Previous
Next
Share
Free Delivery in India | Lowest Global Shipping Charges
24/7 Customer Support
24/7 Customer Support

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

24/7 Customer Support
Save up to 28% with GST Input

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

Lowest Price Challenge
# Lowest Price Challenge

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Lowest Price Challenge
100% Original Products

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase

Hanna HI6000-2 (pH/ORP/ISE) module is designed to be used with the HI6000 Multiparameter Modular System

Category Multiparameter Brand Hanna

Specifications

Country of Origin India
Temperature Accuracy ±0.2 °C
Condition New
Temperature Resolution 0.1 °C
Product Type Multiparameter pH/ORP/ISE Measurement Module
Temperature range -20.0 to 120.0 °C
pH Range −2.000 to 20.000 pH
pH Resolution 0.1; 0.01; 0.001 pH
pH Accuracy ±0.1; ±0.01; ±0.002 pH (±1 LSD)
ORP Range −2000.0 to 2000.0 mV
ORP Resolution 0.1; 1 mV
ORP Accuracy ±0.2 mV; ±1 LSD
Temperature Compensation Automatic or Manual
ISE Range 1.0×10⁻⁵ to 300.0 ppt; 5.0×10⁻³ to 1.0×10⁵ ppm; 1.0 to 5.0×10⁷ ppb; 1.0×10⁻⁷ to 10.0 M; 1.0×10⁻⁴ to 1.0×10⁴ mmol/L; 1.0×10⁻⁶ to 60.0 %w/v; 5.0×10⁻⁷ to 5.0×10⁷ user
ISE Accuracy ±0.5% (monovalent ions); ±1% (divalent ions)
Model HI6000-2
Measurement Modes Direct, Auto-Hold, Known Addition, Known Subtraction, Analyte Addition, Analyte Subtraction
Calibration Points Up to 5 (pH/ISE)
Measurement Parameters pH, ORP (mV), Ion-Selective Electrode (ISE), Temperature
ISE Calibration Points Up to 5
Standard Buffers Hanna and NIST pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45
MPN HI6000-2
Compatible Probes pH: HI1131B and all Hanna BNC electrodes; Temperature: HI7662-TW

Key Features

HI6000-2 Multiparameter pH/ORP/ISE Measurement Module delivers high-precision laboratory grade measurements and automatic temperature compensation.

  • Measures pH, ORP, Ion-Selective Electrode (ISE), and temperature with advanced stability criteria.
  • Supports up to 5-point calibration and custom/group buffers for accurate operation.
  • Wide measurement ranges for pH (−2.000 to 20.000), mV (−2000.0 to 2000.0), and ISE (1.0×10⁻⁵ to 300.0 ppt; 1.0×10⁻⁷ to 10.0 M, etc.).
  • Provides direct/auto-hold, known addition/subtraction, and application-specific measurement profiles.
  • Automatic or manual temperature compensation and single-point temperature calibration.
  • Compatible with Hanna BNC pH electrodes, HI1131B, HI7662-TW, and various ion-selective electrodes.
  • Includes GLP, data logging, stability indicators, and multiple modes for industrial/lab traceability.
  • Audible alarms and calibration reliability ensure process security in industrial or research settings.

Product Description

HI6000-2 Multiparameter pH/ORP/ISE Measurement Module is designed for use with the HI6000 Modular Multiparameter System, enabling reliable measurement of pH, redox (ORP), and ion-selective electrode (ISE) parameters with integrated temperature compensation.

This advanced module offers robust performance for scientific, laboratory, industrial water quality, and environmental monitoring applications. It supports connection to all compatible Hanna pH electrodes with BNC connectors, and recommended probes include the HI1131B (pH) and HI7662-TW (temperature), as well as Hanna Ion Selective Electrodes.

  • Measures pH (−2.000 to 20.000), mV (−2000.0 to 2000.0), and ISE across a broad range, with accuracy down to ±1 last significant digit.
  • Automatic and manual temperature compensation is available (−20.0 to 120.0 °C), with high accuracy (±0.2 °C).
  • Multiple calibration types (up to 5 points) and buffer profiles (Hanna/NIST, custom, group) allow for flexible and precise calibration.
  • Application-specific profiles and advanced measurement modes (direct, auto-hold, known addition, subtraction, analyte addition/subtraction) streamline workflow efficiency.
  • Logging features, GLP traceability (Basic, Full, Simple, Table, and Graph views), and measurement stability indicators maximize process validation in research or manufacturing environments.
  • Audible/visual alarms, active log, and integrated calibration reminders enforce consistent quality control and equipment reliability.

This module is ideal for routine laboratory work, chemical analysis, water treatment monitoring, research, and process industry environments requiring flexible measurement of pH and ions. For more advanced analysis or automation, it integrates seamlessly with the HI6000 Modular System platform.

Browse more laboratory measuring modules and accessories in the EnvMart category for customized configurations.

Comments (0)

Frequently Asked Questions

The HI6000-2 module can measure pH, ORP (redox), Ion-Selective Electrode (ISE), and temperature.

The pH measurement range is from −2.000 to 20.000, and the ISE measurement range is from 1.0×10⁻⁵ to 300.0 ppt and 1.0×10⁻⁷ to 10.0 M.

Yes, it supports both automatic and manual temperature compensation ranging from −20.0 to 120.0 °C.

The HI6000-2 module supports up to 5-point calibration and various buffer profiles for accurate operation.

The module is compatible with Hanna BNC pH electrodes, including HI1131B and HI7662-TW, as well as various ion-selective electrodes.

The module includes GLP features such as data logging, stability indicators, and multiple modes for traceability in industrial or lab settings.

Yes, the HI6000-2 module includes audible and visual alarms to ensure process security and calibration reliability.

Yes, the HI6000-2 module is designed for use in industrial water quality monitoring, research, and other laboratory applications requiring high precision.

The pH measurements have an accuracy of ±1 last significant digit, while the temperature measurements have an accuracy of ±0.2 °C.

You can browse our EnvMart category for the HI6000-2 module and related accessories, or contact us for customized configurations.

Related Products

Other Products from this brand

$40.19
$38.98 Save 3%
Tax included
Quantity
Delivery Time Delivered within 0-3 days
  • Genuine Products   
  • Global Shipping 
  • Secured Payments
$40.19
$38.98
Tax included