Previous
Next
Share
Free Delivery in India | Lowest Global Shipping Charges
24/7 Customer Support
24/7 Customer Support

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

24/7 Customer Support
Save up to 28% with GST Input

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

Lowest Price Challenge
# Lowest Price Challenge

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Lowest Price Challenge
100% Original Products

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase

Labtronics LT-2204 Variable Double Beam Spectrophotometer Variable Bandwidth And 8 Cell Holder

SKU ABDBA Category Spectrophotometer Brand Labtronics

Specifications

Display Graphic LCD (320240 Dots)
Brand Labtronics
Dimensions 630 x 430 x 206 mm
Detector Silicon Photodiode
Model LT-2204
Wavelength Range 190 - 1100 nm
Wavelength Accuracy +- 0.3 nm
Optical System Double Beam Spectral
Stability 0.001A/h @ 500 nm
Wavelength Repeatability +- 0.2 nm
Photometric Range %T 0 - 200% Ab 0.3 to 3A Conc - 9999 C
Photometric Accuracy +- 0.3% T
Lamp Type Tungsten Halogen Lamp Deuterium Lamp
Baseline Flatness +- 0.001A/h
Bandwidth 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm (Variable)
Grating 1200 lines / mm
Photometric Repeatability + 0.2 % T

Key Features

  • Double Beam Optics
  • On-screen Standard and Kinetic Curve Display
  • Tungsten/Deuterium Lamp can be turned ON/OFF Individually to Extend Lifetime
  • Application Software provides complete control of the instrument from a computer through the built-in USB Port.

Product Description

LABTRONICS Variable Double Beam Spectrophotometer Variable Bandwidth And 8 Cell Holder (LT-2204), Variable Double Beam Spectrophotometer Device - WITH 8 CELL HOLDER offered comes with a wavelength range of 190-1100 nm (1200 Lines/mm grating) as well as Basic/Quantitative/Wavelength Scan/DNA Protein Test/Kinetics operational modes. For efficient performance, the system can deliver Fast / Medium / Slow scanning support as well as wavelength accuracy of +0.1 nm, a bandwidth of 0.5, 1,2,4,5, and wavelength reproducibility of 0.1 nm. Some of the other standard features of this system include photometric repeatability of + 0.2 % T, baseline flatness of + 0.001 A, USB-based data output port, and parallel printer port among others.
  • Basic, WL Scan, Multi-Wavelentgth, Kinetic, Quantitative, DNA/Protein modes

Comments (0)

Related Products

Recently Viewed Products

$4,593.55
$3,636.25 Save 20.84%
Tax included
Quantity
Delivery Time Delivered within 0-3 days
  • Genuine Products   
  • Global Shipping 
  • Secured Payments
Previous
Next
Share
Free Delivery in India | Lowest Global Shipping Charges
24/7 Customer Support
24/7 Customer Support

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

24/7 Customer Support
Save up to 28% with GST Input

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

Lowest Price Challenge
# Lowest Price Challenge

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Lowest Price Challenge
100% Original Products

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase

Labtronics LT-2204 Variable Double Beam Spectrophotometer Variable Bandwidth And 8 Cell Holder

SKU ABDBA Category Spectrophotometer Brand Labtronics

Specifications

Display Graphic LCD (320240 Dots)
Brand Labtronics
Dimensions 630 x 430 x 206 mm
Detector Silicon Photodiode
Model LT-2204
Wavelength Range 190 - 1100 nm
Wavelength Accuracy +- 0.3 nm
Optical System Double Beam Spectral
Stability 0.001A/h @ 500 nm
Wavelength Repeatability +- 0.2 nm
Photometric Range %T 0 - 200% Ab 0.3 to 3A Conc - 9999 C
Photometric Accuracy +- 0.3% T
Lamp Type Tungsten Halogen Lamp Deuterium Lamp
Baseline Flatness +- 0.001A/h
Bandwidth 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm (Variable)
Grating 1200 lines / mm
Photometric Repeatability + 0.2 % T

Key Features

  • Double Beam Optics
  • On-screen Standard and Kinetic Curve Display
  • Tungsten/Deuterium Lamp can be turned ON/OFF Individually to Extend Lifetime
  • Application Software provides complete control of the instrument from a computer through the built-in USB Port.

Product Description

LABTRONICS Variable Double Beam Spectrophotometer Variable Bandwidth And 8 Cell Holder (LT-2204), Variable Double Beam Spectrophotometer Device - WITH 8 CELL HOLDER offered comes with a wavelength range of 190-1100 nm (1200 Lines/mm grating) as well as Basic/Quantitative/Wavelength Scan/DNA Protein Test/Kinetics operational modes. For efficient performance, the system can deliver Fast / Medium / Slow scanning support as well as wavelength accuracy of +0.1 nm, a bandwidth of 0.5, 1,2,4,5, and wavelength reproducibility of 0.1 nm. Some of the other standard features of this system include photometric repeatability of + 0.2 % T, baseline flatness of + 0.001 A, USB-based data output port, and parallel printer port among others.
  • Basic, WL Scan, Multi-Wavelentgth, Kinetic, Quantitative, DNA/Protein modes

Comments (0)

Recently Viewed Products

$4,593.55
$3,636.25 Save 20.84%
Tax included
Quantity
Delivery Time Delivered within 0-3 days
  • Genuine Products   
  • Global Shipping 
  • Secured Payments
$4,593.55
$3,636.25
Tax included