Previous
Next
Share
Free Delivery in India | Lowest Global Shipping Charges
24/7 Customer Support
24/7 Customer Support

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

24/7 Customer Support
Save up to 28% with GST Input

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

Lowest Price Challenge
# Lowest Price Challenge

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Lowest Price Challenge
100% Original Products

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase

Hanna ORP Analog Controller with Self-Diagnostic Test – HI8720

Category ORP Controllers Brand Hanna Condition New

Specifications

Country of Origin India
Power Supply 115 or 230 Vac, 50/60 Hz
Dimensions 141 x 69 mm
Environment -10 to 50 °C, RH max 95% non-condensing
mV Accuracy ±0.5%
mV Resolution 1 mV
mV Range ±1000 mV
Model HI8720
Alarm Relay Set Point 1, isolated, 2 A, Max 240 V, resistive load, 1000000 strokes
Enclosure Black anodized aluminum, ABS transparent splash-proof front cover
Weight 1 kg
Backlight Continuous ON
Product Condition New
MPN HI8720
Alarm Relay Range 10 to 300 mV
Analog Input Signal 4 to 20 mA
Analog Output Signal ±5 Vcc, 150 mA max load (amplified electrodes)
Over Dosing Control Adjustable, 5–60 min or disable by rear panel wire strap
mV (ORP) Calibration Offset: ±2 pH with OFFSET trimmer, Slope: 80–110% with SLOPE trimmer
mV (ORP) Dosing Relay 1, isolated, 2 A, Max 240 V, resistive load, 1000000 strokes
mV (ORP) Dosing Set Point 0.00 to 14.00 pH

Key Features

HI8720 ORP Analog Controller with Self-Diagnostic Test is ideal for panel mounting and industrial process control applications.

  • Features a built-in auto-diagnostic test for continuous electrode and instrument status monitoring.
  • Allows selection of set points for controlling oxidizing or reducing dosage operations.
  • Includes isolated alarm and dosing relay contacts for safety and process flexibility.
  • Displays measured ORP values clearly on an easy-to-read LCD display with continuous backlight.
  • Offers adjustable overdosing control from 5 to 60 minutes via a rear panel knob.
  • Equipped with a removable, transparent splash-proof cover protecting the front panel.
  • Supports analog input/output signals (4–20 mA, ±5 Vcc) suitable for process integration.
  • Robust housing combining black anodized aluminum and ABS front protection.
  • Operates within a wide environment range (-10 to 50 °C, up to 95% RH, non-condensing).

Product Description

HI8720 ORP Analog Controller with Self-Diagnostic Test is a high-performance instrument designed for precise monitoring and control of oxidation-reduction potential in industrial settings. Panel-mounted for integration into control systems, it offers advanced self-diagnostic features accessed via front panel keys, allowing users to identify and isolate malfunctions for uninterrupted operation.

The controller supports selection of oxidizing or reducing set points, with consent relay contacts enabling coordinated control when combined with pH controllers. Isolated alarm and dosing relays (2A, max 240V) ensure safe switching with high stroke durability. Continuous LCD backlighting guarantees visibility in any condition, while the adjustable overdosing control enhances process safety.

  • Built-in autodiagnostic functions for user-friendly troubleshooting and maintenance.
  • Selectable set points for oxidation/reduction dosage processes.
  • Isolated alarm relay and dosing relay contacts rated at 2A, max 240V.
  • Analog input and output signals: 4–20 mA and ±5 Vcc, 150 mA max load, suitable for amplified electrodes.
  • Robust enclosure: black anodized aluminum body with transparent ABS splash-proof front cover.
  • Operating environment: -10 to 50°C, RH max 95% non-condensing.
  • Overdosing control adjustable from 5 to 60 minutes, with disable option via wire strap.
  • LCD display with continuous backlight for clear measurement readout.
  • Calibration: offset and slope trimmers for precision adjustment.
  • Accurate ORP measurement range: ±1000 mV, 1 mV resolution, ±0.5% accuracy.

HI8720 suits applications in water treatment plants, chemical manufacturing, environmental laboratories, and industrial process automation where reliable ORP control is essential. The rugged housing ensures longevity in challenging industrial environments.

Browse more advanced industrial controllers, process instruments, and laboratory automation solutions in the EnvMart category to optimize your process monitoring setup.

Hanna ORP Analog Controller with Self-Diagnostic Test – HI8720
Looking to purchase in bulk?
  • Purchase item in bulk quantity
  • Get best price for your business

Comments (0)

Related Products

$856.78
$805.37 Save 6%
Tax included
Quantity
Delivery Time Delivered within 0-3 days
  • 100% Original & Genuine Products with Manufacturers Warranty 100% Original & Genuine Products with Manufacturers Warranty
  • 24/7 Customer Support Email/Chat/Telephonic Support 24/7 Customer Support Email/Chat/Telephonic Support
  • Fastest Global Shipping Fedex/UPS/DHL/Aramex/BlueDart/Delhivery Fastest Global Shipping Fedex/UPS/DHL/Aramex/BlueDart/Delhivery
$856.78
$805.37
Tax included