Previous
Next
Share
Free Delivery in India | Lowest Global Shipping Charges
24/7 Customer Support
24/7 Customer Support

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

24/7 Customer Support
Save up to 28% with GST Input

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

Lowest Price Challenge
# Lowest Price Challenge

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Lowest Price Challenge
100% Original Products

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase

Labtron LGC-B12 Gas Chromatography

SKU ADBRE Category Gas Chromatography Brand Labtron

Specifications

Brand Labtron
Power Supply AC 110/220 V±10% / 50/60 Hz
Model LGC-B12
Gross Weight 71 kg
Oven Temperature Range RT to 450ºC
Packaging Dimension (W×D×H) 820×670×600 mm
Oven Temperature accuracy ≤±0.1ºC
Oven Temperature program 16-phase
Sample Injector Temperature range RT + 7 ºC to 420 ºC
Sample Injector Temperature control Automatic
Sample Injector Injector type Column or split
Sample Injector Maximum sample inlet 3 pcs
Sample Injector Carrier gas flow type Constant pressure
Sample Injector Mobile phase flow range H2 - 0 to 200 ml/min / N2 - 0 to 150 ml/min
Oven Maximum Temperature Heating Rate 40ºC/min
Sample Injector Pre Column Pressure Range 0 to 400 kPa
Sample Injector Pre Column Pressure Accuracy 0.1 kPa
FID Detector Temperature Range RT + 7 ºC to 420 ºC
FID Detector Maximum Installation Dual detector
FID Detector Flame Ignition Mode Automatic
FID Detector Flame Ionization Detector (FID) Logarithmic amplifier / Mechanical valve / Baseline signal display / Ignition coil control
FID Detector Detection Limit ≤3×10⁻¹² g/s (Sample - n-hexadecane)
FID Detector Baseline Drift ≤1×10⁻¹³ A/30 min
FID Detector Linear Range ≥10⁷

Key Features

  • A compact and tabletop Flame Ionization Detector (FID) comprised gas chromatography
  • RT to 450°C of temperature range and 40°C / min of maximum heating rate with 16-phase temperature program
  • TCD, ECD, FPD, and NPD as optional detectors, with 3 detectors installation at a time
  • Packed column and capillary column installation at the same time
  • Large oven capacity to hold 2 capillary columns of 0.32 mm diameter
  • Thermal insulation, maximum outer chamber temperature of 40℃
  • Chromatography workstation software, for easy and convenient data processing
  • Supports self-test, power protection, keyboard lock, automatic ignition, and anti-power mutation interference function
  • 5.7-inch LCD display, for convenient indication of temperature, time, and gas flow
  • Double column compensation function for effective restraining of baseline drift and the influence of background noise
  • Internet connection for easy data transferring and program update
  • Highly efficient, stable, and reliable with easy and convenient operation

Product Description

Gas Chromatography LGC-B12 is a compact tabletop Flame Ionization Detector (FID)-based gas chromatograph, offering a temperature range from RT to 450°C with a maximum heating rate of 40°C/min. It supports up to three detectors installed simultaneously, including optional TCD, ECD, FPD, and NPD detectors. It allows packed column and capillary column installation at the same time. The large oven capacity holds two capillary columns of 0.32 mm diameter. Equipped with thermal insulation, chromatography workstation software, and a 5.7-inch LCD display, it supports self-test, power protection, keyboard lock, automatic ignition, and anti-power mutation interference functions. The double column compensation function and internet connectivity enhance usability. This GC system supports 16-phase temperature programming, effectively restraining baseline drift and reducing background noise interference.

Applications:

Used for the separation of compounds in complex mixtures based on polarity across industries such as food, pharmaceuticals, dairy, microbiology, biotechnology, and environmental analysis.

Standard Accessories:

  • FID detector × 1
  • chromatography workstation software × 1

Optional Accessories:

  • Hydrogen generator × 1
  • air generator × 1
  • Thermal Conductivity Detector (TCD) (Sensitivity: >10000 mv.ml/mg, Sample: n-hexadecane, Linear range: ≥10⁵) × 1
  • Electron Capture Detector (ECD) (Detection limit: ≤1×10⁻¹⁴ g/ml, Sample: n-hexadecane δ-666, Linear range: ≥10³) × 1
  • Flame Photometric Detector (FPD) (Detection limit: ≤2×10⁻¹¹g/s (S of thiophene), ≤1×10⁻¹²g/s (P of methyl parathion), Linear range (S): ≥10², Linear range (P): ≥10³) × 1
  • Nitrogen and Phosphorus Detector (NPD) (Detection limit: ≤1×10⁻¹²g/s (Azobenzene), ≤1×10⁻¹²g/s (Marla sulfur phosphorous), Linear range: ≥10³) × 1

Comments (0)

Related Products

$69.50
Tax included
Quantity
Delivery Time Delivered within 0-3 days
  • Genuine Products   
  • Global Shipping 
  • Secured Payments
Previous
Next
Share
Free Delivery in India | Lowest Global Shipping Charges
24/7 Customer Support
24/7 Customer Support

