Previous
Next
Share
Free Delivery in India | Lowest Global Shipping Charges
24/7 Customer Support
24/7 Customer Support

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

24/7 Customer Support
Save up to 28% with GST Input

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

Lowest Price Challenge
# Lowest Price Challenge

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Lowest Price Challenge
100% Original Products

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase

Labtron LGC-B11 Gas Chromatography

SKU ADBRD Category Gas Chromatography Brand Labtron

Specifications

Brand Labtron
Model LGC-B11
Detector Type FID or TCD
Oven Temperature Range RT + 5 °C to 400 °C
Oven Temperature accuracy ± 0.1 °C
Oven Temperature program 9 Step
Oven Program total time 9999.9 min
Oven Maximum Heating Rate 0.1 to 60 °C/min
Oven Maximum Cooling Rate ≤ 10 mins (250 to 50 °C)
Sample Injector Temperature range RT + 7 °C to 420 °C
Sample Injector Temperature control Independent
Sample Injector Injector type Column or split
Sample Injector Maximum sample inlet 3 pcs
Sample Injector Carrier gas flow type Constant pressure
Sample Injector Pressure range 0 to 400 kPa
Sample Injector Pressure accuracy 0.1 kPa
Sample Injector Mobile phase flow range H2 - 0 to 200 ml/min / N2 - 0 to 150 ml/min
Detector Temperature range RT + 7 °C to 420 °C
Detector Maximum installation Dual detector
Detector Flame ignition mode Automatic
FID Logarithmic amplifier Yes
FID High voltage switch control Yes
FID Baseline signal display Yes
FID Ignition coil control Yes
FID Detection limit ≤ 3 × 10⁻¹² g/s (Sample - n-hexadecane)
FID Baseline noise ≤ 5 × 10⁻¹⁴ A
FID Baseline draft ≤ 6 × 10⁻¹³
FID Dynamic range 10⁷
FID RSD ≤ 3 %
TCD Sensitivity 8000mV.ml/mg (Sample - n-hexadecane)
TCD Baseline noise ≤ 0.5mV
TCD Baseline draft ≤ 0.15 mV/30 min
General Power supply AC 220 V ± 22 V / 50 Hz ± 0.5 Hz / 3000 W
General Packing dimension 1020 × 660 × 740 mm
General Gross Weight 82 kg
General Net Weight 70 kg
Oven Maximum Capacity 22 L

Key Features

  • 7-inch LCD display specifies temperature, gas flow, and heating curve
  • H2 and N2 mobile gas phase with AFC and constant pressure gas flow type
  • Equipped with capillary analysis system and capillary split sampler
  • Injection system incorporates diaphragm cleaning, split flow, and auxiliary gas adjustment
  • Standard unit for high-speed analysis with polar capillary column
  • PEG-20M and FFAP stationary phase polar capillary columns can be coupled
  • Dual FID detector with automatic flame ignition and baseline signal display
  • Self-diagnostic and automatic fault recognition function
  • Multi-core and 32-bit embedded hardware system ensures reliable operation
  • Equipped with chromatography workstation software to process data
  • Memory function can store 20 sample test data
  • RS232 interface and LAN port

Product Description

Gas Chromatography LGC-B11 is a benchtop unit with advanced flow controller (AFC) technology. The system features digital control mode and polar capillary columns to separate polar analytes. The GC oven is capable of 9 temperature program ramps and hold steps and offers rapid cooling from 250°C to 50°C in less than 10 minutes. Accurate flow rate control via AFC ensures higher repeatability of retention time and peak area, enabling specific levels of analysis using dual FID detectors.

Applications:

Suitable for the analysis of trace toxic compounds, monitoring, and research in environmental protection, atmosphere, and water source pollution. It is widely used in petrochemistry, environmental protection, epidemic prevention, pharmacology, and scientific research.

Standard Accessories:

  • FID detector system × 1
  • capillary injection system × 1
  • chromatography workstation software × 1

Optional Accessories:

  • Polar capillary columns PEG-20M (Stationary phase: 30 m × 0.32 mm, Injector temperature: 250°C, Oven temperature: 165°C, Detector: FID-250°C, Inlet pressure: 0.04 MPa) × 1
  • polar capillary columns FFAP (Stationary phase: 30 m × 0.32 mm, Injector temperature: 250°C, Oven temperature: 165°C, Detector: FID-250°C, Inlet pressure: 0.04 MPa) × 1
  • syringe 1 μL × 1
  • syringe 5 μL × 1

Comments (0)

Related Products

$69.50
Tax included
Quantity
Delivery Time Delivered within 0-3 days
  • Genuine Products   
  • Global Shipping 
  • Secured Payments
Previous
Next
Share
Free Delivery in India | Lowest Global Shipping Charges
24/7 Customer Support
24/7 Customer Support

