Previous
Next

100% Original Products

Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase

Save up to 28% with GST Input

Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases

24/7 Customer Support

Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries

  • Genuine Products
  • Global Shipping
  • Secured Payments
In Stock
compare Compare

Combination Fire & Smoke Damper Model FSD-A-U

₹1
Tax included
Quantity

Specifications

Blade Type Triple V Type Parallel Configuration
Sleeve Factory Fitte inimum 432mm long 20Ga 180 GSM Galvanized Steel sheet
Frame Type Hat Channel 123mm wide
Frame MOC Galvanized Steel 16Ga 180 GSM
Blade MOC Galvanized Steel 16Ga 180 GSM
Top & Bottom Blade stopper 1mm thick 180 GSM Galvanized Steel
Axle Bush Bronze Bush pressed into Frame
Blade Axle (Shaft) MOC Zinc Plated Steel 9.5mm Square Bar
Linkage Tie Bar In Frame
Linkage MOC 3mm Galvanized Steel Tie Bar
Jamb Seals Stainless Steel Flexible Metal Compression Type
Resettable Thermal Release Device (RTR) Resettable Thermal Device operates at 74 C.
Damper Open/Close Switch (OCS) Damper Open/Close Indicator is mechanically linked to the blade to provide fool proof Open/Close readings.
Actuator UL Classified Actuator (24V Standard) / 230V Optional
Single Section 1220mm (H) x 914mm(W) (Maximum) 152mm H x 203mm W (Minimum)

Key Features

  • Smoke damper frame is of 180GSM galvanized steel of 16Ga thickness formed into a structural hat channel in 4-piece construction with integral overlapping gusset reinforcements (screws are not acceptable) in each corner to ensure perfect square shape. Top and Bottom frame members will be of low profile design to maximize the free area on small dampers less then 425mm height and hence minimize pressure drop.
Reference ACFSV Category Air Damper

Product Details

Smoke Damper are provided with an hourly fire rating. Smoke damper's primary function is to control the movement of smoke in dynamic air distribution systems Model FSD-A-U is a UL555 & UL555S classified multi blade Combination Fire & Smoke Damper with 3V style Blades. It is designed for closure/opening of the HVAC duct in Fire & Smoke situations. It is UL555 Classified to withstand fire conditions for 1.5 hours and is Class III Leakage Rated under UL555S at Elevated Temp of 350 F Model FSD-A-U can be installed vertically, with blades running horizontally with air flow in either direction.
  • 220v/24v step down transformer
  • Open/Close indication light
  • Power-On Indication light
  • Test Button
  • Aux Contact Points

Recommended products