Gas Analyzer
100% Original Products
Shop with assurance, as each product we offer is 100% original, ensuring quality and authenticity with every purchase
Save up to 28% with GST Input
Avail maximum benefits from input tax mechanism on all your Business Invoices. Get GST Invoices on your business purchases
24/7 Customer Support
Shop with confidence knowing that our 24/7 Customer Support is always available to assist with any inquiries
- Genuine Products
- Global Shipping
- Secured Payments
Serinus Cal 3000
Quantity
Specifications
Weight | 23.8 kg |
---|---|
Range | 0-20 ppm |
Operating voltage | 100 - 240 V VAC 50 / 60 Hz (autoranging) |
Repeatability | Less Than 1 % short term (24 hours) 5 % long term at constant temperature & humidity |
Power Consumption | 165 VA maximum (typical at start-up) 95 VA after warm-up |
Response time | 30 seconds to 95 % Less Than 5 seconds |
Pressure | Maximum altitude 3000 m above sea level |
Linearity | Less Than 1 % of full scale Within 0.15 % of full scale |
Flow Rate | Variable dependent on Dilution Mass Flow Controller installed |
Zero drift | Less Than 0.6 % per year Temperature 1.0 ppb per C 24 hours Less Than 0.3 ppb 7 days Less Than 0.3 ppb |
Dilution gas inputs | 1 standard 100 - 200 kPa (g) (2 optional) |
Source gas inputs | 4 standard 100 - 200 kPa (g) (8 optional) |
Dilution mass flow controller | 10 SLPM 0 Deg 1 ATM (std) 1 SLPM 2 SLPM 5 SLPM or 20 SLPM (optional) 2nd MFC (optional) |
Source mass flow controller | 50 SCCM 0 Deg 1 ATM (std) 10 SCCM 20 SCCM 100 SCCM 500 SCCM or 1 SLPM 2 SLPM (optional) 2nd MFC (optional) |
Flow accuracy (constant temp) | Within 1 % of full scale |
Flow repeatability | Within 0.15 % of full scale |
Operating gas pressure | 100 - 200 kPa |
Output manifold | 4 output ports standard |
Dilution ratio | Variable 10 1 to 2000 1 (std configuration) |
Case dimensions rack length | 597 mm (23.5 inch) (front to rear) |
Total length (with latch release) | 638 mm (25.1 inch) |
Chassis width | 418 mm (16.5 inch) |
Front panel width | 429 mm (16.9 inch) |
Chassis height | 163 mm / uses 4RU (6.4 inch) |
Front panel height | 175 mm (6.9 inch) |
Operating conditions ambient temperature range | 0 - 45 C (32 - 104 F) 20 - 35 C for optimum performance |
Output concentration | 3 ppb to 5000 ppb |
Precision | 0.5 ppb or 0.2 % of reading whichever is greater |
Noise at zero | Less Than 0.25 ppb |
Span drift | Temperature 0.1 % per C 7 days 0.5 % of reading |
Key Features
- New Serinus Cal user interface makes all functions simple and intuitive
- In-built photometer and ozone generator for use as a Level 3 ozone transfer standard
Product Details
The Serinus Cal 3000 includes all the features from its Serinus Cal 1000 and Serinus Cal 2000 stablemates, adding an ozone photometer for the accurate creation and delivery of ozone concentrations when calibrating ozone analyzers. The photometer accurately and continuously measures the ozone concentration to control output of the internal ozone generator, providing an accurate ozone source for routine ozone calibration.
- Ozone photometer based on the reliable and proven technology used in the Serinus 10 gas analyser
Recommended products
Gas Analyzer
Gas Analyzer
Gas Analyzer
Gas Analyzer