| Temperature Accuracy |
0.15 C| 0.27 F| 0.15 K |
| Display |
dot matrix |
| Brand |
Hanna |
| Dimensions |
185.0 x 93.0 x 35.2 mm (7.3 x 3.6 x 1.4) |
| Temperature Resolution |
0.01 C| 0.01 F| 0.01 K |
| Temperature range |
-5.00 to 55.00 C| 23.00 to 131.00 F| 268.15 to 328.15 K |
| pH Range |
0.00 to 14.00 pH |
| pH Resolution |
0.01 pH |
| pH Accuracy |
0.02 pH |
| Environment |
0 to 50 C (32 to 122 F)| RH 100% |
| pH Calibration |
automatic one| two| or three points of five standard buffers (pH 4.01| 6.86| 7.01| 9.18| 10.01) or one custom buffer |
| pH Temperature Compensation |
yes |
| Battery Type/Life |
1.5V AA batteries (4) / approximately 400 hours of continuous use without backlight (50 hours with backlight) |
| Automatic Shut-Off |
Not used (disabled)| 5| 10| 15| 20| 30| 60 minutes |
| Connectivity |
via USB-C with Hanna software |
| TDS Range |
0.0 to 200.0 ppt (g/L) (the maximum value depends on the TDS factor) |
| TDS Accuracy |
1% of reading or 1 ppm (mg/L) whichever is greater |
| TDS Resolution |
1 ppm (mg/L)| 0.001 ppt (g/L)| 0.01 ppt (g/L)| 0.1 ppt (g/L)| 1 ppt (g/L) |
| Ordering Information |
HI98199 is supplied with the HI829113 pH digital probe with 4m (13) cable| pH calibration solution sachets| PC software| micro USB cable| batteries| quality certificate| and instruction manual in a rugged carrying case. |
| EC Range |
0 to 200 mS/cm |
| EC Resolution |
1 S/cm| 0.001 mS/cm| 0.01 mS/cm| 0.1 mS/cm| 1 mS/cm |
| EC Accuracy |
1.5% of reading or 2 S/cm whichever is greater |
| EC Calibration |
automatic single-point| with six standard solutions (84 S/cm| 1413 S/cm| 5.00 mS/cm| 12.88 mS/cm| 80.0 mS/cm| 111.8 mS/cm) or custom point |
| TDS Calibration |
based on conductivity calibration |
| EC/TDS Temperature Compensation |
yes |
| Temperature Correction Coefficient |
0.00 to 6.00 %/C |
| EC to TDS Conversion Factor |
0.00 to 1.00 |
| Temperature Compensation |
automatic from -5 to 55 C (23 to 131 F) |
| Salinity (PSU) Range |
0.00 to 70.00 PSU |
| Salinity (PSU) Resolution |
0.01 PSU |
| Salinity (PSU) Accuracy |
2% of reading or 0.01 PSU whichever is greater |
| Cell Type |
four ring |
| mV Accuracy |
0.5 mV |
| mV Resolution |
0.1 mV |
| mV Range |
600.0 mV |
| Product Name |
Hanna | HI98199 | Multiparameter Portable pH/EC/DO Waterproof Meter |
| Logging Memory |
45000 records |
| Logging Type |
continuous logging or log-on-demand |
| GLP |
Yes |
| Calibration Timeout Reminder |
Yes |
| IP Protection |
IP67 |
| Reference Temperature |
25 C or 20 C |
| Logging Interval |
one second to three hours |
| Salinity Compensation |
yes |
| Dissolved Oxygen Range |
0.0 to 500.0%| 0.00 to 50.00 ppm (mg/L) |
| Dissolved Oxygen Resolution |
0.1%| 0.01 ppm (mg/L) |
| Dissolved Oxygen Accuracy |
0.0 to 300.0% |
| Dissolved Oxygen Temperature Compensation |
yes |
| Atmospheric Pressure Range |
450 to 850 mmHg| 17.72 to 33.46 in Hg 600.0 to 1133.2 mbar| 8.702 to 16.436 psi 0.5921 to 1.1184 atm| 60.00 to 113.32 kPa |
| Dissolved Oxygen Measurement Type |
galvanic |
| EC/TDS Multi-range Measurement Modes |
yes |
| Salinity (PSU) Calibration |
based on conductivity calibration |
| Salinity (Seawater Sigma) Range |
0.0 to 50.0 st| s0| s15 |
| Salinity (Seawater Sigma) Resolution |
0.1 st| s0| s15 |
| Salinity (Seawater Sigma) Accuracy |
1 st| s0| s15 |
| Salinity (Seawater Sigma) Calibration |
based on conductivity calibration |
| Resistivity Range |
0 to 999999 Ocm| 0 to 1000.0 kOcm| 0 to 1.0000 MOcm |
| Resistivity Resolution |
1 Ocm| 0.1 kOcm| 0.0001 MOcm |
| Resistivity Calibration |
based on conductivity calibration |
| Dissolved Oxygen Calibration |
automatic one or two points at 0| 100% or one custom point |
| Barometric Pressure Compensation |
yes |
| Temperature Calibration |
automatic at one custom point |
| Atmospheric Pressure Resolution |
0.1 mmHg| 0.01 in Hg| 0.1 mbar| 0.001 psi| 0.0001 atm| 0.01 kPa |
| Atmospheric Pressure Accuracy |
3 mmHg within 15 C from the temperature during calibration |
| Atmospheric Pressure Calibration |
automatic at one custom point |
| Weight |
400 g (14.2 oz.) |
Comments (0)
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent