Previous
Next
Share
Free Delivery in India | Lowest Global Shipping Charges
24/7 Customer Support
24/7 Customer Support

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

24/7 Customer Support
Save up to 28% with GST Input

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

Lowest Price Challenge
# Lowest Price Challenge

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Lowest Price Challenge
100% Original Products

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase

GroLine pH/EC/TDS Multiparameter Probe

Specifications

Country of Origin India
Brand Hanna
Body Material polypropylene
pH Range 0 to 13
Connection DIN
Model HI1285-8
Temperature Sensor yes
Cable 7-pole, 1 m cable
Amplifier yes
Recommended Use Hydroponics, aquaponics, greenhouses
Max Pressure 0.2 bar
Measurement Parameters pH, EC, TDS, Temperature
Electrolyte Gel
Reference Single, Ag/AgCl
Product Condition New
MPN HI1285-8
Tip/Shape Spheric (dia 8.5 mm)
Special Note To be used with HI981420 GroLine Monitor
Junction/Flow Rate Cloth
Recommended Operating Temperature 0 to 50 °C

Key Features

Hanna HI1285-8 pH/EC/TDS groline multiparameter probe is designed for hydroponics, aquaponics, and greenhouse monitoring.

  • Measures pH, EC (conductivity), TDS, and temperature with one probe.
  • Features a built-in temperature sensor for fast, accurate, and compensated readings.
  • Polypropylene body provides enhanced chemical resistance for long life in nutrient solutions.
  • Cloth junction and gel electrolyte extend durability and reduce maintenance requirements.
  • Pre-amplified pH electrode for reliable measurements, even in varying environments.
  • Specifically optimized for use with Hanna HI981420 GroLine monitor.
  • 1 m 7-pole cable with DIN connection for easy integration.
  • Recommended operating temperature from 0 to 50°C.

Product Description

Hanna HI1285-8 Multiparameter Probe is an advanced laboratory-grade sensor designed for simultaneous measurement of pH, electrical conductivity (EC), TDS, and temperature in hydroponic, aquaponic, and greenhouse nutrient solutions. The probe features a robust polypropylene body providing excellent chemical resistance, making it ideal for continuous monitoring applications.

This multiparameter sensor consolidates three essential water quality measurements into a single rugged probe, making it compatible with the Hanna GroLine HI981420 Monitor for seamless integration and operational ease. The built-in temperature sensor ensures fast, precise, and automatically compensated readings, even under rapid temperature changes. The renewable cloth junction and gel electrolyte configuration prolong probe life and minimize maintenance in harsh growing environments.

  • High-performance multiparameter probe for measuring pH, EC, TDS, and temperature.
  • Polypropylene body ensures chemical resistance.
  • Pre-amplified pH electrode enhances signal reliability in noisy environments.
  • Cloth, single Ag/AgCl reference junction for accuracy and durability.
  • Gel-type electrolyte for maintenance-free operation.
  • Supplied with a 7-pole, 1-meter cable and DIN connection.
  • Operating temperature range: 0 to 50°C (32 to 122°F).
  • For use in hydroponics, aquaponics, greenhouses, and agriculture laboratories.
  • Spheric tip (8.5 mm dia) for precise measurement.
  • Maximum pressure: 0.2 bar.

Industrial, laboratory, horticultural, and greenhouse professionals trust the HI1285-8 for its robust construction, repeatable accuracy, and user-focused design. Set includes one probe compatible with the HI981420 GroLine Monitor. Explore more Hanna instruments in the laboratory electrodes & sensors category on EnvMart.

Comments (0)

Frequently Asked Questions

The HI1285-8 probe can measure pH, electrical conductivity (EC), total dissolved solids (TDS), and temperature simultaneously.

Yes, the HI1285-8 is specifically designed for hydroponics, aquaponics, and greenhouse monitoring, making it ideal for these applications.

The recommended operating temperature range for the HI1285-8 is from 0 to 50°C (32 to 122°F).

The built-in temperature sensor provides fast and accurate readings, automatically compensating for temperature variations to ensure reliable measurements.

The probe features a polypropylene body that offers enhanced chemical resistance, making it durable for use in nutrient solutions.

The HI1285-8 uses a cloth junction with a gel electrolyte, which extends the probe's durability and reduces maintenance needs.

The HI1285-8 is optimized for use with the Hanna HI981420 GroLine monitor, but it may work with other compatible devices.

The HI1285-8 comes with a 1-meter long 7-pole cable with a DIN connection for easy integration.

The maximum pressure that the HI1285-8 can handle is 0.2 bar.

The HI1285-8 features a maintenance-free design due to its gel electrolyte and cloth junction, but regular calibration and proper storage are recommended for optimal performance.

Related Products

Other Products from this brand

$183.63
$178.12 Save 3%
Tax included
Quantity
Delivery Time Delivered within 0-3 days
  • Genuine Products   
  • Global Shipping 
  • Secured Payments
$183.63
$178.12
Tax included