Schneider Electric EMI Filter Motor Choke for Use with Lexium 05, Altivar 61, Altivar 32 Series VW3A4552

Category Motor Accessories Brand Schneider Electric Condition New

Specifications

Country of Origin Czech Republic
Brand Schneider Electric
Model VW3A4552
Series Altivar
Accessory Type Choke

Key Features

  • This choke limits current harmonics produced by the drive effectively.
  • Complies with EN 50178 (VDE 0160 level 1) for high energy overvoltage protection.
  • Designed to maintain inductance values for voltage drop between 3% and 5% of nominal line voltage.
  • Compatible with various Altivar series including Altivar 31C, 312 Solar, 312, 12, and 71.
  • Manufactured in Czech Republic ensuring quality and reliability.
  • Provides enhanced protection and improved drive performance in industrial motor setups.

Product Description

Schneider Electric VW3A4552 EMI Filter Motor Choke is an industrial-grade line choke designed for use with Lexium 05, Altivar 61, Altivar 32, and other Altivar series drives. It enhances system reliability by providing improved protection against line supply overvoltages and reducing harmonic currents generated by motor drives.

This choke is engineered in accordance with the EN 50178 standard (VDE 0160 level 1), ensuring robust protection against high energy overvoltages. It functions by limiting line current harmonics and maintaining inductance values optimized for a voltage drop between 3% and 5% of the nominal line voltage, thereby preserving motor torque and performance.

The VW3A4552 model supports a broad spectrum of Altivar series including Altivar 31C, 312 Solar, 312, 12, and 71, making it versatile for multiple applications in automation and control environments.

Manufactured in the Czech Republic, this EMI filter choke exemplifies Schneider Electric's commitment to quality and industrial-standard engineering. It is ideal for industrial, manufacturing, automation, and HVAC motor control systems where minimizing electrical disturbances and enhancing protection is critical.

This choke limits current harmonics produced by the drive effectively. Complies with EN 50178 (VDE 0160 level 1) for high energy overvoltage protection. Maintains inductance values for voltage drops between 3% and 5% of nominal line voltage.

Compatible with a range of Altivar series motor drives. Manufactured in Czech Republic ensuring high-quality standards. Improves drive performance and system longevity in industrial applications. Explore the comprehensive range of Motor Accessories and EMI filters at EnvMart for reliable and efficient motor control solutions.

Schneider Electric EMI Filter Motor Choke for Use with Lexium 05, Altivar 61, Altivar 32 Series VW3A4552
Looking to purchase in bulk?
  • Purchase item in bulk quantity
  • Get best price for your business

Comments (0)

No customer reviews for the moment.

Frequently Asked Questions

This choke limits current harmonics produced by the drive and enhances protection against line supply overvoltages, thereby improving drive performance in industrial motor setups.

It is compatible with various Altivar series including Altivar 31C, 312 Solar, 312, 12, and 71.

The choke maintains inductance values for voltage drops between 3% and 5% of the nominal line voltage.

It complies with EN 50178 (VDE 0160 level 1) for high energy overvoltage protection.

This model is manufactured in the Czech Republic, ensuring quality and reliability.

It is classified as a choke, specifically designed for use with motor drives.

It enhances system reliability by reducing harmonic currents generated by motor drives and providing improved protection against electrical disturbances.

The brand of this product is Schneider Electric.

It is suitable for industrial, manufacturing, automation, and HVAC motor control systems where minimizing electrical disturbances is critical.

The model number is VW3A4552.

It provides enhanced protection and improved drive performance, contributing to system longevity in industrial applications.

This choke is associated with the Altivar series.

Related Products

Other Products from this brand

$586.47
$568.88 Save 3%
Tax included
Quantity
Delivery Time Delivered within 0-3 days
  • Global Payments 140+ CountriesGlobal Payments 140+ Countries
  • Global Shipping Fedex/UPS/DHL/Aramex/
BlueDart/Delhivery/DP WorldGlobal Shipping Fedex/UPS/DHL/Aramex/ BlueDart/Delhivery/DP World
  • 24/7 Customer Support Email/Chat/Telephonic Support24/7 Customer Support Email/Chat/Telephonic Support
$586.47
$568.88
Tax included