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

24/7 Customer Support
Save up to 28% with GST Input

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

Lowest Price Challenge
# Lowest Price Challenge

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Lowest Price Challenge
100% Original Products

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase

Labtron LGC-B11 Gas Chromatography

SKU ADBRD Category Gas Chromatography Brand Labtron

Specifications

Brand Labtron
Model LGC-B11
Detector Type FID or TCD
Oven Temperature Range RT + 5 °C to 400 °C
Oven Temperature accuracy ± 0.1 °C
Oven Temperature program 9 Step
Oven Program total time 9999.9 min
Oven Maximum Heating Rate 0.1 to 60 °C/min
Oven Maximum Cooling Rate ≤ 10 mins (250 to 50 °C)
Sample Injector Temperature range RT + 7 °C to 420 °C
Sample Injector Temperature control Independent
Sample Injector Injector type Column or split
Sample Injector Maximum sample inlet 3 pcs
Sample Injector Carrier gas flow type Constant pressure
Sample Injector Pressure range 0 to 400 kPa
Sample Injector Pressure accuracy 0.1 kPa
Sample Injector Mobile phase flow range H2 - 0 to 200 ml/min / N2 - 0 to 150 ml/min
Detector Temperature range RT + 7 °C to 420 °C
Detector Maximum installation Dual detector
Detector Flame ignition mode Automatic
FID Logarithmic amplifier Yes
FID High voltage switch control Yes
FID Baseline signal display Yes
FID Ignition coil control Yes
FID Detection limit ≤ 3 × 10⁻¹² g/s (Sample - n-hexadecane)
FID Baseline noise ≤ 5 × 10⁻¹⁴ A
FID Baseline draft ≤ 6 × 10⁻¹³
FID Dynamic range 10⁷
FID RSD ≤ 3 %
TCD Sensitivity 8000mV.ml/mg (Sample - n-hexadecane)
TCD Baseline noise ≤ 0.5mV
TCD Baseline draft ≤ 0.15 mV/30 min
General Power supply AC 220 V ± 22 V / 50 Hz ± 0.5 Hz / 3000 W
General Packing dimension 1020 × 660 × 740 mm
General Gross Weight 82 kg
General Net Weight 70 kg
Oven Maximum Capacity 22 L

Key Features

  • 7-inch LCD display specifies temperature, gas flow, and heating curve
  • H2 and N2 mobile gas phase with AFC and constant pressure gas flow type
  • Equipped with capillary analysis system and capillary split sampler
  • Injection system incorporates diaphragm cleaning, split flow, and auxiliary gas adjustment
  • Standard unit for high-speed analysis with polar capillary column
  • PEG-20M and FFAP stationary phase polar capillary columns can be coupled
  • Dual FID detector with automatic flame ignition and baseline signal display
  • Self-diagnostic and automatic fault recognition function
  • Multi-core and 32-bit embedded hardware system ensures reliable operation
  • Equipped with chromatography workstation software to process data
  • Memory function can store 20 sample test data
  • RS232 interface and LAN port

Product Description

Gas Chromatography LGC-B11 is a benchtop unit with advanced flow controller (AFC) technology. The system features digital control mode and polar capillary columns to separate polar analytes. The GC oven is capable of 9 temperature program ramps and hold steps and offers rapid cooling from 250°C to 50°C in less than 10 minutes. Accurate flow rate control via AFC ensures higher repeatability of retention time and peak area, enabling specific levels of analysis using dual FID detectors.

Applications:

Suitable for the analysis of trace toxic compounds, monitoring, and research in environmental protection, atmosphere, and water source pollution. It is widely used in petrochemistry, environmental protection, epidemic prevention, pharmacology, and scientific research.

Standard Accessories:

  • FID detector system × 1
  • capillary injection system × 1
  • chromatography workstation software × 1

Optional Accessories:

  • Polar capillary columns PEG-20M (Stationary phase: 30 m × 0.32 mm, Injector temperature: 250°C, Oven temperature: 165°C, Detector: FID-250°C, Inlet pressure: 0.04 MPa) × 1
  • polar capillary columns FFAP (Stationary phase: 30 m × 0.32 mm, Injector temperature: 250°C, Oven temperature: 165°C, Detector: FID-250°C, Inlet pressure: 0.04 MPa) × 1
  • syringe 1 μL × 1
  • syringe 5 μL × 1

Comments (0)

$69.50
Tax included
Quantity
Delivery Time Delivered within 0-3 days
  • Genuine Products   
  • Global Shipping 
  • Secured Payments
$69.50
Tax included