Calibration Solutions
₹10,461
Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase
Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases
Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries
Brand | Hanna |
---|---|
Model | HI84529 |
Weight | 1.9 kg (67.0 oz.) |
Dimensions | 235 x 200 x 150 mm (9.2 x 7.9 x 5.9) |
Temperature range | -20.0 to 120.0C| -4.0 to 248.0F| 253.2 to 393.2 K |
Power Supply | 12 VDC adapter (included) |
Temperature Accuracy | 0.4C| 0.8F| 0.4 K (@25C/77F)| without probe error |
pH Range | -2.0 to 16.0 pH| -2.00 to 16.00 pH |
pH Resolution | 0.1 pH / 0.01 pH |
pH Accuracy | 0.01 pH (@25C/77F) |
Temperature Resolution | 0.1C| 0.1F| 0.1K |
Connectivity | 1 USB port for data storage and export to a PC |
Sample Size | LR 20 |
Environment | 0 to 50C (32 to 122F)| RH max 95% non-condensing |
Logging Memory | up to 400 ( 200 titrations| 200 pH/mV readings) |
pH Calibration | one| two or three-point calibration| four available buffers (4.01| 6.00| 8.30| 10.01) |
pH Temperature Compensation | manual or automatic |
pH Electrode | FC260B pH electrode with 1 m (3.3) cable (included)| HI5315 reference electrode with 1 m (3.3) cable (included) |
Ordering Information | HI84529-01 is supplied with FC260B pH electrode| HI5315 reference electrode| HI7662-M temperature probe| HI84529-50 low range 20 titrant (120 mL)| HI84529-52 low range 50 titrant (120 mL)| HI84529-51 high range 20 titrant (120 mL)| HI84529-55 calibration standard (230 mL)| HI7072 fill solution (30 mL)| HI700640 cleaning solution for milk deposits (2 x 20 mL)| capillary dropper pipette| 100 mL beakers (2)| dosing pump valve| 5 mL syringe| 1 mL plastic pipette| tube set (aspiration tube with titrant bottle cap and dispensing tube with tip)| stir bar| 12VDC power adapter| instruction manual and quality certificate. |
Logging Type | Log-on-demand |
Temperature Probe | HI7662-M temperature probe with 1 m (3.3) cable (included) |
pH-mV Range | -2000.0 to 2000.0 mV |
pH-mV Resolution | 0.1 mV |
pH-mV Accuracy | 1.0 mV |
Titration Method | acid base titration |
Titration Principle | endpoint titration| adjustable (pH 8.0 - 8.7 in 0.1 increments) |
Titration Range | Low Range |
Titration Resolution | Low Range |
Titration Accuracy | Low Range |
Titration Pump Speed | 10 mL/min |
Built-in Magentic Stirrer | Built-in magnetic stirrer at 800 rpm (Low Range) / 1000 rpm (High Range) |
check_circle