| Resolution | Min 3 lines (279.5 & 279.8 peak and Valley ) |
|---|---|
| Brand | Shamboo scientific |
| Power | AC 220 V 10%| 50 Hz without sharp fluctuations. |
| Monochromator | Aberration Corrected Czerny-Turner |
| BACKGROUND CORRECTION | High speed self-reversal (BGC-SR) method High speed D2 lamp method (BGC-D2) |
| Gas Control | Automatic control & optimization flow/pressure) |
| Photometric Range | 0-125%| -0.1-3.00A |
| Bandwidth | 0.1|0.2|0.4|1nm(4 step auto switching) |
| Spray Chamber | Anticorrosion Material |
| Instrument Type | Single Beam Reflection Achromatic Optics System |
| Detection limit | (Cu) 0.004 g/ml max |
| Safety measures | Flame fuel gas| power assisted gas abnormal pressure protection Gas Leak check| prevention of gas release when flame dies out| prevention of flashback through pressure monitoring. |
| Working Temperature range | 10~300C |
| Concentration | standard curve| standard addition| interpolation |
| Dispersion elements | Grating system 1200 line/mm characterization area 40mm 2 Scintillation wavelength 250nm |
| WL Range | 190-900 |
| WL Accuracy | 0.2 |
| WL Repeatability | 0.1 nm max |
| HCL housing | Standard 4 lamp turret .( 1for measurement | 3 in warm-up mode) Option -6 Lamp / 8 Lamp Turret . |
| Static Baseline Drift | (Cu) +-0.003A/30min |
| Dynamic BaselineDrif | (Cu) +-0.006A/30min |
| Characteristic Concentration | (Cu) 0.025 g/ml max |
| Burner | Air cooled Titanium |
| Times of repetitive | Measurement 1-30 times| Average Value of A&C |
| Working Humidity range | 40%~85% |
Review sent
Your review cannot be sent

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase
| Resolution | Min 3 lines (279.5 & 279.8 peak and Valley ) |
|---|---|
| Brand | Shamboo scientific |
| Power | AC 220 V 10%| 50 Hz without sharp fluctuations. |
| Monochromator | Aberration Corrected Czerny-Turner |
| BACKGROUND CORRECTION | High speed self-reversal (BGC-SR) method High speed D2 lamp method (BGC-D2) |
| Gas Control | Automatic control & optimization flow/pressure) |
| Photometric Range | 0-125%| -0.1-3.00A |
| Bandwidth | 0.1|0.2|0.4|1nm(4 step auto switching) |
| Spray Chamber | Anticorrosion Material |
| Instrument Type | Single Beam Reflection Achromatic Optics System |
| Detection limit | (Cu) 0.004 g/ml max |
| Safety measures | Flame fuel gas| power assisted gas abnormal pressure protection Gas Leak check| prevention of gas release when flame dies out| prevention of flashback through pressure monitoring. |
| Working Temperature range | 10~300C |
| Concentration | standard curve| standard addition| interpolation |
| Dispersion elements | Grating system 1200 line/mm characterization area 40mm 2 Scintillation wavelength 250nm |
| WL Range | 190-900 |
| WL Accuracy | 0.2 |
| WL Repeatability | 0.1 nm max |
| HCL housing | Standard 4 lamp turret .( 1for measurement | 3 in warm-up mode) Option -6 Lamp / 8 Lamp Turret . |
| Static Baseline Drift | (Cu) +-0.003A/30min |
| Dynamic BaselineDrif | (Cu) +-0.006A/30min |
| Characteristic Concentration | (Cu) 0.025 g/ml max |
| Burner | Air cooled Titanium |
| Times of repetitive | Measurement 1-30 times| Average Value of A&C |
| Working Humidity range | 40%~85% |