Previous
Next
Share
Free Delivery in India | Lowest Global Shipping Charges
24/7 Customer Support
24/7 Customer Support

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

24/7 Customer Support
Save up to 28% with GST Input

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

Lowest Price Challenge
# Lowest Price Challenge

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Lowest Price Challenge
100% Original Products

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase

Gas Chromatography EGC-B13

SKU ADBRF Category Gas Chromatography Brand Generic Brand Condition New

Specifications

Resolution 0.001 psi
Temperature Accuracy ± 0.1 °C
Brand Generic Brand
Power Supply 220V±10%
Dimension 65 × 48 × 55 cm
Model LGC-B13
Weight 50 Kg
Temperature Control 200 °C
Temperature Control Range Room Temperature to 450 °C
Display function Fault Information / Power Failure Storage Protection / Keyboard Lock / Anti-Power Supply
Communication Interface Ethernet / IEEE802.3
Atmospheric pressure 0 to 1035 kPa (0 to 150 psi)
Capillary Columns 2 × 80m
Gas Types He / N₂ / H₂ / Ar
Injection Pressure Less than10Mpa
Temperature Increments 1 °C
Temperature Program 16 level
Temperature Rise Rate 0.1 to 80 °C/min
Programmable Cooling 450 °C to 50 °C
Network Interface RJ45
Hydrogen Flame Detector Mt ≤ 3×10⁻¹² g/s (N-hexadecane)
Injection Systems Filled Column / Capillary Split/Non-Split
Internet Connectivity Long-Distance Data Transmission / Remote Control / Remote Diagnosis / Automated Program Upgrades
Main Frame Size 510 × 500 × 540 mm
Column Oven Volume 300 × 280 × 170 mm³

Key Features

  • Integrates Internet communication technology
  • Utilizes a new integrated digital electronic circuit
  • Equipped with advanced flow controller carrier and autosampler
  • Innovative inlet port design resolves inlet discrimination issues
  • Double column compensation function mitigates background noise effects
  • Incorporates a unique vapor chamber design with a smaller dead volume
  • The back door system enables step-less variable control of inlet and outlet air volume
  • Equipped with a robust power-on self-diagnostic function

Product Description

Gas Chromatography LGC-B13 is equipped with a spacious column oven measuring 300 × 280 × 170 mm³, allowing the simultaneous accommodation of two 80m capillary columns. It features comprehensive microcomputerized key operation with a 5.7-inch 13-line LCD display, ensuring user-friendly interactions. The network anti-control capabilities enable multifaceted network control, including network remote control. Additionally, it provides anti-control features for temperature, pressure, data, and bridge current, ensuring precision and protection against unauthorized manipulation.

Applications:

Ideal for analyzing trace toxic compounds, conducting environmental monitoring and research, and is extensively utilized in petrochemistry, environmental protection, epidemic prevention, pharmacology, and scientific research.

Standard Accessories:

  • • FID Detector: Mt <1×10⁻¹²g/s (n-Hexadecane), Sensitivity drifting <0.2mv/h, Linearity >10⁶.
  • • TCD Detector: S > 10000mv.ml/mg (N-hexadecane), Sensitivity drifting <20uv, Linearity >10⁴.
  • • ECD Detector: Mt < 1 ×10⁻¹³g/ml (r-666), Sensitivity drifting <15uv, Linearity >10⁶.
  • • FPD Detector: Mt < 2×10⁻¹¹g/s (S in thiophene), Mt < 1×10⁻¹¹g/s (P in methyl parathion), Sensitivity drifting 3% of full scale, Linearity >10³.

Optional Accessories:

  • • Automatic/Manual Gas Six-Way Injection Valve Injector
  • • Headspace Injector
  • • Thermal Analysis Injector
  • • Cracking Furnace Injector
  • • Methane Conversion Furnace
Gas Chromatography EGC-B13
Looking to purchase in bulk?
  • Purchase item in bulk quantity
  • Get best price for your business

Comments (0)

No customer reviews for the moment.

Frequently Asked Questions

The temperature control range of this model is from Room Temperature to 450 °C.

This unit has dimensions of 65 × 48 × 55 cm and weighs 50 Kg.

It is compatible with helium (He), nitrogen (N₂), hydrogen (H₂), and argon (Ar) as carrier gases.

The maximum injection pressure for this gas chromatography system is less than 10 Mpa.

It can accommodate two 80m capillary columns simultaneously.

The resolution capability is 0.001 psi.

This unit features Ethernet and IEEE802.3 communication interfaces.

The temperature accuracy of this model is ± 0.1 °C.

The temperature rise rate can be set between 0.1 to 80 °C/min.

It can cool from 450 °C to 50 °C programmably.

It incorporates internet connectivity for long-distance data transmission, remote control, remote diagnosis, and automated program upgrades.

Related Products

Recently Viewed Products

$69.50
Tax included
Quantity
Delivery Time Delivered within 0-3 days
  • Global Payments 140+ CountriesGlobal Payments 140+ Countries
  • Global Shipping Fedex/UPS/DHL/Aramex/
BlueDart/Delhivery/DP WorldGlobal Shipping Fedex/UPS/DHL/Aramex/ BlueDart/Delhivery/DP World
  • 24/7 Customer Support Email/Chat/Telephonic Support24/7 Customer Support Email/Chat/Telephonic Support
$69.50
Tax included