Hanna pH/EC/TDS Multiparameter Probe - HI1285-5

Specifications

Country of Origin India
Body Material polypropylene
Outer Diameter 16 mm
Model HI1285-5
Temperature Sensor yes
Cable 7-pole, 1 m (3.3 ft)
Connector Type DIN
Reference Cell Type Single, Ag/AgCl
Type of Electrolyte Polymer gel
Matching Pin no
Temperature Operating Range 0 to 50 °C
Amplifier yes
Glass Type low temperature (LT)
Optimum pH Range 0 to 13
Overall Length 185 mm
Junction Type Cloth
Maximum Pressure 0.1 bar
Body Length 95 mm
Parameters Measured pH, EC, TDS, Temperature
Product Condition New
MPN HI1285-5
Tip/Shape Spheric (8 mm)

Key Features

HI1285-5 Multiparameter pH/EC/TDS probe for integrated laboratory monitoring.

  • Measures pH, electrical conductivity (EC), total dissolved solids (TDS), and temperature in one body.
  • Polypropylene housing ensures chemical resistance and robust performance.
  • Cloth junction with polymer gel electrolyte is maintenance-free and provides reliable readings.
  • Built-in temperature sensor enables automatic temperature compensation for accurate analysis.
  • Ideal for greenhouses, hydroponics, environmental, boiler, and water treatment applications.
  • Features DIN connector and 1-meter cable for ease of use with compatible meters.
  • Low-temperature glass sensing bulb for accurate results from 0 to 50°C.
  • Maximum pressure tolerance up to 0.1 bar for a wide range of field and lab use.

Product Description

The HI1285-5 multiparameter probe offers reliable measurement of pH, EC (conductivity), TDS, and temperature within a single polypropylene body, making it a powerful tool for laboratory, industrial, and environmental monitoring. It features a cloth junction, maintenance-free gel electrolyte, and a low-temperature glass sensing bulb for superior analytical performance. Automatic temperature compensation is enabled via an integrated temperature sensor, ensuring your results are accurate regardless of changing conditions. The two stainless steel pins support precise EC/TDS readings using amperometric methods. With its DIN connector and flexible 1-meter cable, the HI1285-5 is simple to install and compatible with a wide range of laboratory meters.

  • Pre-amplified design supports sensitive measurements with reduced signal noise in active environments.
  • Durable polypropylene housing offers resistance to chemical corrosion and ensures a long operational life.
  • Spheric (8 mm) tip enhances contact area for quick, stable readings across 0 to 13 pH range.
  • Maximum pressure tolerance of 0.1 bar provides operational safety for water treatment and hydroponic systems.
  • Cloth junction with single reference Ag/AgCl cell for accurate and reliable reference potential.
  • Operating temperature range of 0 to 50°C supports a variety of field and laboratory conditions.
  • Recommended for continuous and batch measurements in greenhouses, hydroponics, environmental assessment, water treatment, and boiler or cooling tower monitoring.
  • Comes with a 1 m cable (7-pole) and pre-wired DIN connector for instant integration into compatible systems.

Applications extend to agricultural monitoring, process control, industrial water analysis, and educational laboratories. For more advanced laboratory sensors and a comprehensive selection of analytical instrumentation, explore the EnvMart Lab Equipment & Instruments category.

Comments (0)

Frequently Asked Questions

The HI1285-5 probe measures pH, electrical conductivity (EC), total dissolved solids (TDS), and temperature all in one unit.

The probe is made of durable polypropylene, which ensures chemical resistance and robust performance in various environments.

The built-in temperature sensor enables automatic temperature compensation, ensuring accurate readings regardless of temperature fluctuations.

The HI1285-5 probe has a maximum pressure tolerance of 0.1 bar, making it suitable for various field and lab applications.

Yes, the probe features a cloth junction with a polymer gel electrolyte that is maintenance-free and provides reliable readings.

The operating temperature range is from 0 to 50°C, making it versatile for various applications.

Yes, the HI1285-5 is ideal for hydroponics, as well as for greenhouses, environmental monitoring, and water treatment applications.

The probe features a DIN connector with a 1-meter cable for easy integration with compatible meters.

The HI1285-5 can measure pH levels in the range of 0 to 13, providing a wide scope for various applications.

You can purchase the HI1285-5 probe through our online store or contact us for further inquiries regarding availability.

Related Products

Other Products from this brand

$161.16
$156.33 Save 3%
Tax included
Quantity
Delivery Time Delivered within 0-3 days
  • Genuine Products   
  • Global Shipping 
  • Secured Payments
$161.16
$156.33
Tax included