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

24/7 Customer Support
Save up to 28% with GST Input

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

Lowest Price Challenge
# Lowest Price Challenge

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Lowest Price Challenge
100% Original Products

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase

Labtron LGC-B12 Gas Chromatography

SKU ADBRE Category Gas Chromatography Brand Labtron

Specifications

Brand Labtron
Power Supply AC 110/220 V±10% / 50/60 Hz
Model LGC-B12
Gross Weight 71 kg
Oven Temperature Range RT to 450ºC
Packaging Dimension (W×D×H) 820×670×600 mm
Oven Temperature accuracy ≤±0.1ºC
Oven Temperature program 16-phase
Sample Injector Temperature range RT + 7 ºC to 420 ºC
Sample Injector Temperature control Automatic
Sample Injector Injector type Column or split
Sample Injector Maximum sample inlet 3 pcs
Sample Injector Carrier gas flow type Constant pressure
Sample Injector Mobile phase flow range H2 - 0 to 200 ml/min / N2 - 0 to 150 ml/min
Oven Maximum Temperature Heating Rate 40ºC/min
Sample Injector Pre Column Pressure Range 0 to 400 kPa
Sample Injector Pre Column Pressure Accuracy 0.1 kPa
FID Detector Temperature Range RT + 7 ºC to 420 ºC
FID Detector Maximum Installation Dual detector
FID Detector Flame Ignition Mode Automatic
FID Detector Flame Ionization Detector (FID) Logarithmic amplifier / Mechanical valve / Baseline signal display / Ignition coil control
FID Detector Detection Limit ≤3×10⁻¹² g/s (Sample - n-hexadecane)
FID Detector Baseline Drift ≤1×10⁻¹³ A/30 min
FID Detector Linear Range ≥10⁷

Key Features

  • A compact and tabletop Flame Ionization Detector (FID) comprised gas chromatography
  • RT to 450°C of temperature range and 40°C / min of maximum heating rate with 16-phase temperature program
  • TCD, ECD, FPD, and NPD as optional detectors, with 3 detectors installation at a time
  • Packed column and capillary column installation at the same time
  • Large oven capacity to hold 2 capillary columns of 0.32 mm diameter
  • Thermal insulation, maximum outer chamber temperature of 40℃
  • Chromatography workstation software, for easy and convenient data processing
  • Supports self-test, power protection, keyboard lock, automatic ignition, and anti-power mutation interference function
  • 5.7-inch LCD display, for convenient indication of temperature, time, and gas flow
  • Double column compensation function for effective restraining of baseline drift and the influence of background noise
  • Internet connection for easy data transferring and program update
  • Highly efficient, stable, and reliable with easy and convenient operation

Product Description

Gas Chromatography LGC-B12 is a compact tabletop Flame Ionization Detector (FID)-based gas chromatograph, offering a temperature range from RT to 450°C with a maximum heating rate of 40°C/min. It supports up to three detectors installed simultaneously, including optional TCD, ECD, FPD, and NPD detectors. It allows packed column and capillary column installation at the same time. The large oven capacity holds two capillary columns of 0.32 mm diameter. Equipped with thermal insulation, chromatography workstation software, and a 5.7-inch LCD display, it supports self-test, power protection, keyboard lock, automatic ignition, and anti-power mutation interference functions. The double column compensation function and internet connectivity enhance usability. This GC system supports 16-phase temperature programming, effectively restraining baseline drift and reducing background noise interference.

Applications:

Used for the separation of compounds in complex mixtures based on polarity across industries such as food, pharmaceuticals, dairy, microbiology, biotechnology, and environmental analysis.

Standard Accessories:

  • FID detector × 1
  • chromatography workstation software × 1

Optional Accessories:

  • Hydrogen generator × 1
  • air generator × 1
  • Thermal Conductivity Detector (TCD) (Sensitivity: >10000 mv.ml/mg, Sample: n-hexadecane, Linear range: ≥10⁵) × 1
  • Electron Capture Detector (ECD) (Detection limit: ≤1×10⁻¹⁴ g/ml, Sample: n-hexadecane δ-666, Linear range: ≥10³) × 1
  • Flame Photometric Detector (FPD) (Detection limit: ≤2×10⁻¹¹g/s (S of thiophene), ≤1×10⁻¹²g/s (P of methyl parathion), Linear range (S): ≥10², Linear range (P): ≥10³) × 1
  • Nitrogen and Phosphorus Detector (NPD) (Detection limit: ≤1×10⁻¹²g/s (Azobenzene), ≤1×10⁻¹²g/s (Marla sulfur phosphorous), Linear range: ≥10³) × 1

Comments (0)

$69.50
Tax included
Quantity
Delivery Time Delivered within 0-3 days
  • Genuine Products   
  • Global Shipping 
  • Secured Payments
$69.50
Tax included