Eaton 440V AC Undervoltage Release Circuit Trip for use with N(S)2(-4), N(S)3(-4), NZM2(-4), NZM3(-4) Series NZM2

Category Circuit Trip Brand Eaton Condition New

Specifications

Country of Origin Germany
Range Xboard
Brand Eaton
Model NZM2
Series NZM2/3
Contact Configuration 2 Make
Sub Type Undervoltage Release
Standards/Approvals IEC, CSA, CE, UL 489, UL, IEC 60947
Control Voltage 440V ac

Key Features

  • Compatible with multiple MCCB series for versatile applications.
  • Operates at 440V AC control voltage for reliable circuit protection.
  • Features 2 Make contact configuration for secure switching.
  • Meets high industry standards including IEC, CSA, CE, UL 489, and IEC 60947.
  • Manufactured in Germany ensuring quality and durability.
  • Sub-type undervoltage release prevents improper circuit closing.
  • Suitable for industrial and electrical automation applications.

Product Description

Eaton NZM2 undervoltage release circuit trip is engineered for integration with N(S)2(-4), N(S)3(-4), NZM2(-4), and NZM3(-4) series molded case circuit breakers (MCCBs). This device operates with a control voltage of 440V AC, providing critical protection by releasing the circuit breaker under undervoltage conditions to prevent electrical faults.

The circuit trip features a 2 Make contact configuration, enhancing reliable switching performance in varying electrical environments. Compliance with multiple international standards including IEC, CSA, CE, UL 489, and IEC 60947 ensures adherence to rigorous quality and safety benchmarks.

Designed and manufactured in Germany, this undervoltage release is suitable for use in industrial electrical systems, automation setups, and manufacturing facilities requiring reliable and precise circuit interruption mechanisms.

Its role is vital in protecting electrical circuits by preventing circuit breaker engagement during insufficient voltage conditions, thus safeguarding connected equipment from damage.

Compatible with multiple MCCB series for versatile applications. Operates at 440V AC control voltage for reliable circuit protection. Features 2 Make contact configuration for secure switching. Meets high industry standards including IEC, CSA, CE, UL 489, and IEC 60947.

Manufactured in Germany ensuring quality and durability. Sub-type undervoltage release prevents improper circuit closing. Suitable for industrial and electrical automation applications.

This Eaton undervoltage release circuit trip is a dependable solution for electrical protection needs and is part of a broad range of Circuit Trips and breaker accessories available through EnvMart.

Eaton 440V AC Undervoltage Release Circuit Trip for use with N(S)2(-4), N(S)3(-4), NZM2(-4), NZM3(-4) Series NZM2
Looking to purchase in bulk?
  • Purchase item in bulk quantity
  • Get best price for your business

Comments (0)

No customer reviews for the moment.

Frequently Asked Questions

This model operates at a control voltage of 440V AC.

It is engineered for integration with N(S)2(-4), N(S)3(-4), NZM2(-4), and NZM3(-4) series MCCBs.

The circuit trip features a 2 Make contact configuration for secure switching performance.

It complies with multiple international standards including IEC, CSA, CE, UL 489, and IEC 60947.

This unit is manufactured in Germany.

The sub-type of this unit is an undervoltage release, which prevents improper circuit closing under low voltage conditions.

It is suitable for use in industrial electrical systems, automation setups, and manufacturing facilities.

This model is part of the Xboard range.

The undervoltage release feature is vital for protecting electrical circuits by preventing circuit breaker engagement during insufficient voltage conditions.

The model number of this unit is NZM2.

Its role is to provide critical protection by releasing the circuit breaker under undervoltage conditions to prevent electrical faults.

Key features include a 440V AC control voltage, 2 Make contact configuration, and compliance with high industry standards.

Related Products

Other Products from this brand

$272.40
$264.23 Save 3%
Tax included
Quantity
Delivery Time Delivered within 0-3 days
  • Global Payments 140+ CountriesGlobal Payments 140+ Countries
  • Global Shipping Fedex/UPS/DHL/Aramex/
BlueDart/Delhivery/DP WorldGlobal Shipping Fedex/UPS/DHL/Aramex/ BlueDart/Delhivery/DP World
  • 24/7 Customer Support Email/Chat/Telephonic Support24/7 Customer Support Email/Chat/Telephonic Support
$272.40
$264.23
Tax included