Previous
Next
Share
Free Delivery in India | Lowest Global Shipping Charges
24/7 Customer Support
24/7 Customer Support

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

24/7 Customer Support
Save up to 28% with GST Input

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

Lowest Price Challenge
# Lowest Price Challenge

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Lowest Price Challenge
100% Original Products

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase

RIGOL High-Voltage Differential RP1025D Active Probe For DS1000Z-E Series

Category Test Probes Brand Rigol

Specifications

Country of Origin India
Brand Rigol
Applications Industrial, Laboratory, Development, Quality Control
Model RP1025D
Bandwidth 25 MHz
Probe type Differential Active Probe
Voltage Rating 1.3 kV
Form Factor Handheld Probe with Shielded Cable
Noise Rejection Active differential
Product Condition New
MPN RP1025D
Oscilloscope Compatibility DS70000, DS8000-R, MSO8000, MSO8000A, MSO5000, DHO900, DHO800, DH4000, DHO1000, DS1000Z, DS1000Z-E, MSO/DS7000 Series
Maximum Differential Voltage 1.3 kV

Key Features

Rigol RP1025D High-Voltage Differential Active Probe designed for precise high-voltage measurement and safe signal analysis in demanding environments.

  • Offers 25 MHz bandwidth for accurate signal capture.
  • Rated for 1.3 kV differential voltage, ensuring safety and reliability.
  • Active differential probe suited for precise noise rejection.
  • Optimized for industrial and laboratory testing applications.
  • Compatible with popular Rigol oscilloscopes such as DS70000, DS8000-R, MSO8000, and others.
  • Stable performance for high-voltage and fast transient signals.
  • Compact design with durable build quality.
  • Easy connection to test points in challenging environments.

Product Description

Rigol RP1025D is a high-voltage differential active probe engineered to deliver accurate measurement performance for signals up to 1.3 kV. Featuring a 25 MHz bandwidth, this probe is ideal for analyzing high-voltage, fast-changing signals in industrial, laboratory, and development environments.

  • 25 MHz bandwidth for high-fidelity signal measurement.
  • Supports a maximum differential voltage of up to 1.3 kV for safe operation with elevated voltage circuits.
  • Active differential design minimizes noise interference and enhances measurement precision.
  • Compatible with a wide range of Rigol oscilloscopes, including models DS70000 Series, DS8000-R Series, MSO8000/MSO8000A Series, MSO5000 Series, DHO900, DHO800, DH4000, DHO1000, DS1000Z, DS1000Z-E, and MSO/DS7000.
  • Rugged construction suitable for industrial, laboratory, and educational fields.
  • Optimized probe tip and shielding for effortless connection and low signal distortion.
  • Supports detailed signal investigation where safety and differential measurement are required.
  • Intended for use with high-voltage components, motor drives, power supplies, and inverter circuits.

This active probe ensures precision and operator protection, providing excellent noise rejection and signal clarity in demanding environments. Applications include industrial electronics, power systems diagnostics, research laboratories, and manufacturing quality control. Explore more Rigol test instrumentation and measurement solutions in the EnvMart catalog.

RIGOL High-Voltage Differential RP1025D Active Probe For DS1000Z-E Series
Looking to purchase in bulk?
  • Purchase item in bulk quantity
  • Get best price for your business

Comments (0)

No customer reviews for the moment.

Frequently Asked Questions

The Rigol RP1025D High-Voltage Differential Active Probe features a bandwidth of 25 MHz, allowing for high-fidelity signal measurement.

The RP1025D probe is rated for a maximum differential voltage of 1.3 kV, ensuring safe operation with high-voltage circuits.

The Rigol RP1025D is compatible with several Rigol oscilloscopes, including the DS70000 Series, DS8000-R Series, MSO8000/MSO8000A Series, MSO5000 Series, and DS1000Z-E among others.

The RP1025D is a differential active probe designed specifically for high-voltage measurements and precise signal analysis.

The Rigol RP1025D probe is optimized for use in industrial, laboratory, development, and quality control applications, making it versatile for various testing environments.

The active differential design of the RP1025D minimizes noise interference, which enhances measurement precision and ensures clearer signal analysis.

The RP1025D probe has a handheld form factor with a shielded cable, making it suitable for easy handling and connection in various environments.

The Rigol RP1025D probe features a rugged construction that is suitable for demanding industrial and laboratory environments, ensuring durability and reliability during use.

Related Products

Other Products from this brand

$806.05
$551.26 Save 31.61%
Tax included
Quantity
Delivery Time Delivered within 0-3 days
  • Global Payments 140+ CountriesGlobal Payments 140+ Countries
  • Global Shipping Fedex/UPS/DHL/Aramex/
BlueDart/Delhivery/DP WorldGlobal Shipping Fedex/UPS/DHL/Aramex/ BlueDart/Delhivery/DP World
  • 24/7 Customer Support Email/Chat/Telephonic Support24/7 Customer Support Email/Chat/Telephonic Support
$806.05
$551.26
Tax included