Serinus 31 Carbon Dioxide (CO2) Analyser
Quantity
Specifications
Country of Origin | India |
---|---|
Warranty | As per Manufacturer |
Key Features
- Extended measurement ranges
- External AC powered pump (capable of operating 3 analysers, excluding NOX)
- Internal long life, low power maintenance free pump (Max 6 watts)
- Dual filter (particulate), High pressure zero/span valves, Rack slides
- TCP/IP network port •
Product Details
The Serinus 31 carbon dioxide (CO2) analyser uses non-dispersive infrared (IR) gas correlation spectroscopy to provide accurate, stable, and repeatable measurements of gaseous CO2.The Serinus 31 can be configured to operate in absolute or differential mode providing flexibility within the analyser, making it well suited for ambient CO2 measurements in addition to applications such as dilution extractive stack monitoring.APPROVALSSimilar in design to the Serinus 30 Carbon Monoxide analyser,this instrument has the following approvals: US EPA approval (RFCA0509174) EN approval (TV 936/21221977/D) Non Dispersive I.R. Spectrometry method EN1426 Russian approval (56262-14) French approval LSCQA Ukraine approval (12/3/B/24/295-17) Chinese Pattern Approval (JJF1364-2012) Korean approval NIER (AACMS-2017-02)BENEFITSThe Serinus range of analysers has been designed using ourexperience and knowledge gained from operating large airquality monitoring networks for nearly 50 years. The resultis instruments that integrate seamlessly into continuousmonitoring networks. Guaranteed performance with a 2 year warranty Superior remote instrument control, diagnostic viewing &calibration minimise on-site maintenance requirements Comprehensive data logging & remote viewing of over 200operational parameters Versatile interfacing through RS232, USB, Bluetooth, analog &digital I/O & optional TCP/IP Easier setup through an intuitive menu system with QuickMenu, advanced GUI & a large keypad with tactile keys Instant display of operational status using illuminated trafficlights on the front panel Removable flash memory stores 10 years of data, includingup to 12 individual parameters & event logs. Operationalparameters can also be transferred to memory for easyretrieval Install latest firmware updates via the USB flash memory drive Easily program, view, download & email data using Bluetoothconnectivity combined with the Serinus Remote app from theGoogle Play store 12 VDC internal voltages for enhanced operator safety Standard components across the Serinus range reduces thecost of spare parts, accessories & consumables Rack slide design makes accessing internal components &removing the analyser from a rack cabinet easy Choose either an external sample pump suitable for use bymultiple analysers or the optional low power internal pump forgreater sample versatility Lower power demand & ability to operate over a widetemperature range reduce AQMS power usage.DATA LOGGING 8 GB removable USB flash memory drive that stores the internaldata logger, event log, automatic/manual configuration backupand automatic/manual parameter list save Internal data logger (can log up to 12 of 200+ parameters) Logger interval (1 second to 24 hours) Storage capacity ~ 10 years (set to 1 minute interval).OPTIONS & ACCESSORIES Internal Sample Dryer TCP/IP Network Port Dual Sample (particulate) Filter High Pressure Span (for direct cylinder calibration) High Pressure Zero (for direct cylinder calibration) Test Lamp (for PMT diagnostics) Metric Fitting Kit (to connect 6 mm tube to rear ports) 19 Rack Mount Kit External Pump (240 or 110 VAC) External Charcoal Scrubber Annual Maintenance Kit Trace Level Option High Level Option Printed User Manual (a soft copy of the user manual is supplied onthe ACOEM Ecotech resources USB stick with each analyser).COMMUNICATION #1 RS232 port (supports all protocols*) #2 RS232 port (supports all protocols* and multidrop) USB port (Advanced protocol only) Bluetooth (Advanced protocol only) TCP/IP network port (optional, supports all protocols*).*Available protocols: Modbus (RTU/TCP), Bayern Hessen, EC9800 or AdvancedCOMMUNICATION ANALOG & DIGITAL I/O PORT: 3 x analog outputs (current or voltage), 12 bit resolution userdefinable range (between two user specified points)Current range: 0 - 20 mA, 2 - 20 mA or 4 - 20 mAVoltage range: 0 - 5 V, 0 - 10 V (voltage offset of 0 V, 0.25 V or 0.5 V) 3 x analog inputs (scalable), 0 - 5 V, 16 bit resolution 8 x logic level digital control inputs 8 x open collector digital status outputs.
- Printed manual – electronic manual supplied with analyser
- Bluetooth connectivity combined with the Ecotech Serinus® Remote Android App makes it even easier to program, maintain, download and email data without touching the instrument.