Previous
Next
Share
Free Delivery in India | Lowest Global Shipping Charges
24/7 Customer Support
24/7 Customer Support

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

24/7 Customer Support
Save up to 28% with GST Input

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases. And 0% Taxes on all worldwide deliveries

Lowest Price Challenge
# Lowest Price Challenge

If you find this product anywhere at lower cost than us. Call us and we will not only match the price but also give a complimentary coupon

Lowest Price Challenge
100% Original Products

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase

Gasoline Oxidation Stability Tester LOST-D13 EOST-D13

SKU ADGUQ Category Petroleum Testing Equipment Brand Generic Brand Condition New

Specifications

Country of Origin UK
Accuracy ±2 KPa
Display 10.1 inch color touch LCD display
Relative Humidity ≤85%
Brand Generic Brand
Design Integrated
Type Compact | Desktop
Model LOST-D13
Work Mode Automatic
Weight 25 kg (approx)
Ambient Temperature (ºC) ≤ 30°C
Type of Product Petroleum Testing Equipment
Heating Power 1600 W (automatically controlled by IPC)
Bath Metal bath (without water usage)
Operation System Windows
Dimension (W×D×H) 380×470×320 mm (without test barrel) | 380×470×600 mm (with test barrel)
Thermometer Mercury-in glass thermometer / can correct coefficient as need
Temperature control point of metal bath 100°C ± 1°C
IPC Built-in
Sample testing Parallel
Oxygen bomb assembly Unit body designed
Measuring range of oxygen bomb pressure transmitter 0 to 1600 KPa
Curve/graph Real time

Key Features

  • Compact, desktop structured instrument with integrated design
  • Built-in IPC, automation work mode, 10.1 inch color touch LCD display, Windows operation system
  • Double holes design to test two samples at the same time; parallel testing
  • Well-designed heat preservation system for energy saving as well as prevent operator from scalding
  • Unit-body designed bomb assembly, shorts the pressure testing pipe and makes the pressure determination more accurate
  • Bomb being well sealed to make the test result more reliable
  • Oxygen bomb location hole design, convenient for operator to disassemble the cover of oxygen bomb in holes, and easy to put the oxygen bomb during the test
  • Color LCD real-time display the two bomb test curve chart, two bombs comparative curve chart, time and pressure etc. relative data
  • Automatic change in curved time graph as per curve real time length ( maximum: 3000 min)
  • Wide application and direct reading test results
  • High automatic software design for automatic operation; User-friendly interface

Product Description

Gasoline Oxidation Stability Tester LOST-D13 is a compact, desktop instrument. Features integrated design having test part and control part united as one, bomb assembly as unit body design and oxygen bomb location hole design makes it convenient for operation. Equipped with built-in IPC, automation work mode, 10.1 inch color touch LCD display, Windows operation system ensures good outlook and convenient operating. Designed with double holes for parallel testing, heat preservation system for energy saving and high automatic software for hassle free running, metal bath without water usage and mercury-in glass thermometer, it is suitable to determine the oxidation stability of gasoline.

Applications:

Gasoline oxidation stability testers utilized in the petrochemical, biochemical materials, food science, and other industries for determination of the oxidation stability of gasoline.

Standard Accessories:

  • Oxygen bomb test assembly × 2
  • Glass mercury thermometers 95 to 103℃ ×1
  • Fuse 15A ×1
  • Stainless steel test hole cover ×2
  • Glass test bottle and cover ×4
  • O type sealing ring ×10
  • Thermometer frame ×1
Gasoline Oxidation Stability Tester LOST-D13 EOST-D13
Looking to purchase in bulk?
  • Purchase item in bulk quantity
  • Get best price for your business

Comments (0)

No customer reviews for the moment.

Frequently Asked Questions

The accuracy of this model is ±2 KPa.

The measuring range of the oxygen bomb pressure transmitter is from 0 to 1600 KPa.

It features a 10.1 inch color touch LCD display.

The ambient temperature should be ≤ 30°C for proper operation.

The heating power is 1600 W and is automatically controlled by the built-in IPC.

The dimensions are 380×470×320 mm without the test barrel and 380×470×600 mm with the test barrel.

It uses a metal bath without water usage.

It is designed for parallel testing with double holes to test two samples simultaneously.

The relative humidity should be ≤85% for optimal performance.

The country of origin for this model is the UK.

It includes a mercury-in-glass thermometer that can correct the coefficient as needed.

It operates on a Windows operating system, ensuring user-friendly interface and high automation.

Related Products

$69.50
Tax included
Quantity
Delivery Time Delivered within 0-3 days
  • Global Payments 140+ CountriesGlobal Payments 140+ Countries
  • Global Shipping Fedex/UPS/DHL/Aramex/
BlueDart/Delhivery/DP WorldGlobal Shipping Fedex/UPS/DHL/Aramex/ BlueDart/Delhivery/DP World
  • 24/7 Customer Support Email/Chat/Telephonic Support24/7 Customer Support Email/Chat/Telephonic Support
$69.50
Tax included