperature range | RT + 7°C to 420 °C |
| Temperature Program | 9 Step |
| Program Timing | 9999.9 min |
| Sample Injector Max. Quantity | 3 pieces |
| Pre-Column Pressure Range | 0 to 400 kPa |
| Pre-Column Pressure Accuracy | 0.1 kPa |
| Flow Setting Range | H₂ - 0-200 ml/min / N₂ - 0-150 ml/min |
| Detector Temp. Range | RT + 7°C to 420°C |
| Switch Control Function | High voltage switch control |
| Baseline Noise | ≤ 5 × 10⁻¹⁴ A |
| Baseline Draft | ≤ 6 × 10⁻¹³ A |
| RSD | ≤ 3 % |
| Oven Capacity | 22L |
Gas Chromatography System LGC-B14 offers a 22L oven capacity and an adjustable temperature range from RT + 5°C to 400°C. It is equipped with a 7-inch LCD for real-time monitoring of temperature, gas flow, and heating curves. Its advanced self-test function and automatic fault detection ensure reliable and efficient performance. This system also includes a highly sensitive flame ionization detector (FID) for accurate detection of organic compounds.
Applications:
Our Gas Chromatography System is widely used for the separation and analysis of complex mixtures in chemical, pharmaceutical, and environmental testing. It enables precise detection of volatile organic compounds in samples, making it essential for quality control and research applications.
Standard Accessories:
Review sent
Your review cannot be sent

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase
| Brand | Labtron |
|---|---|
| Power Supply | AC220V ±10% / 50Hz |
| Memory | 20 sample test modes |
| Model | LGC-B14 |
| Amplifier | Logarithmic amplifier |
| Gross Weight | 80 Kg |
| Detector Type | Hydrogen Flame Ionization Detector (FID) |
| Detection limit | ≤ 3 × 10⁻¹² g/s (Sample - n-hexadecane) |
| Heating Temperature | 60 °C/min |
| Display function | Baseline signal display |
| Oven Temperature Range | RT + 5 °C to 400 °C |
| Dynamic Range | 10⁷ |
| Packaging Dimension (W × D × H) | 735 × 725 × 835 mm |
| Oven Temperature accuracy | ± 0.1 °C |
| Sample Injector Temperature range | RT + 7°C to 420 °C |
| Temperature Program | 9 Step |
| Program Timing | 9999.9 min |
| Sample Injector Max. Quantity | 3 pieces |
| Pre-Column Pressure Range | 0 to 400 kPa |
| Pre-Column Pressure Accuracy | 0.1 kPa |
| Flow Setting Range | H₂ - 0-200 ml/min / N₂ - 0-150 ml/min |
| Detector Temp. Range | RT + 7°C to 420°C |
| Switch Control Function | High voltage switch control |
| Baseline Noise | ≤ 5 × 10⁻¹⁴ A |
| Baseline Draft | ≤ 6 × 10⁻¹³ A |
| RSD | ≤ 3 % |
| Oven Capacity | 22L |
Gas Chromatography System LGC-B14 offers a 22L oven capacity and an adjustable temperature range from RT + 5°C to 400°C. It is equipped with a 7-inch LCD for real-time monitoring of temperature, gas flow, and heating curves. Its advanced self-test function and automatic fault detection ensure reliable and efficient performance. This system also includes a highly sensitive flame ionization detector (FID) for accurate detection of organic compounds.
Applications:
Our Gas Chromatography System is widely used for the separation and analysis of complex mixtures in chemical, pharmaceutical, and environmental testing. It enables precise detection of volatile organic compounds in samples, making it essential for quality control and research applications.
Standard Accessories:
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Review sent
Your review cannot be sent
Labtron LGC-B14 Gas Chromatography System
Comments (0)
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent