Previous
Next
Share
Free Delivery in India | Lowest Global Shipping Charges
24/7 Customer Support
24/7 Customer Support

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

24/7 Customer Support
Save up to 28% with GST Input

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

Lowest Price Challenge
# Lowest Price Challenge

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Lowest Price Challenge
100% Original Products

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase

Hanna HI6000-3 Conductivity Module

Category Conductivity Meter Brand Hanna

Specifications

Country of Origin India
Temperature Accuracy ±0.2 °C; ±0.4 °F; ±0.2 K
Temperature range −20.0 to 120.0 °C; −4.0 to 248.0 °F; 253.2 to 393.2 K
TDS Range 0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt
TDS Accuracy ±1% of reading or ±0.01 ppm
Temperature Compensation Linear, Natural Standard, Disabled
Salinity Range 0.00 to 42.00 PSU; 0.00 to 80.00 ppt; 0.0 to 400.0 %
Model HI6000-3
Reference Temperature 5.0 to 30.0 °C (41.0 to 86.0 °F, 278.2 to 303.2 K)
Resistivity Range 1.0 to 99.9 Ω·cm; 100 to 999 Ω·cm; 1.00 to 9.99 kΩ·cm; 10.0 to 99.9 kΩ·cm; 100 to 999 kΩ·cm; 1.00 to 9.99 MΩ·cm; 10.0 to 100.0 MΩ·cm
Temperature Calibration Single point, adjustable
Measurement Modes Direct, Direct/Autohold, Direct/USP
Temperature Coefficient 0.00 to 10.00 %/°C
Cell Constant 0.0500 to 200.0000 /cm
Conductivity Accuracy ±1% of reading or ±0.010 μS/cm
Conductivity Range 0.000 to 9.999 μS/cm; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm
Salinity Accuracy ±1% of reading
Calibration Type Automatic, Manual
Resistivity Accuracy ±1% of reading or ±1 Ω·cm
Conductivity Calibration Points Single up to 5 points
GLP Features Simple and full GLP reporting, calibration points log, event logs, graphical and tabular views
Calibration Solutions 84 μS/cm, 1413 μS/cm, 5000 μS/cm, 12880 μS/cm, 80000 μS/cm, 111800 μS/cm
Measurement Types Conductivity, Resistivity, TDS, Salinity
Product Condition New
Resolution (Conductivity) 0.001/0.01/0.1 μS/cm; 0.001/0.01/0.1 mS/cm

Key Features

HI6000-3 Conductivity Module designed for the HI6000 Multiparameter Modular System, offering high-precision measurements across conductivity, resistivity, TDS, and salinity, tailored for laboratory and pharmaceutical water analysis.

  • Measures a wide range of parameters including conductivity (μS/cm, mS/cm), resistivity, TDS, and salinity.
  • Accuracy of ±1% of reading or ±0.010 μS/cm, whichever is greater.
  • Calibrates with single point up to five points and supports both automatic and manual calibration.
  • USP bulk water analysis support with guided compliance steps and out-of-specification notifications.
  • Temperature compensation options include Linear, Natural Standard, and Disabled modes.
  • Measurement modes: Direct, Direct/Autohold, and Direct/USP for conductivity-only applications.
  • Advanced reporting with GLP-compliant logs, event timelines, and table/graph views.

Product Description

HI6000-3 Conductivity Module delivers robust and reliable high-purity water analysis for laboratory, industrial, and pharmaceutical applications. Compatible with the HI6000 Multiparameter Modular System, it offers seamless plug-and-play installation, supporting versatile conductivity, resistivity, TDS, and salinity measurements. This module is engineered for environments where precise water quality management is critical, such as pharmaceutical production, meter verification, and cell validation scenarios.

  • Multiparameter measurement flexibility spanning conductivity (μS/cm, mS/cm), resistivity (Ω·cm, kΩ·cm, MΩ·cm), TDS (ppm, ppt), and salinity (ppt, PSU, %).
  • Conductivity range from 0.000 to 1000.0 mS/cm, ensuring suitability for diverse laboratory conditions.
  • Exceptional accuracy of ±1% of reading or ±0.010 μS/cm and five-point calibration using standard solutions for superior repeatability.
  • USP bulk water analysis enabled via software-guided procedures for compliance, with alerts for out-of-specification readings.
  • Temperature calibration is single-point and adjustable, with a broad temperature range from −20.0 to 120.0 °C, ensuring reliability in varied applications.
  • GLP-compliant: logs calibration, stability status, measurement history, and supports detailed graphical/tabular reviews.
  • Plug-and-play, effortless installation, and future-readiness with modular configuration for multiparameter expansion.
  • Ideal for use in pharmaceutical, laboratory, water treatment, and manufacturing environments requiring high reliability and traceable measurement data.

This conductivity module provides the data integrity, accuracy, and operational simplicity critical for compliant water quality monitoring in regulated sectors. Discover more industrial laboratory modules and accessories in EnvMart's Conductivity Meter section.

Comments (0)

Frequently Asked Questions

The HI6000-3 Conductivity Module can measure conductivity (μS/cm, mS/cm), resistivity (Ω·cm, kΩ·cm, MΩ·cm), TDS (ppm, ppt), and salinity (ppt, PSU, %).

The module has an accuracy of ±1% of reading or ±0.010 μS/cm, whichever is greater, ensuring reliable measurements.

The HI6000-3 supports single-point to five-point calibration and allows both automatic and manual calibration using standard solutions.

Yes, the module supports USP bulk water analysis with software-guided compliance steps and notifications for out-of-specification readings.

Temperature compensation options include Linear, Natural Standard, and Disabled modes, providing flexibility for various applications.

The module offers Direct, Direct/Autohold, and Direct/USP measurement modes for conductivity-only applications.

Yes, it is GLP-compliant, providing logs for calibration, stability status, and measurement history, along with graphical and tabular reviews.

The conductivity range of the HI6000-3 is from 0.000 to 1000.0 mS/cm, making it suitable for diverse laboratory conditions.

Yes, the HI6000-3 features a plug-and-play design for effortless installation, allowing for quick setup and use.

The HI6000-3 is ideal for pharmaceutical, laboratory, water treatment, and manufacturing environments that require high reliability and traceable data.